Catalog: Current Catalog
Company/Brand: Moeller Electric USA
|
| | 03/033 system pkz 2-sp self-protected combination ... starter without trip module 10 15 30 25 pkz2/s-sp full voltage reversing starter ... without trip module 10 15 30 25 pkz2/s-sp-fvr supplied with factory ... motor flc 1 1 3 1 1 2 0.4 0.6 1 2 5-8 8 14 14 -22 20 35 35 55 50 80 80 140 ... 130 220 200 350 275 425 350 500 zm-0.6-pkz2 024232 zm-1-pkz2 028979 zm-1.6-pkz2 ... 031352 zm-2.4-pkz2 033725 zm-4-pkz2 036098 zm-6-pkz2 038471 zm-10-pkz2 ... 040844 zm-16-pkz2 043217 zm-25-pkz2 045590 zm-32-pkz2 047963 zm-40-pkz2 ... 050336 zmr-0.6-pkz2 033943 zmr-1-pkz2 033950 zmr-1.6-pkz2 033952 zmr-2.4-pkz2 ... 033955 zmr-4-pkz2 033957 zmr-6-pkz2 033966 zmr-10-pkz2 033967 zmr-16-pkz2 ...
|
| | protector combinations overview system pkz 2 basic devices manual motor protector ... modules 10 signals on/off status of pkz 2/zm motor protector and pkz 2/zm s ... short-circuit current rating of the pkz 2/zm up to 100 ka 500 v ac for iec en ... applications plugs directly into the pkz 2/zm or can be mounted separately a ... plugs into the load side of the pkz 2/zm protector or can be mounted separately ... with 4th neutral pole rated 20 kw 400/415 v ac iec 60 947-4-1 rated for type ... plugs into the load side of the pkz 2/zm protector to create pkz 2/zm s magnetic ... trip module mounts on the side of the pkz 2/zm motor protector a page 08/032 ... remote control drive electrically turns pkz 2/zm motor protector on and off ...
|
| | motor protector combinations system pkz 2 ul csa iec ce manual motor ... motor protector combinations system pkz 2 type article no coil voltages shown ... ,6 1 1 1,6 1,6 2,4 2,4 4 46 58 8 14 14 22 20 35 35 55 50 80 ... 80 140 130 220 200 350 275 425 350 ... 6 10 10 16 16 27 24 32 32 42 pkz2/zm-0,6 021859 pkz2/zm-1 026605 pkz2/zm- ... 1,6 028978 pkz2/zm-2,4 031351 pkz2/zm-4 033724 pkz2/zm-6 036097 pkz2/zm-10 ... 038470 pkz2/zm-16 040843 pkz2/zm-25 043216 pkz2/zm-32 045589 pkz2/zm-40 ... 047962 pkz2/zm-0,6/s120v60hz 063460 pkz2/zm-1/s120v60hz 063470 pkz2/zm-1,6/ ... s120v60hz 063480 pkz2/zm-2,4/s120v60hz 063490 pkz2/zm-4/s120v60hz ... 063500 pkz2/zm-6/s120v60hz 063510 pkz2/zm-10/s120v60hz 063520 pkz2/zm-16/s120v60hz ...
|
| | 08/029 system pkz 2 motor protectors motor protective ... range of adjustable magnetic trips a 58 8 14 14 22 20 35 35 55 50 80 ... 80 140 130 220 200 350 275 425 350 ... 500 58 8 14 14 22 20 35 35 55 50 80 80 ... 130 220 200 350 275 425 350 500 zm-0,6-pkz2 024232 zm-1-pkz2 028979 zm-1,6-pkz2 ... 031352 zm-2,4-pkz2 033725 zm-4-pkz2 036098 zm-6-pkz2 038471 zm-10-pkz2 ... 040844 zm-16-pkz2 043217 zm-25-pkz2 045590 zm-32-pkz2 047963 zm-40-pkz2 ... 050336 zmr-0,6-pkz2 033943 zmr-1-pkz2 033950 zmr-1,6-pkz2 033952 zmr-2,4-pkz2 ... 033955 zmr-4-pkz2 033957 zmr-6-pkz2 033966 zmr-10-pkz2 033967 zmr-16-pkz2 ... 033968 zmr-25-pkz2 033969 zmr-32-pkz2 033973 zmr-40-pkz2 033975 type list ...
|
| | 08/042 system pkz 2 motor protectors control panel busbar ... with 60 mm phase separation pkz2/zm 40 8 pkz2/zm s without accessories pkz2/zm ... pkz2/zm s with all possible accessories 40 8 72 ... with 60 mm phase separation pkz2/zm 40 8 72 pkz2/zm s without accessories pkz2 ... /zm pkz2/zm s with all possible accessories 40 8 ...
|
| | 08/059 pkz0 motor protectors tripping ... manual motor protectors Îd 100 [ka pkz2/zm 8 80 pkz2/zm 8 se1a 60 40 30 2 ·i cc ... [a s 2 dt 106 8 6 4 3 2 1.5 -wa ve pkz 2/zm 8 pkz 2/zm 8 se1a 1 st half 32/40 ... a 25 a 16 a 10 a 20 15 10 8 6 4 3 2 1.5 u e 400 v 32/40 a 25 a 16 ... a 10 a 105 8 6 4 3 6a 2 1.5 104 8 6 e 6a 400 v 1 1 1.5 2 3 4 6 8 10 15 ... 20 30 40 60 80 100 i cc rms [ka 4 1 1.5 2 3 4 6 8 10 ... 15 20 30 40 60 80 100 ccrms [ka let-through current ... motor protector combinations 2 6 dt 10 8 100 80 60 40 [ka 6 1 st 4 30 2 ·i cc 3 ... 2 32/40 a 25 a 16 a 10 a 1,5 10 5 8 6 4 20 15 10 8 6 4 3 2 1.5 u e 400 v ... half -wa ve pkz2/zm 8 s pkz2/zm 8 s-g pkz2/zm 8 cl pkz2/zm s-sp [a s 2 pkz 2/zm 8 ...
|
| | 08/060 pkz 2 manual motor protectors technical ... to iec 60 068-2-30 -25 70 -25 60 -25 40 90 ° pkz 2 pkz 2 s pkz 2 cl pkz 2 s ... mounting position 90 ° 30° pkz 2 90° 90° s cl pkz 2 pkz 2 cl ° 90 s ... 30 2000 motor protector combination 8 1 x 1 16 or 2 x 1 6 1 x 1,5 10 or ... 2 x 1,5 6 14 6 1,8 1,0 v v ac a hz w ops 6000 iii/3 690 40 ... motor protector 60 max 690 max 250 max 40 pkz2/zm 30 50 2 0,5 6 electrical max ... residual error magnetic trip tolerance zm pkz2 zmr pkz2 motor-protective trip ... range single-phasing sensitivity pkz2/zm s cl 50 65 2 0,5 4 ka ka ca ms ca ms ca ... min max min max °c °c k x iu x iu -5 40 -25 60 0,25 g20 0,6 1,0 8,5 14 ul ...
|
| | 08/065 pkz 2 manual motor protectors technical ... .5 3 4 7.5 13.5 22 22 30 kw 0.25 0.37 0.8 1.1 2.2 3 5.5 10 15 22 24 0.25 0.37 0.8 ... manual motor protector 1-phase hp pkz2/zm-1.6 pkz2/zm-2.4 pkz2/zm-4 pkz2/zm-6 ... pkz2/zm-10 pkz2/zm-16 pkz2/zm-25 pkz2/zm-32 pkz2/zm-40 s-pkz2 115 v ac 1 1 1 8 4 2 ... 200 v ac 1 1 1 8 4 2 230 v ac 1 10 1 6 1 3 1 2 1 1/2 ... v 230 v 240 v kw 0.09 0.18 0.25 0.37 0.8 1.5 2.5 4 5.5 7.5 11 0.09 0.18 0.25 0. ... 37 0.8 1.5 2.5 4 5.5 7.5 11 380 v 400 v 415 v kw 0.12 0.25 0.55 0.8 1.5 2.5 4 ... 7.5 12.5 15 20 0.12 0.25 0.55 0.8 1.5 2.5 4 7.5 12.5 15 20 440 v manual ... motor protector contactor combination pkz2/zm-0.6 pkz2/zm-1 pkz2/zm-1.6 pkz2/zm-2. ...
|