tripping characteristics moeller faz-nart branch circuit breakers are available with c and d tripping characteristics c-curve devices are suitable for applications where medium levels of inrush current are expected applications include small transformers lighting pilot devices control circuits and coils c-curve devices provide a medium magnetic trip point devices with a d curve are suitable for applications where high levels of inrush current are expected the high magnetic trip point prevents nuisance tripping in high inductive applications such as motors transformers and power supplies even though not required by nec or cec for branch circuit breakers moeller s faz-nart devices are current limiting which means they interrupt fault currents within one half cycle of the fault current limiting devices offer superior protection by reducing peak letthrough current and energy 7200 3600 1200 600 2 2 1 1 tripping characteristic acc to ul 489 csa 22.2 no 235 conventional non-tripping cu
|
faz branch circuit breakers accessories bus bar system bus bar number of poles per device 1 number of terminals 6 12 18 6 rated operational current a 80 a type z-sv/ul-16/1p-1te/6 z-sv/ul-16/1p-1te/12 z-sv/ul-16/1p-1te/18 z-sv/ul-16/2p-2te/6 price 2 12 18 6 80a z-sv/ul-16/2p-2te/12 z-sv/ul-16/2p-2te/18 z-sv/ul-16/3p-3te/6 see green pages 3 12 18 80a z-sv/ul-16/3p-3te/12 z-sv/ul-16/3p-3te/18 contact your moeller representative for availability incoming supply terminals terminal description type price extension terminal accommodates conductors up to 25 mm2 awg 4 finger-safe connection z-ek-35/ul see green pages bus connector for conductors up to 50 mm2 awg 1/0 finger-safe connection to z-sv/ul-16 z-ek-50/ul contact your moeller representative for availability www.moellerusa.net www.moeller.ca
|
faz branch circuit breakers technical data shunt trip release faz-xaa-na faz-xaa-na12-110vac electrical can be mounted onto operational voltage range frequency possible standard auxiliary switch mechanical frame size device height device width mounting degree of protection built-in terminal protection terminals terminal capacity 1 and 2 wires faz-na faz-rt 12-110v ac 12-60v dc 50/60 hz z-nhk 45 mm 105 mm 17.5 mm 1mu quick fastening with 2 lock-in positions on din rail en 50022 ip40 finger and hand-touch safe according to bgv a3 Öve-en 6 box/lift awg 18-10 faz-xaa-na110-415vac faz-na faz-rt 110-415v ac 110-230v dc 50/60 hz z-nhk 45 mm 105 mm 17.5 mm 1mj quick fastening with 2 lock-in positions on din rail en 50022 ip40 finger and hand-touch safe according to bgv a3 Öve-en 6 box/lift awg 18-10 bus bar z-sv/ul-16 electrical rated voltage rated current short-circuit strength overvoltage category impulse voltage strength mechanical bus bar cross-section step distance climatic stability fla
|
faz branch circuit breakers notes www.moellerusa.net www.moeller.ca 1
|
faz supplementary protectors trip characteristic c designed for inductive loads response time of instantaneous trip 5 10 x in current rating ul recognized and csa certified as supplementary protectors for international and domestic use conform to iec en60898 type c characteristics suitable for applications where medium levels of inrush current are expected instantaneous trip is 5 to 10 x rating of device in applications include small transformers lighting pilot devices control circuits and coils medium magnetic trip point trip characteristic c designed for inductive loads 1 pole neutral 3 poles neutral rated current in a 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 type faz-c0,5/1n faz-c1/1n faz-c1,6/1n faz-c2/1n faz-c3/1n faz-c4/1n faz-c6/1n faz-c8/1n faz-c10/1n faz-c13/1n faz-c16/1n faz-c20/1n faz-c25/1n faz-c32/1n faz-c40/1n faz-c50/1n faz-c63/1n price type faz-c0,5/3n faz-c1/3n faz-c1,6/3n faz-c2/3n faz-c3/3n faz-c4/3n faz-c6/3n price faz-c16/3n faz-c20/3n faz-c25/3n f
|
faz supplementary protectors trip characteristic z designed for protection of electronic devices response time of instantaneous trip 2 3 x in current rating ul recognized and csa certified as supplementary protectors for international and domestic use conform to iec en60898 type z characteristics suitable for applications where semiconductors and other components that fail open are used instantaneous trip is 2 to 3 x continuous rating of device in the short thermal delay and low magnetic trip point are ideal for applications where devices and components have low surge and short circuit tolerances trip characteristic z designed for protection of electronic devices 1 pole 2 poles 3 poles 4 poles rated current in a 0.5 1 1.6 2 3 4 6 8 10 16 20 25 32 40 50 63 type faz-z0,5/1 faz-z1/1 faz-z1,6/1 faz-z2/1 faz-z3/1 faz-z4/1 faz-z6/1 faz-z8/1 faz-z10/1 faz-z16/1 faz-z20/1 faz-z25/1 faz-z32/1 faz-z40/1 faz-z50/1 faz-z63/1 price type price type price type price faz-z0,5/2 faz-z1/2 faz-z
|
faz supplementary protectors let-through characteristics let-through energy i2t 5 2 i dt 10 2 [a s 8 6 4 faz-b faz-c 63 a 50 a 40 a 32 a 25 a 20 a 16 a 13 a 10 a 5 2 i dt 10 2 8 [a s 6 4 faz-d 40 a 32 a 25 a 20 a 16 a 13 a 10 a 6a 2 1.5 104 8 6 2a 6a 4a 2 1.5 104 8 6 4 3a 4 faz b4hi 2 1.5 1a 2 1.5 103 8 6 4 103 8 6 4 3 0.5 1 1.5 2 3 4 5 6 7 8 9 10 0.5 a 15 0.5 1 1.5 2 3 4 5 6 7 8 9 10 15 i cc rms [ka i cc rms [ka i2dt [a2s 8 6 4 3 2 1.5 104 8 6 faz-k 63 a 50 a 40 a 32 a 25 a 20 a 16 a 13 a i2dt [a2s 8 6 4 3 2 1.5 104 8 faz-s 40 a 32 a 25 a 20 a 16 a 10 a 10 a 8a 6a 4a 3a 6a 4a 3a 2a 2a 4 3 2 1.5 103 1.6 a 6 4 3 2 1.5 1a 1a 103 5 4 3 0.5 1 1.5 2 3 4 5 6 7 8 9 10 0.5 a 5 0.5 1 1.5 2 3 4 5 6 7 8 9 10 i cc rms [ka i cc rms [ka www.moellerusa.net www.moeller.ca
|
faz supplementary protectors dimensions miniature circuit-breakers faz 9.4 17.7 35.4 53.1 70.8 80 5.5 44 60 auxiliary contacts faz-xhi11 faz-xam002 80 45 80 45 8.8 5.5 44 60 80 45 5.5 44 60 45 8.8 5.5 44 60 shunt releases faz-xaa undervoltage release s faz-xua 80 17.6 26.2 5.5 30.5 44 60 10 45 17.8 www.moellerusa.net www.moeller.ca 1
|
primary protection although permissible is not an ideal application since these protectors like fuses have a fixed current setting not ideally matched to the transformer s primary rated current a better choice for primary protection of control transformers consists of manual motor controllers additionally evaluated and marked as tap conductor protectors such as moeller s pkzm0 device since these have an adjustable thermal dial which can be set to the exact primary current rating of the transformer consult moeller for additional information on this application iec based miniature circuit breakers such as moeller s entire faz line are much more than just conventional supplementary protectors from an internal design point of view and can provide an ideal means to enhance the protective capabilities of any circuit · as mentioned they are in full compliance with the pertinent en/iec standards en/iec 60898 en/iec 60947-2 for miniature circuit breakers and can thus be applied outside of no
|
fazbranchcircuitbreakers csa 22.2 no 5 alphabetical listing by type type faz-d1,5/1-na faz-d1,5/1-rt faz-d1,5/2-na faz-d1,5/2-rt faz-d1,5/3-na faz-d1,5/3-rt faz-d1/1-na faz-d1/1-rt faz-d1/2-na faz-d1/2-rt faz-d1/3-na faz-d1/3-rt faz-d10/1-na faz-d10/1-rt faz-d10/2-na faz-d10/2-rt faz-d10/3-na faz-d10/3-rt faz-d13/1-na faz-d13/1-rt faz-d13/2-na faz-d13/2-rt faz-d13/3-na faz-d13/3-rt faz-d15/1-na faz-d15/1-rt faz-d15/2-na faz-d15/2-rt faz-d15/3-na faz-d15/3-rt faz-d16/1-na faz-d16/1-rt faz-d16/2-na faz-d16/2-rt faz-d16/3-na faz-d16/3-rt faz-d2/1-na faz-d2/1-rt faz-d2/2-na faz-d2/2-rt faz-d2/3-na faz-d2/3-rt faz-d20/1-na faz-d20/1-rt faz-d20/2-na faz-d20/2-rt faz-d20/3-na faz-d20/3-rt faz-d25/1-na faz-d25/1-rt faz-d25/2-na faz-d25/2-rt faz-d25/3-na faz-d25/3-rt faz-d3/1-na faz-d3/1-rt faz-d3/2-na faz-d3/2-rt faz-d3/3-na faz-d3/3-rt faz-d30/1-na faz-d30/1-rt faz-d30/2-na page 7 5 7 5 7 5 7 5 7 5 7 5 7 5 7 5 7 5 7 5 7 5 7 5 7 5 7 5 7 5 7 5 7 5 7 5 7 5 7 5 7 5 7 5 7 5 7 5 7 5 7 5 7 5 7 5 7 5
|
www.moeller.ca moeller canadian head office 7275 rapistan court mississauga ontario canada l5n 5z4 tel 905.542.2323 fax 905.542.2321 moeller corporate headquarters 4140 world houston parkway 100 houston texas usa 77032 tel 713.933.0999 fax 832.613.6255 © 2006 by moeller inc technical and other changes reserved publication faz-cat-cdn-0706 article no 695008
|