Catalog: Miniature Circuit Breakers
Company/Brand: Moeller Electric USA
|
| | pages 33 38 40 41 miniature circuit breakers think future switch to green ...
|
| | faz branch circuit breakers general information selection tables ... applications applying branch circuit breakers and supplementary protectors in north ...
|
| | series faz branch circuit breakers branch circuit protection up to 10ka ... its faz line of miniature circuit breakers to include devices that are listed and ... certified as molded case circuit breakers per ul 489 and csa 22.2 no 5-02 these ... new branch circuit breakers called faz-na are ideal for the ... applying moeller s faz branch circuit breakers are available in one two and three pole ... ratings ranging from 0.5a to 40a all breakers are available in both c and d tripping ... installation options faz branch circuit breakers are available in two terminal ... of the semi-conductor industry all breakers mount on standard 35mm din-rail bus ... panel assemblies power to the circuit breakers can also be fed from the line or load ... green for off red for on all faz breakers incorporate a tripfree mechanism this ...
|
| | moeller faz-nart branch circuit breakers are available with c and d tripping ... by nec or cec for branch circuit breakers moeller s faz-nart devices are current ... c and d devices faz-na branch circuit breakers tr ipping time t [sec 10 3 4 type c 5 i ... kept apart for mechanical reliability breakers install on standard din-rail bimetal ...
|
| | faz branch circuit breakers trip characteristic c ul approved ... csa c22.2 no 5-02 as branch circuit breakers interrupting capacity 10ka ul/csa 15ka ...
|
| | faz branch circuit breakers trip characteristic d ul approved ... csa c22.2 no 5-02 as branch circuit breakers interrupting capacity 10ka ul/csa 15ka ...
|
| | faz branch circuit breakers ring tongue trip characteristic c ... csa c22.2 no 5-02 as branch circuit breakers connections for ring-tongue terminals ... /3-rt faz-c6/3-rt faz-c7/3-rt price all breakers on this page are equipped with ...
|
| | faz branch circuit breakers ring tongue trip characteristic d ... csa c22.2 no 5-02 as branch circuit breakers connections for ring-tongue terminals ... /3-rt faz-d6/3-rt faz-d7/3-rt price all breakers on this page are equipped with ...
|
| | faz branch circuit breakers accessories for all faz na and faz rt ... miniature circuit breakers accessories description selectable 2- ...
|
| | faz branch circuit breakers accessories bus bar system bus bar ...
|
| | faz branch circuit breakers let-through characteristics let-through ...
|
| | faz branch circuit breakers technical data tripping characteristics ...
|
| | faz branch circuit breakers technical data faz-na faz-rt miniature ... circuit breakers faz-na faz-rt electrical design ...
|
| | faz branch circuit breakers technical data selectable aux contact ...
|
| | faz branch circuit breakers technical data shunt trip release faz- ...
|
| | faz branch circuit breakers dimensions faz-na faz-rt 1p 2p 3p 5.5 ...
|
| | faz branch circuit breakers dimensions z-sv/ul-16 p te/6 5x17.6 =88 ...
|
| | faz branch circuit breakers dimensions incoming supply terminals z- ...
|
| | faz branch circuit breakers dimensions lockout attachment lo ck of ...
|
| | faz branch circuit breakers notes www.moellerusa.net www.moeller.ca ...
|
| | moeller s faz line of miniature circuit breakers includes a broad range of devices ... as supplementary protectors these breakers comply with ul 1077 and csa 22.2 no 235 ... product range worldwide approvals all breakers mount on a standard 35mm din-rail each ... panel assemblies power to the circuit breakers can also be fed from the line or load ... for on and isolation function all faz breakers also incorporate a trip-free ...
|
| | and 480y/277v ac for multi-pole to 40a breakers install on standard din-rail available ...
|
| | code part 1 c22.1 supplementary breakers cannot be used as a substitute for the ... is not required see faz branch circuit breakers in this catalog see trip curve chart on ...
|
| | code part 1 c22.1 supplementary breakers cannot be used as a substitute for the ... is not required see faz branch circuit breakers in this catalog 2 3 4 5 6 7 8 9 10 15 ...
|
| | code part 1 c22.1 supplementary breakers cannot be used as a substitute for the ... is not required see faz branch circuit breakers in this catalog see trip curve chart on ...
|
| | code part 1 c22.1 supplementary breakers cannot be used as a substitute for the ... is not required see faz branch circuit breakers in this catalog 2 3 4 5 6 7 8 9 10 15 ...
|
| | code part 1 c22.1 supplementary breakers cannot be used as a substitute for the ... is not required see faz branch circuit breakers in this catalog see trip curve chart on ...
|
| | code part 1 c22.1 supplementary breakers cannot be used as a substitute for the ... is not required see faz branch circuit breakers in this catalog 2 3 4 5 6 7 8 9 10 15 ...
|
| | /4 see green pages special order these breakers are available by special order only ... code part 1 c22.1 supplementary breakers cannot be used as a substitute for the ... is not required see faz branch circuit breakers in this catalog see trip curve chart on ...
|
| | .30 uitn for t 1 h special order these breakers are available by special order only ... code part 1 c22.1 supplementary breakers cannot be used as a substitute for the ... is not required see faz branch circuit breakers in this catalog 1 2 3 4 5 6 7 8 9 10 15 ...
|
| | /4 see green pages special order these breakers are available by special order only ... code part 1 c22.1 supplementary breakers cannot be used as a substitute for the ... is not required see faz branch circuit breakers in this catalog 0.2 0.1 0.05 0.02 0.01 ...
|
| | /2 see green pages special order these breakers are available by special order only ... code part 1 c22.1 supplementary breakers cannot be used as a substitute for the ... is not required see faz branch circuit breakers in this catalog 0.02 0.01 0.005 0.002 0 ...
|
| | faz supplementary protectors accessories auxiliary contacts and voltage trips module circuit diagram description standard auxiliary contact 1 no 1 nc installs on left side of faz or shunt trip max one per faz 1077 device switches when faz is tripped electrically or manually rated operational voltage type price 230v ac faz-xhi11 selectable 2-pole auxiliary contact or auxiliary/trip-indicating contacts small selector screw changes mode two form c changeover contacts installs on left side of faz or shunt trip aux contacts switch when faz is tripped electrically or manually trip ...
|
| | faz supplementary protectors accessories bus bar system description for connecting faz supplementary protectors without auxiliary contacts may be fed from line or load side number of poles per device rated number of operational terminals current a 2 type evg-16/1phas/2modul evg-16/1phas/6modul evg-16/1phas/12modul evg-16/2phas/4modul evg-16/2phas/6modul price 1 6 12 4 2 faz faz faz 6 80 12 6 evg-16/2phas/12modul evg-16/3phas/6modul evg-16/3phas/12modul evg-16/4phas/8modul evg-16/4phas/12modul evg-16/1phas/2modul/hi evg-16/1phas/6modul/hi evg-16/1phas/9modul/hi evg-16/2phas/4modul/hi 80 evg-16/2phas/6modul/hi ...
|
| | faz supplementary protectors accessories incoming supply terminals accessories description installation type price fork connector accommodates conductors up to 25 mm2 awg 4 finger-safe connection faz-xk25 faz-xk25 bus connector for conductors up to 35 mm2 awg 2 finger-safe connection to faz-xis faz faz faz-xk35 see green pages faz-xk25 faz-xk35 protective accessories accessories description type price bus bar terminal cover for covering unused terminals faz-xbs bracket for securing the covers two required per group of supplementary protectors reg-bb see green pages padlock hasp prevents ...
|
| | faz supplementary protectors let-through characteristics let-through energy i2t 5 2 i dt 10 2 [a s 8 6 4 faz-b faz-c 63 a 50 a 40 a 32 a 25 a 20 a 16 a 13 a 10 a 5 2 i dt 10 2 8 [a s 6 4 faz-d 40 a 32 a 25 a 20 a 16 a 13 a 10 a 6a 2 1.5 104 8 6 2a 6a 4a 2 1.5 104 8 6 4 3a 4 faz b4hi 2 1.5 1a 2 1.5 103 8 6 4 103 8 6 4 3 0.5 1 1.5 2 3 4 5 6 7 8 9 10 0.5 a 15 0.5 1 1.5 2 3 4 5 6 7 8 9 10 15 i cc rms [ka i cc rms [ka i2dt [a2s 8 6 4 3 2 1.5 104 8 6 faz-k 63 a 50 a 40 a 32 a 25 a 20 a 16 a 13 a i2dt [a2s 8 6 4 3 2 1.5 104 8 faz-s 40 a 32 a 25 a 20 a 16 a 10 a 10 a 8a 6a 4a 3a 6a 4a 3a 2a 2a 4 3 2 1.5 ...
|
| | faz supplementary protectors let-through characteristics let-through energy i2t i2dt [a2s 8 6 4 3 2 1.5 6a faz-z 63 a 50 a 40 a 32 a 25 a 20 a 16 a 10 a 8a 104 8 6 4 3 2a 4a 3a 2 1.5 103 5 4 3 0.5 1 1.5 2 3 4 5 6 1.6 a 1a 0.5 a 7 8 9 10 i cc rms [ka let-through current id www.moeller.ca www.moellerusa.net
|
| | faz supplementary protectors let-through characteristics let-through current id www.moellerusa.net www.moeller.ca
|
| | faz supplementary protectors technical data b curve electrical approvals standards short circuit trip response supplementary protectors ul csa current range maximum voltage ratings ul csa 1 pole 1 pole neutral 2 3 4 pole 3 pole neutral thermal tripping characteristics single pole multi-pole short circuit ratings at max voltage 1 pole 1 pole neutral 2 3 4 pole 3 pole neutral 2 poles in series miniature circuit breaker iec current range maximum voltage ratings iec 1 pole 1 pole neutral 2 3 4 pole 3 pole neutral thermal tripping characteristics single pole multi-pole interrupt ratings ...
|
| | capacity of adjoining miniature circuit-breakers 45 50 55 60 in [a 0.16 0.25 0.5 0.75 1 ...
|
| | faz supplementary protectors technical data faz-xhi11 auxiliary faz-xam002 aux/trip indication electrical contact function xhi11 xam002 rated operational voltage 1m 1b 2 c/o 250 faz-xaa-c shunt trip faz-xua undervoltage trip 115 230 400 un [v ac voltage range [v ac [v dc 50/60 2/2 0.5 0.5 a600 q600 4 3 250 v ac 2 250 v ac 0.5 110 v dc 250 5 2.5 1 4 45 80 8.8 on mcb ip40 protection against electric shock to iec 536 lift terminals [mm2 [mm2 [nm 0.5 2.5 0.5 2.5 0.8 1.0 closing threshhold tripping threshhold rated frequency general use ul csa ac dc pilot duty conventional free ...
|
| | protectors dimensions miniature circuit-breakers faz 9.4 17.7 35.4 53.1 70.8 80 5.5 44 ...
|
| | faz branch circuit breakers notes www.moeller.ca www.moellerusa.net ...
|
| | applying branch circuit breakers and supplementary protectors in north ...
|
| | applying branch circuit breakers and supplementary protectors in north ... offers two types of miniature circuit breakers for use in north america the first ... iec standards for miniature circuit breakers en/iec 60 898 and en/iec 60 947-2 both ... of iec-style miniature circuit breakers because moeller s faz miniature circuit ... breakers are iec-style devices it is important ... · iec-style miniature circuit breakers are thermal-magnetic inverse time ... operated and like all modern circuit breakers feature a trip-free mechanism this ... for low voltage 1000v circuit breakers in europe and the rest of the iec world ... america most european miniature circuit breakers are only ul recognized and csa ... requirements for molded case circuit breakers and are marked accordingly this makes ...
|
| | and certified molded case circuit breakers and fuses that explains in part their ...
|
| | application iec based miniature circuit breakers such as moeller s entire faz line are ... en/iec 60947-2 for miniature circuit breakers and can thus be applied outside of ... downstream loads and circuits circuit breakers that are classified as current ... and miniature molded case circuit breakers are current limiting protective devices ... characteristics miniature circuit breakers are thermal-magnetic inverse time ...
|
| | curve for faz miniature circuit breakers can be seen here typical inverse time ... design of moeller miniature circuit breakers 7200 3600 t [s 1.13 1.45 speci ed non- ... 001 0.0005 1 faz-nart miniature circuit breakers as previously mentioned moeller has ... its faz line of miniature circuit breakers to include a version which is listed ... iec standard for molded case circuit breakers iec 60947-2 and can therefore be ... the code that definition sets circuit breakers apart from any other protective device ... that regular testing on circuit breakers be conducted by ul and csa at the ...
|
| | rating of 10ka current limiting circuit breakers substantially reduce the amount of ... current hacr and swd faz-nart circuit breakers are also marked hacr for use in ... protectors and molded case circuit breakers it is important to keep in mind that ... 1077 and faz-nart molded case circuit breakers ul 489 must not be interpreted in the ... devices conversely molded case circuit breakers are primary overcurrent protective ... 10ka 5ka 10ka faz na rt branch circuit breakers ul 489 single pole 2 3 pole trip ... devices such as molded case circuit breakers as well as self-protected type e ...
|
| | price list miniature circuit breakers use only with publication faz-cat-cdn ...
|
| | fazbranchcircuitbreakers csa 22.2 no 5 alphabetical listing by type type faz-c0,5/1-na faz-c0,5/1-rt faz-c0,5/2-na faz-c0,5/2-rt faz-c0,5/3-na faz-c0,5/3-rt faz-c1,5/1-na faz-c1,5/1-rt faz-c1,5/2-na faz-c1,5/2-rt faz-c1,5/3-na faz-c1,5/3-rt faz-c1/1-na faz-c1/1-rt faz-c1/2-na faz-c1/2-rt faz-c1/3-na faz-c1/3-rt faz-c10/1-na faz-c10/1-rt faz-c10/2-na faz-c10/2-rt faz-c10/3-na faz-c10/3-rt faz-c13/1-na faz-c13/1-rt faz-c13/2-na faz-c13/2-rt faz-c13/3-na faz-c13/3-rt faz-c15/1-na faz-c15/1-rt faz-c15/2-na faz-c15/2-rt faz-c15/3-na faz-c15/3-rt faz-c16/1-na faz-c16/1-rt faz-c16/2-na faz-c16/2-rt faz-c16/3-na ...
|
| | fazbranchcircuitbreakers csa 22.2 no 5 alphabetical listing by type type faz-d1,5/1-na faz-d1,5/1-rt faz-d1,5/2-na faz-d1,5/2-rt faz-d1,5/3-na faz-d1,5/3-rt faz-d1/1-na faz-d1/1-rt faz-d1/2-na faz-d1/2-rt faz-d1/3-na faz-d1/3-rt faz-d10/1-na faz-d10/1-rt faz-d10/2-na faz-d10/2-rt faz-d10/3-na faz-d10/3-rt faz-d13/1-na faz-d13/1-rt faz-d13/2-na faz-d13/2-rt faz-d13/3-na faz-d13/3-rt faz-d15/1-na faz-d15/1-rt faz-d15/2-na faz-d15/2-rt faz-d15/3-na faz-d15/3-rt faz-d16/1-na faz-d16/1-rt faz-d16/2-na faz-d16/2-rt faz-d16/3-na faz-d16/3-rt faz-d2/1-na faz-d2/1-rt faz-d2/2-na faz-d2/2-rt faz-d2/3-na ...
|
| | fazsupplementaryprotector s csa 22.2 no 235 alphabetical listing by type type evg-16/1phas/12modul evg-16/1phas/2modul evg-16/1phas/2modul/hi evg-16/1phas/6modul evg-16/1phas/6modul/hi evg-16/1phas/9modul/hi evg-16/2phas/10modul/hi evg-16/2phas/12modul evg-16/2phas/4modul evg-16/2phas/4modul/hi evg-16/2phas/6modul evg-16/2phas/6modul/hi evg-16/3phas/12modul evg-16/3phas/12modul/hi evg-16/3phas/6modul evg-16/3phas/6modul/hi evg-16/4phas/12modul evg-16/4phas/8modul faz/fip-xsv faz-b10/1 faz-b10/1n faz-b10/2 faz-b10/3 faz-b10/3n faz-b10/4 faz-b12/1 faz-b12/1n faz-b12/2 faz-b12/3 faz-b12/3n faz-b12/4 ...
|
| | fazsupplementaryprotector s csa 22.2 no 235 alphabetical listing by type type faz-c13/4 faz-c16/1 faz-c16/1n faz-c16/2 faz-c16/3 faz-c16/3n faz-c16/4 faz-c2/1 faz-c2/1n faz-c2/2 faz-c2/3 faz-c2/3n faz-c2/4 faz-c20/1 faz-c20/1n faz-c20/2 faz-c20/3 faz-c20/3n faz-c20/4 faz-c25/1 faz-c25/1n faz-c25/2 faz-c25/3 faz-c25/3n faz-c25/4 faz-c3/1 faz-c3/1n faz-c3/2 faz-c3/3 faz-c3/3n faz-c3/4 faz-c32/1 faz-c32/1n faz-c32/2 faz-c32/3 faz-c32/3n faz-c32/4 faz-c4/1 faz-c4/1n faz-c4/2 faz-c4/3 faz-c4/3n faz-c4/4 faz-c40/1 faz-c40/1n faz-c40/2 faz-c40/3 faz-c40/3n faz-c40/4 faz-c50/1 faz-c50/1n faz-c50/2 faz-c50/3 ...
|
| | fazsupplementaryprotector s csa 22.2 no 235 alphabetical listing by type type faz-k1,6/3n faz-k1,6/4 faz-k1/1 faz-k1/2 faz-k1/3 faz-k1/3n faz-k1/4 faz-k10/1 faz-k10/2 faz-k10/3 faz-k10/3n faz-k10/4 faz-k13/1 faz-k13/2 faz-k13/3 faz-k13/3n faz-k13/4 faz-k16/1 faz-k16/2 faz-k16/3 faz-k16/3n faz-k16/4 faz-k2/1 faz-k2/2 faz-k2/3 faz-k2/3n faz-k2/4 faz-k20/1 faz-k20/2 faz-k20/3 faz-k20/3n faz-k20/4 faz-k25/1 faz-k25/2 faz-k25/3 faz-k25/3n faz-k25/4 faz-k3/1 faz-k3/2 faz-k3/3 faz-k3/3n faz-k3/4 faz-k32/1 faz-k32/2 faz-k32/3 faz-k32/3n faz-k32/4 faz-k4/1 faz-k4/2 faz-k4/3 faz-k4/3n faz-k4/4 faz-k40/1 ...
|
| | fazsupplementaryprotector s csa 22.2 no 235 alphabetical listing by type type faz-z16/2 faz-z16/3 faz-z16/4 faz-z2/1 faz-z2/2 faz-z2/3 faz-z2/4 faz-z20/1 faz-z20/2 faz-z20/3 faz-z20/4 faz-z25/1 faz-z25/2 faz-z25/3 faz-z25/4 faz-z3/1 faz-z3/2 faz-z3/3 faz-z3/4 faz-z32/1 faz-z32/2 faz-z32/3 faz-z32/4 faz-z4/1 faz-z4/2 faz-z4/3 faz-z4/4 faz-z40/1 faz-z40/2 faz-z40/3 faz-z40/4 faz-z50/1 faz-z50/2 faz-z50/3 faz-z50/4 faz-z6/1 faz-z6/2 faz-z6/3 faz-z6/4 faz-z63/1 faz-z63/2 faz-z63/3 faz-z63/4 faz-z8/1 faz-z8/2 faz-z8/3 faz-z8/4 reg-bb page 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 ...
|
| | www.moeller.ca moeller canadian head office 7275 rapistan court mississauga ontario canada l5n 5z4 tel 905.542.2323 fax 905.542.2321 moeller corporate headquarters 4140 world houston parkway 100 houston texas usa 77032 tel 713.933.0999 fax 832.613.6255 © 2006 by moeller inc technical and other changes reserved publication faz-cat-cdn-0706 article no 695008
|