20 results for c 5 found in 0.008 seconds

 

Catalog: Miniature Circuit Breakers
Company/Brand: Moeller Electric USA


 

faz branch circuit breakers general information selection ... tables trip characteristic c box terminals trip characteristic d ... box terminals trip characteristic c ring tongue terminals trip ... characteristic d ring tongue terminals accessories ... 2 4 5 6 7 8 technical data 10 dimensions ... information 20 selection tables trip characteristic b 22 trip characteristic c 24 trip ... characteristic d 26 trip characteristic k 28 trip characteristic z 30 trip ... characteristic s 31 accessories 32 technical data ... 41 mcb applications applying branch circuit breakers and supplementary protectors ... in north america 43 pricing can be found on the green pages in this ...


 

series faz branch circuit breakers branch circuit protection up ... just expanded its faz line of miniature circuit breakers to include devices that are ... listed and certified as molded case circuit breakers per ul 489 and csa 22.2 no 5- ... 02 these new branch circuit breakers called faz-na are ideal for the protection of ... power supplies control power transformers hvac refrigeration ... faz applying moeller s faz branch circuit breakers are available in one two and ... three pole configurations with 20 different current ratings ... ranging from 0.5a to 40a all breakers are available in ... both c and d tripping curves offering protection from 5 to 10 and 10 ... to 20 x the continuous rating of the device in two and three ...


 

tripping characteristics moeller faz-nart branch circuit ... breakers are available with c and d tripping characteristics c- ... curve devices are suitable for applications ... where medium levels of inrush current are expected applications include small ... transformers lighting pilot devices control circuits and coils c-curve devices ... magnetic trip point devices with a d curve are suitable for applications where ... high levels of inrush current are expected the high magnetic trip ... even though not required by nec or cec for branch circuit breakers moeller s ... faz-nart devices are current limiting which means they interrupt ... fault currents within one half cycle of the fault current limiting devices ...


 

faz branch circuit breakers trip characteristic c ul approved ul489 and csa ... certified csa c22.2 no 5-02 as branch circuit breakers interrupting capacity 10ka ul/ ... csa 15ka iec 60947 trip characteristic c response time of instantaneous trip 5 ... ­ 10 x in current rating current limiting device type c characteristics ... where medium levels of inrush current are expected instantaneous trip is 5 to ... transformers lighting pilot devices control circuits and coils medium magnetic trip ... point trip characteristic c ­ designed for inductive loads 1 pole 2 ... poles 3 poles rated current in a 0.5 1 1.5 2 3 4 5 6 7 8 10 13 15 16 20 25 ...


 

faz branch circuit breakers ring tongue trip ... characteristic c ul approved ul489 and csa certified ... csa c22.2 no 5-02 as branch circuit breakers connections for ring-tongue ... terminals trip characteristic c response time of instantaneous trip 5 ... ­ 10 x in current rating interrupting capacity 10ka ul/csa 15ka iec 60947 type c ... characteristics suitable for applications where medium ... levels of inrush current are expected instantaneous trip is 5 to ... transformers lighting pilot devices control circuits and coils medium magnetic trip ... point trip characteristic c ­ designed for inductive loads 1 pole 2 ... poles 3 poles rated current in a 0.5 1 1.5 2 3 4 5 6 7 8 10 13 15 16 20 25 ...


 

faz branch circuit breakers let-through characteristics let-through energy characteristic c 0.5 ... -20a 277v 80000 70000 60000 50000 40000 30000 20000 15000 0 c2 c1 c1 6 ... characteristic c 25-40a 240v 80000 70000 60000 50000 ... 20000 15000 10000 9000 8000 7000 6000 5000 4000 3000 2000 1500 1000 900 800 700 ... 600 500 400 c 0.5 c40 c35 c32 c30 c25 5 c13 c10 c8 7 c6 c c5 c4 c3 let-through ... energy i t [a sec 5000 4000 3000 2000 1500 1000 900 800 700 ... 600 500 400 300 c2 c 1,5 c1 let-through energy i t [a sec 10000 ... 9000 8000 7000 6000 300 500 1000 1500 2000 1000 1500 2000 7000 8000 ...


 

faz branch circuit breakers technical data tripping ... characteristics 7200 3600 1200 600 2 influence of ... ambient temperature t on load carrying capacity tripping characteristic acc to ul 489 ... csa 22.2 no 235 1 2 1 1.40 conventional non-tripping current int 1.0 i n t=40 ° ... c conventional tripping current i t 1.35 i n t 1 h t=25 °c 2.0 i n ... t 12 120 s t=25 °c 300 120 60 30 1.30 3 3 load factor kt ... 1.20 tr ipping time t [sec 10 3 4 type c 5 i n t 0.1 s 10 i n t 0.1 s type d ... 10 i n t 0.1 s 20 i n t 0.1 s 5 2 1 0.5 0.2 0.1 0.05 0.02 0.01 0.005 0.002 0. ... 001 6 1.10 1.00 4 4 5 c 5 d 0.90 -20 -10 0 10 20 30 40 50 ambient ... temperature t [°c maximum load il at ambient temperature ...


 

faz branch circuit breakers technical data faz-na faz-rt ... miniature circuit breakers faz-na faz-rt electrical ... design according to current test marks as printed onto the device ... rated voltage ul/csa 0.5 ­ 20a ul/csa 25 ­ 40a iec rated frequency rated ... breaking capacity ul/csa iec characteristic endurance line voltage connection ... upper and lower terminals terminal capacity terminal fastening torque mounting ... calibration temperature ul 489 csa c22.2 no 5 iec 60947-2 ul 489 csa c22.2 no 5 ... -2 277/480y vac 240 vac 240/415 vac 50/60 hz 10 ka 15 ka c d 20,000 operating ... cycles operational suitable for reverse feed ...


 

six tripping curves to choose moeller faz supplementary protectors ... available with six different tripping characteristics including type b c d k s and z ... definitions for each trip curve are contained on the ordering pages and can be used ... to determine the optimal characteristic for your application for example low ... level short-circuit faults in control wiring such as plcs are best protected ... by devices with type b trip characteristics 3 to 5 x continuous rating of the ... in even though not required by nec or cec for supplementary protectors moeller s ... faz devices are current limiting which means they interrupt ... fault currents within one half cycle current limiting devices offer superior ...


 

faz supplementary protectors trip characteristic b designed for resistive or ... response time of instantaneous trip 3 ­ 5 x in current rating ul recognized and ... csa certified as supplementary protectors for ... international and domestic use conform to iec en60898 type b characteristics ... protection against low level short circuit faults in control wiring is desired ... instantaneous trip is 3 to 5 x continuous rating of device in applications ... motors low magnetic trip point trip characteristic b ­ designed for resistive or slightly ... 1 pole neutral 3 poles neutral rated current in a 6 8 10 12 13 15 16 20 25 32 40 50 ... [s 1.13 1.45 1200 600 300 120 60 30 10 5 2 1 0.5 0.2 0.1 0.05 0.02 0.01 0.005 0. ...


 

faz supplementary protectors trip characteristic c designed for inductive loads ... response time of instantaneous trip 5 ­10 x in current rating ul recognized ... and csa certified as supplementary protectors for ... international and domestic use conform to iec en60898 type c characteristics ... where medium levels of inrush current are expected instantaneous trip is 5 to ... transformers lighting pilot devices control circuits and coils medium magnetic trip ... point trip characteristic c ­ designed for inductive loads 1 pole 2 ... poles 3 poles 4 poles rated current in a 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 ... 32 40 50 63 faz-c1/1 type faz-c0,5/1 faz-c1,6/1 faz-c2/1 faz-c3/1 faz-c4/1 ...


 

faz supplementary protectors trip characteristic c designed for inductive loads ... response time of instantaneous trip 5 ­10 x in current rating ul recognized ... and csa certified as supplementary protectors for ... international and domestic use conform to iec en60898 type c characteristics ... where medium levels of inrush current are expected instantaneous trip is 5 to ... transformers lighting pilot devices control circuits and coils medium magnetic trip ... point trip characteristic c ­ designed for inductive loads 1 pole ... neutral 3 poles neutral rated current in a 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 ... 32 40 50 63 type faz-c0,5/1n faz-c1/1n faz-c1,6/1n faz-c2/1n faz-c3/1n faz- ...


 

faz supplementary protectors trip characteristic d designed for highly inductive ... time of instantaneous trip 10 ­20 x in current rating ul recognized and csa certified ... for international and domestic use conform to iec en60898 type d characteristics ... where high levels of inrush current are expected instantaneous trip is 10 ... transformers and power supplies trip characteristic d ­ designed for highly inductive loads ... 3 poles neutral rated current in a 6 8 10 13 16 20 25 32 40 type faz- ... [s 1.13 1.45 1200 600 300 120 60 30 10 5 2 1 0.5 0.2 0.1 0.05 0.02 0.01 0.005 0. ... 0.001 0.0005 1 speci ed non-tripping current int 1.13 x in for t 1 h speci ed ... tripping current it 1.45 x in for t 1 h 2.55 x in t ...


 

supplementary protectors let-through characteristics let-through energy i2t 5 2 i dt 10 2 [a ... s 8 6 4 faz-b faz-c 63 a 50 a 40 a 32 a 25 a 20 a 16 a 13 a 10 a 5 ... a 32 a 25 a 20 a 16 a 13 a 10 a 6a 2 1.5 104 8 6 2a 6a 4a 2 1.5 104 8 6 4 3a 4 ... faz b4hi 2 1.5 1a 2 1.5 103 8 6 4 103 8 6 4 3 0.5 1 1.5 2 3 4 5 ... 6 7 8 9 10 0.5 a 15 0.5 1 1.5 2 3 4 5 6 7 8 9 10 15 i cc rms [ka i cc rms [ka ... i2dt [a2s 8 6 4 3 2 1.5 104 8 6 faz-k 63 a 50 a 40 a 32 a 25 a ... 20 a 16 a 13 a i2dt [a2s 8 6 4 3 2 1.5 104 8 faz-s 40 a 32 a 25 a 20 a 16 a 10 ... 10 a 8a 6a 4a 3a 6a 4a 3a 2a 2a 4 3 2 1.5 103 1.6 a 6 4 3 2 1.5 1a 1a 103 5 4 3 0 ... .5 1 1.5 2 3 4 5 6 7 8 9 10 0.5 a 5 0.5 1 1.5 2 3 4 5 6 7 8 9 10 i cc rms [ka i ...


 

protectors technical data b curve electrical approvals standards short ... circuit trip response supplementary protectors ... ul csa current range maximum voltage ratings ­ ul csa ... pole 3 pole neutral thermal tripping characteristics single pole multi-pole short circuit ... neutral 2 poles in series miniature circuit breaker iec current range maximum ... pole 3 pole neutral thermal tripping characteristics single pole multi-pole interrupt ... at max voltage operational switching capacity max back-up fuse rated impulse ... ui environmental general selectivity class lifespan shock iec 68-2-22 operating ... terminals top and bottom supply connection terminal capacity torque thickness of ...


 

on the thermal tripping behavior corrected values of the rated current dependent ... on the ambient temperature load carrying capacity of adjoining miniature circuit ... -breakers 45 50 55 60 in [a 0.16 0.25 0.5 0.75 1 1.5 1.6 2 2.5 3 3.5 4 5 6 8 10 ... 12 13 15 16 20 25 32 40 50 63 -25 -20 -10 0 ambient temperature t ... [°c 10 20 30 35 40 0.20 0.19 0.19 0.18 0.17 ... 25 0.24 0.24 0.23 0.23 0.22 0.61 0.60 0.58 0.56 0.54 0.52 0.50 0.49 0.48 0.47 0.46 ... 24 30 38 48 60 76 1.2 1.7 1.9 2.3 2.9 3.5 4.1 4.7 5.8 7.0 9.3 12 14 15 17 19 23 ... 29 37 47 58 73 1.1 1.7 1.8 2.2 2.8 3.4 3.9 4.5 5.6 ... 6.7 9.0 11 13 15 17 18 22 28 36 45 56 71 1.1 1.6 1.7 2.2 2.7 3.3 3.8 4.3 5.4 ...


 

-xam002 aux/trip indication electrical contact function xhi11 xam002 rated operational ... voltage 1m 1b 2 c/o 250 faz-xaa-c shunt trip ­ ­ faz-xua undervoltage ... [v ac voltage range [v ac [v dc ­ ­ ­ 50/60 2/2 0.5 0.5 a600 q600 4 3 250 v ac ... 2 250 v ac 0.5 110 v dc 250 5 2.5 1 4 45 80 8.8 on mcb ip40 protection ... against electric shock to iec 536 lift terminals [mm2 [mm2 [nm 0.5 ­ 2.5 ... 0.5 ­ 2.5 0.8 ­ 1.0 closing threshhold tripping threshhold rated ... frequency general use ul csa ac dc pilot duty conventional free air ... thermal current rated operational current ac-13 ac-15 dc-13 rated insulation ...


 

response times apply to each of the characteristic letters referenced in moeller faz part ... · b instantaneous response between 3 5 x in in fixed current rating of each ... suited for resistive loads such as conductors or heaters · c instantaneous response ... between 5 10 x in ­ ideally suited for inductive ... highly inductive loads especially in control circuits with coils and light filaments ... of overcurrents a typical tripping characteristic curve for faz miniature circuit ... breakers can be seen here typical inverse time ... tripping characteristic of a miniature circuit breaker inverse time refers to the ... device s tripping characteristic as the curve shows the higher the current the lower ...


 

the advantages of a current limiting device as already mentioned ... all moeller faz devices are current limiting by design in the case of the ... ul 489 devices they are also classified by ul/csa in that manner and are marked ... on the label a circuit breaker that is marked as a current ... element and when operating within its current limiting range limits the let-through ... i2t to less than the energy of a ½ cycle wave of the available symmetrical ... current the label on faz-nart devices lists the ... i2t 45 ka2 s and peak letthrough current 6.2ka at the maximum interrupting ... rating of 10ka current limiting circuit breakers substantially reduce the ... of damage sustained by downstream components in the event of a high short circuit ...


 

fazsupplementaryprotector s csa 22.2 no 235 alphabetical listing by ... 28 28 28 29 28 28 list price 105 115 22 55 90 105 115 22 55 90 105 115 22 55 90 ... 105 115 22 55 90 105 115 22 55 90 105 115 22 55 90 105 115 22 55 90 ... 105 115 22 55 90 105 115 22 55 90 105 115 22 55 90 105 115 22 55 90 ... /1 faz-s40/2 faz-s6/1 faz-s6/2 faz-xaa-c-110-415vac faz-xaa-c-12-110vac faz-xam002 faz-xbs ... faz-xua230vac faz-xua400vac faz-z0,5/1 faz-z0,5/2 faz-z0,5/3 faz-z0,5/4 faz- ... 30 30 30 30 30 30 30 30 30 list price 55 90 105 115 40 90 155 175 190 22 55 90 ...


 
  Similar searches   c 5 tail lights (81)
c 5 park light (155)
mazda 5 roof rack (19)
mazda 5 roof racks (19)
mazda 5 accessories (97)
16 5 10 5 on 4 5 wheels (901)
c clip eliminator (129)
flying c (443)
ford v8 5 3l 302 (49)
perfect performance products l l c (31)
ralph c lee (23)
stanley 5 drawer tool chest (6)
caribe deck 5 (7)
om 5 (424)
transmission t 5 (872)
mazda 5 rear cargo cover (33)
force 5 air winch (27)
mazda 5 (483)
2008 mazda 5 (35)
67 5 (76)
for loop in c (312)
for loop in c language (34)
r 1200 c (284)
5 speed jaguar xk (71)
c cm (943)
mazda 5 door (90)
mazda 5 rear door (68)
vx 5 (81)
16 oz 5 minute epoxy (19)
cleco 5 (189)
c 760 (284)
system 5 helmet (53)
t 5 transmission (872)
18 x 80 front 18 x 85 rear 5 spoke cast ... (6)
5 speed tran for 97 jetta (21)
trans jetta 5 speed (37)
ford focus c max 2006 (14)
ford c max (100)
ford c max 06 (21)
mazda 5 speed (91)
6 bolt to 5 bolt adapter (347)
corsa c (33)
c 1010 (273)
c 3 corvette door panel clips (19)
dvd navigation c max 2007 (10)
2006 c max (180)
2006 focus c max (26)
5 series rims (135)
mazda mx 5 1994 (7)
5 speed clutch kit 95 passat vr6 (12)
c 372 (288)
mazda 5 rear wipers (15)
ford 5 speed shifter (64)
5 speed international (870)
vauxhall corsa c (9)
t 5 bell housing (78)



Home | Latest catalogs | Contact

© 2006-2008 by who-sells-it.com