Catalog: Miniature Circuit Breakers
Company/Brand: Moeller Electric USA
|
| | characteristics c-curve devices are suitable for applications where medium levels of ... are expected applications include small transformers lighting pilot devices ... trip point devices with a d curve are suitable for applications where high levels of ... tripping in high inductive applications such as motors transformers and power ... supplies even though not required by nec or cec ... for branch circuit breakers moeller s faz-nart devices are current limiting ... fault current limiting devices offer superior protection by reducing peak letthrough ... i n t 1 h t=25 °c 2.0 i n t 12 120 s t=25 °c 300 120 60 30 3 3 ... tripping acc to iec 60898-1 this graph shows trip-time versus overcurrent for type c ...
|
| | i n t 1 h t=25 °c 2.0 i n t 12 120 s t=25 °c 300 120 60 30 1.30 3 3 load ... to iec 60898-1 1.20 tr ipping time t [sec 10 3 4 type c 5 i n t 0.1 s 10 i n t ... 0.1 s type d 10 i n t 0.1 s 20 i n t 0.1 s 5 2 1 0.5 0.2 0.1 0.05 ...
|
| | six tripping curves to choose moeller faz ... supplementary protectors are available with six ... tripping characteristics including type b c d k s and z definitions for each ... your application for example low level short-circuit faults in control wiring such as plcs ... are best protected by devices with type b trip characteristics 3 to 5 x ... though not required by nec or cec for supplementary protectors moeller s faz devices are ... cycle current limiting devices offer superior protection by reducing peak let-through ... current and energy this graph shows trip-time versus over-current for all ... faz supplementary protectors discover these advanced ...
|
| | faz supplementary protectors trip characteristic b ... designed for resistive or slightly inductive loads response time of ... ul recognized and csa certified as supplementary protectors for international and ... domestic use conform to iec en60898 type b characteristics suitable for ... where protection against low level short circuit faults in control wiring is ... equipment lighting appliances and some motors low magnetic trip point trip ... b designed for resistive or slightly inductive loads 1 pole neutral 3 poles ... a 6 8 10 12 13 15 16 20 25 32 40 50 63 type faz-b6/1n faz-b8/1n faz-b10/1n faz-b12/ ... faz-b40/1n faz-b50/1n faz-b63/1n price type faz-b6/3n faz-b8/3n faz-b10/3n faz-b12/ ...
|
| | faz supplementary protectors trip characteristic c ... ul recognized and csa certified as supplementary protectors for international and ... domestic use conform to iec en60898 type c characteristics suitable for ... of device in applications include small transformers lighting pilot devices ... .6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 type faz-c0,5/1n faz-c1/1n faz-c1,6/1n faz- ... faz-c40/1n faz-c50/1n faz-c63/1n price type faz-c0,5/3n faz-c1/3n faz-c1,6/3n faz- ... /3n faz-c40/3n faz-c50/3n faz-c63/3n t [s 7200 3600 1200 600 300 120 60 30 10 5 2 ... .002 0.001 0.0005 1 1.13 1.45 faz-c8/3n see green faz-c10/3n pages faz-c13/3n see ... green pages speci ed non-tripping current int 1.13 x in ... for t 1 h speci ed tripping current it 1.45 x in for t ...
|
| | faz supplementary protectors trip characteristic d ... ul recognized and csa certified as supplementary protectors for international and ... domestic use conform to iec en60898 type d characteristics suitable for ... tripping in high inductive applications such as motors transformers and power ... supplies trip characteristic d designed for ... current in a 6 8 10 13 16 20 25 32 40 type faz-d6/3n faz-d8/3n faz-d10/3n faz-d13/ ... faz-d25/3n faz-d32/3n faz-d40/3n price see green pages 7200 3600 t [s 1.13 1.45 ... 05 0.02 0.01 0.005 0.002 0.001 0.0005 1 speci ed non-tripping current int 1.13 x in ... for t 1 h speci ed tripping current it 1.45 x in for t ... 1 h 2.55 x in t 1 60 s in 32 a t 1 120 s in 32 a type b 3 ...
|
| | faz supplementary protectors trip characteristic k ... ul recognized and csa certified as supplementary protectors for international and ... domestic use conform to iec en60898 type k characteristics suitable for ... the narrow range compared with the type d curve makes it ideal for applications ... .6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 type faz-k0,5/3n faz-k1/3n faz-k1,6/3n faz- ... faz-k13/3n faz-k16/3n faz-k20/3n price see green pages 1.05 1.30 7200 3600 t [s ... 0.05 0.02 0.01 0.005 0.002 0.001 0.0005 speci ed non-tripping current int 1.05 u in ... for t 1 h speci ed tripping current i 1.30 uitn for t ... 1 h special order these breakers are available by ... special order only contact your moeller ...
|
| | faz supplementary protectors trip characteristic z ... ul recognized and csa certified as supplementary protectors for international and ... domestic use conform to iec en60898 type z characteristics suitable for ... applications where semiconductors and other components that fail open are ... 3 x continuous rating of device in the short thermal delay and low magnetic trip ... where devices and components have low surge and short circuit tolerances trip ... 1 1.6 2 3 4 6 8 10 16 20 25 32 40 50 63 type faz-z0,5/1 faz-z1/1 faz-z1,6/1 faz-z2/1 ... /1 faz-z40/1 faz-z50/1 faz-z63/1 price type price type price type price faz-z0,5/2 ... 6/2 faz-z2/2 faz-z3/2 faz-z4/2 faz-z6/2 see green faz-z8/2 pages faz-z10/2 faz-z16/ ...
|
| | faz supplementary protectors trip characteristic s ... ul recognized and csa certified as supplementary protectors for international and ... domestic use conform to iec en60898 type s characteristics suitable for ... of device in trip characteristic s designed for control circuits with ... in a 1 2 3 4 6 10 16 20 25 32 40 faz-s1/1 faz-s2/1 faz-s3/1 faz-s4/1 faz-s6/1 ... type price faz-s1/2 faz-s2/2 faz-s3/2 faz-s4/2 type price faz-s10/1 faz-s16 ... /1 faz-s20/1 faz-s25/1 faz-s32/1 faz-s40/1 faz-s6/2 see green faz-s10/2 pages ... faz-s16/2 faz-s20/2 faz-s25/2 faz-s32/2 faz-s40/2 see green pages special ...
|
| | applying branch circuit breakers and supplementary protectors in north america ... faz-nart faz moeller offers two types of miniature circuit breakers for use ... with the molded case circuit breaker standard ul 489 and the canadian equivalent csa ... 22.2 no 5-02 which states that devices within that range can be ... the us and canadian electrical codes a second version faz is recognized per ul 1077 ... and certified per csa c22.2 no 235 as a supplementary protector and can be fully utilized per ... full conformity with the applicable iec standards for miniature circuit breakers en/iec ... aspects of the entire line and should assist in the proper selection and ... of all versions characteristics of iec-style miniature circuit breakers because ...
|
| | supplementary protectors as mentioned the standard ... all of the criteria per code of supplementary overcurrent protective devices or ... supplementary protectors as they are better known ... what is the definition of a supplementary protector per north american standards ... a supplementary protector is a manual reset device ... for opening or closing the circuit source ul 1077 in the us and similarly in ... canada the nec 2005 further defines supplementary protectors as devices intended to ... limited overcurrent protection for specific applications such as lighting fixtures ... message in those definitions is that supplementary protectors are not branch circuit ...
|
| | current rating of each unit ideally suited for resistive loads such as conductors ... response between 5 10 x in ideally suited for inductive loads such as motors and ... solenoids ˇ d instantaneous response between 10 ... 20 x in ideally suited for highly inductive loads such as ... response between 8 12 x in ideally suited for highly inductive loads similar to d ... but with a narrower range ˇ s instantaneous response between 13 17 x ... in ideally suited for highly inductive loads especially ... 2 3 x in very low instantaneous setting to provide tighter protection for loads ... which are more sensitive to the effects of overcurrents a ...
|
| | of a ˝ cycle wave of the available symmetrical current the label on faz-nart devices ... actual let-through energy i2t 45 ka2 s and peak letthrough current 6.2ka at ... 10ka current limiting circuit breakers substantially reduce the amount of damage sustained ... components in the event of a high short circuit fault by clearing the fault in ... the shortest amount of time possible due to the ... quick separation of its contacts and ensuing extinction ... of the arc current hacr and swd faz-nart circuit breakers are also ... in addition the abbreviation swd on the label indicates the devices are ... suitable for switching fluorescent lighting loads on a regular ... basis short circuit markings on faz devices below ...
|