vol 91 smart solutions for remote monitoring and alarms active ethernet i/o with active opc server · distributed active ethernet i/o · modular active ethernet i/o · active gprs i/o · genuine pc-free solutions for monitoring and alarm systems · zero programming with menu-driven logic configurations · active alarm message reports with precise time stamps · support sms/snmp traps/e-mail/tcp/udp/cgi commands · easy integration with active opc server and dll library
|
active ethernet i/o an ideal solution for versatile remote monitoring alarm intrusion detection and alarm systems moxa s iologik active ethernet i/o is a perfect solution for large facility intrusion detection systems the iologik s built-in intelligence allows the i/o device to monitor intrusion signals from motion tilt and optic sensors as well as send out real-time alarms a typical application is an airport intrusion detection and alarm system security around airport runways and terminals require instant alarm notices to be sent to the control center for rapid security responses the iologik can proactively send out alarm messages to the control center ensuring real-time acquisition of intrusion alerts alarms are always reported so system administrators don t need to worry about dropped alarms such as the case with traditional polling mechanisms thanks to click&gotm logic the iologik is also capable of local alarm control application requirements · alarm retrieval from distributed se
|
systems airport intrusion detection and alarm system iologik e2214 active ethernet i/o 6 dis 6 relays · intrusion alarms and instant active reports · click&go logic can reduce fake alarms · active alarm message reports with precise time stamps · versatile alarm media with tcp/udp/snmp trap/email/cgi command/active opc server · di to do local intelligence control for local alarms · menu-driven control logic setting reduces maintenance effort unmanned site monitoring and alarms iologik w5340 active gprs ethernet i/o 4 ais 8 dios 2 relays · quad-band gprs · real-time i/o status active update · versatile alarm media with tcp/udp/snmp trap email/sms · menu-driven control logic setting reduces maintenance effort · dynamic and private ip issue resolved with active opc server · one rs-232/422/485 port for serial-to-gprs communication · sd card for data logging · off-line alarm buffering water pumping station monitoring iologik e4200 modular active ethernet i/o · active alarm messaging · versat
|
click&go logic more power and flexibility with the new generation click&go if-then-else since if-then-else statements are a fundamental part of any programming language even an untrained engineer will be able to use click&go s intuitive if-then-else configuration format to finish an i/o configuration in under five minutes compared with the previous version of click&go more functions are supported for each if-then-else description see the table on page 4 for details ana lo inpu g t wat lever sen el sor rem o actio te n remote action programmers sometimes need to trigger remote digital output based on local analog values in the example shown here a water level sensor was installed in a water tower when the water level drops below a preset level the analog signal from the sensor will be converted to a remote digital output which triggers the pump to turn on although this is a relatively simple example click&go can handle different set points and trigger conditions benefits · only two modu
|
logic if di relay/counter internal register remote action timer schedule host communication fail then do relay/pulse internal register remote action timer snmp trap active message e-mail cgi command sms else do relay/pulse internal register remote action timer snmp trap active message e-mail cgi command sms functions timer click&go supports 24 timers in the control logic users can define these timers for different kinds of applications such as a delay timer delay_on delay_off on_delay off_delay or timer counter all time-based control systems can use this function benefits · time-based control capability · flexibility for actions with the timer function internal register twenty-four modbus registers are available for a user s application and users can change a modbus address from the scada software even when click&go is running the diagram at the right shows how to use scada/custom software to change the internal register with modbus/tcp protocol with this function users can easily inte
|
click&go logic more power and flexibility with the new generation click&go cgi commands cgi commands are based on the http protocol which is the most popular protocol for accessing the internet users will be able to access moxa s i/o devices from anywhere with a simple web browser and can even communicate through firewalls software developers can use cgi commands to integrate i/o functions into their software which is often used with ip surveillance systems moxa s active ethernet i/o products can both send out and receive cgi commands and for this reason are compatible with surveillance devices that support cgi commands benefits · easy to integrate with web-based software · firewall friendly · control i/o from anywhere via web browser surveillance software scada the active ethernet i/o product can send cgi commands to trigger an ip camera to take a snapshot or rotate to different viewing angles the ip camera can send cgi commands to trigger output channels on moxa s active ethernet i/o
|
logic push technologies bring intelligence to your sensors traditional sensor i/o data acquisition requires polling from a central scada system and hmi this method not only increases system burden but also requires polling settings on the scada or hmi by utilizing push technologies or report by exception the iologik enables an event response sensor system and transforms network sensors into intelligent devices that allow system integrators to save valuable time in deployment and programming the iologik supports various kinds of active communication interfaces including tcp udp cgi command email sms snmp trap and active opc server active opc server can reduce network traffic by at least 50 upgrade your hmi/scada system with the brand-new active architecture upgrade your scada from pull to push traditionally opc servers only support the pull architecture for i/o devices this means that your scada system would use a continuous polling method to collect relevant data moxa s active op
|
product showcase active ethernet i/o the smart choice for remote monitoring iologik w5340 active gprs ethernet i/o product features · 4 ais 8 software configurable dios 2 relays · quad-band gprs · programming free if-then-else configuration method increases time-to-market · versatile alarm media with tcp/udp/sms/email/snmp trap · sd card for data logging · off-line alarm buffering · built-in web console · one rs-232/422/485 port for serial-to-gprs communication active opc server resolves private ip communication issues in gprs environments the biggest issue for data acquisition over gprs networks involves the constant changing of private ip addresses this makes the implementation of a gprs solution difficult because the user needs to pay extra fees for a mdvpn mobile data virtual private network service or get a public and fixed ip address to solve this problem the iologik w5340 is equipped with active opc server so users don t need to worry about what kind of ip address they get from
|
and alarms iologik e4200 modular active ethernet i/o product features · compact size slice type form factor for maximum i/o combination flexibility · dual lans for communication redundancy · one rs-232 port for sms alarms · programming-free if-then-else logic reduces time to market · off-line alarm buffering dual lans enhance communication redundancy for a remote monitoring and alarm system the most important consideration is to make sure the alarm can be acquired accurately and immediately the iologik e4200 s active report feature provides real-time monitoring capability and achieves communication reliability with a dual lan design to establish a redundant monitoring and alarm system 8
|
selection guide moxa iologik active ethernet i/o family digital modules iologik e2212 8 dis 8 dos 4 dios · software configurable di or do channels · dry contact or wet contact pnp/npn supported analog modules iologik e2242 4 ais 12 dios · software configurable di or do channels · 150 mv 0 to 150 mv 500 mv 0 to 500 mv 5 v 0 to 5 v 10 v 0 to 10 v 0 to 20 ma 4 to 20 ma · adjustable sampling rate ease of use · programming-free if-then-else control logic · menu-driven configuration interface · web console ease of integration · dll library sdk · active opc server no opc tag creation needed · cgi command for web-based scada iologik e2240 8 ais 2 aos · 150 mv 500 mv 5 v 10 v 0 to 20 ma 4 to 20 ma · adjustable sampling rate · ai to ao signal replication over ip versatile communication methods · tcp/udp · cgi command · email · snmp trap push technology · i/o event report by exception · built-in rtc to provide precise timestamps for alarm messages · save bandwidth by 80 · increase respons
|
iologik e2210 12 dis 8 dos · di or counter mode supported · dry contact or wet contact npn do or pulse output iologik e2214 6 dis 6 relays · 6 form a relays · relay 5a/250 vac or 5a/30 vdc · relay counter for relay usage monitor iologik e4200 modular i/o · supports up to 16 i/o modules di/o 256 points or ai/o up to 64 points · dual lans for network redundancy · sms alarms analog modules · m-3802 8 ai 4 to 20 ma 12-bit · m-3810 8 ai 0 to 10v 12-bit · m-4402 4 ai 4 to 20 ma 12-bit · m-4410 4 ao 0 to 10v 12-bit · m-6200 2 ai rtd · m-6201 2 ai thermocouple digital modules gprs module iologik w5340 4 ais 8 dios 2 relays · quad-band gprs · 150 mv 500 mv 5 v 10 v 0 to 20 ma 4 to 20 ma · data logging · m-1450 4 di 110 vac · m-1451 4 di 220 vac · m-1600 16 di sink 24 vdc · m-1601 16 di source 24 vdc · m-1800 8 di sink 24 vdc · m-1801 8 di source 24 vdc · m-2450 4 relay outputs 24 vdc/230vac · m-2600 16 do sink 24 vdc · m-2601 16 do source 24 vdc · m-2800 8 do sink 24 vdc · m-2801 8 do sourc
|
special offer limited time experience the easy-to-use iologik now iologik e2212 the iologik starter kit package includes · iologik e2212 · evaluation board · power adapter · quick startup guide · iologik instruction video call today for more information please contact our sales representative or worldwide branch in your region send emails to io@moxa.com or visit moxa website at www.moxa.com/io moxa inc moxa americas toll-free 1-888-moxa-usa 1-888-669-2872 tel +1-714-528-6777 fax +1-714-528-6778 usa@moxa.com moxa china shanghai office tel +86-21-5258-9955 fax +86-21-5258-5505 china@moxa.com www.moxa.com www.moxa.com info@moxa.com moxa europe tel +49-89-3 70 03 99-0 fax +49-89-3 70 03 99-99 europe@moxa.com beijing office tel +86-10-6872-3959/60/61 fax +86-10-6872-3958 china@moxa.com shenzhen office tel +86-755-8368-4084/94 fax +86-755-8368-4148 china@moxa.com moxa asia-pacific tel +886-2-8919-1230 fax +886-2-8919-1231 asia@moxa.com © 2009 moxa inc all rights reserved the moxa logo is a r
|