Angular Rate Sensors ENC Series by Murata Manufacturing Co.,Ltd.

More catalogs by Murata Manufacturing Co.,Ltd. | Angular Rate Sensors ENC Series | 11 pages | 2013-07-29

Ads

Contacts for Murata Manufacturing Co.,Ltd.

https://www.murata.com/

Featured catalog pages of Angular Rate Sensors ENC Series

!note · please read rating and !caution for storage operating rating soldering mounting and handling in this catalog to prevent smoking and/or burning etc · this catalog has only typical specifications because there is no space for detailed specifications therefore please review our product specifications or consult the approval sheet for product specifications before ordering s42e.pdf jun.27,2011 angular rate sensors enc series enc-03r 1 this product is an angular rate sensor that uses the phenomenon of coriolis force which is generated when a rotational angular rate is applied to the vibrator murata s original small ceramic bimorph vibrator and simple cap-base structure realize their ultra-small size under 0.1cc their small shape and light weight increase flexibility of installment and help to downsize your equipment this surface mountable device can be mounted by an automatic surface mounter 4.0-0.1 +0.0 0.79 4 3 s features 1 ultra-small and ultra-lightweight 2 quick response 3

!note · please read rating and !caution for storage operating rating soldering mounting and handling in this catalog to prevent smoking and/or burning etc · this catalog has only typical specifications because there is no space for detailed specifications therefore please review our product specifications or consult the approval sheet for product specifications before ordering s42e.pdf jun.27,2011 1 s sample amplifier circuit 4.7µ 3 vcc 4 out njm2115 or equivalent ­ 3v 100k 90k 10k 2 gnd 1 vref high-pass filter 1800p low-pass filter 4.7µ the hiph-pass filter s cut-off frequency in this circuit is approx 0.3hz the low-pass filter s cut-off frequency in this circuit is approx 1khz s application 1 one sensor detects rotation on one axis if two axes are to be detected in the same equipment two different types of sensors emc-03rc and emc-03rd should be used 2 to reduce the effect of temperature drift due to change in ambient temperature a high-pass filter must be connected to sensor

!note · please read rating and !caution for storage operating rating soldering mounting and handling in this catalog to prevent smoking and/or burning etc · this catalog has only typical specifications because there is no space for detailed specifications therefore please review our product specifications or consult the approval sheet for product specifications before ordering s42e.pdf jun.27,2011 packaging s dimensions of reel 1 1110±30 160 min 400 to 560 330±2 100±1 25.5±1.0 29.5±1.0 in mm s dimensions of plastic tape unreeling direction 1.75±0.10 8.4±0.1 c416 7.5±0.1 7° max 8.0±0.1 4.4±0.1 0.3±0.1 2.1±0.1 ø1.5 +0.1 ­0.0 4.0±0.1 2.0±0.1 16.0±0.2 c416 c416 c416 in mm

!note · please read rating and !caution for storage operating rating soldering mounting and handling in this catalog to prevent smoking and/or burning etc · this catalog has only typical specifications because there is no space for detailed specifications therefore please review our product specifications or consult the approval sheet for product specifications before ordering s42e.pdf jun.27,2011 1 notice s storage and operating conditions 1 incorrect handling may affect sensor characteristics please note the following precautions a do not subject the sensor to shock or vibration that exceeds the rated limit b do not install or store the sensor in a location where condensation is likely to form on it c do not install or store the sensor in a location where water may splash directly on it d do not install or store the sensor in a location in which it is likely to be exposed to salt water or corrosive vapor 2 do not use or store the products in a corrosive atmosphere especially where

!note · please read rating and !caution for storage operating rating soldering mounting and handling in this catalog to prevent smoking and/or burning etc · this catalog has only typical specifications because there is no space for detailed specifications therefore please review our product specifications or consult the approval sheet for product specifications before ordering s42e.pdf jun.27,2011 angular rate sensors enc series enc-03w 2 this product is an angular rate sensor that uses the phenomenon of coriolis force which is generated when a rotational angular rate is applied to the vibrator their small shape and light weight increase flexibility of installment and help to downsize your equipment this surface mountable device can be mounted by an automatic surface mounter s features 1 2 axes in 1 package 2 high performance with calibration function in asic · improvement of zero-rate level drift · the reduction of zero-rate level bias · reduction of the change of the

!note · please read rating and !caution for storage operating rating soldering mounting and handling in this catalog to prevent smoking and/or burning etc · this catalog has only typical specifications because there is no space for detailed specifications therefore please review our product specifications or consult the approval sheet for product specifications before ordering s42e.pdf jun.27,2011 s sample amplifier circuit external components 4.7k 5600pf 15 vcc 10µf 560k 270k 2.2µf 2 gyroscope enc-03w 15 7 out x 7 6 ain x 6 5 5 afb x 4 4 apo x asic amp1 sensing element x-axis l r oscillator c memory sensing element y-axis c data processing sw 14 14 sct 0.1µf sw reference 8 amp2 8 vref l r amp2 amp1 1 2 3 16 9 gnd 9 1 2 ,3 ,16 nc 10 10 out y 11 11 ain y 12 12 afb y 13 13 apo y 10µf 560k reference voltage vref is grounded with capacitor of 0.1µf you can set lpf/hpf and gain of the amp.2 with external parts freely x1 to x100 enc-03w includes a charge switch to reset the

!note · please read rating and !caution for storage operating rating soldering mounting and handling in this catalog to prevent smoking and/or burning etc · this catalog has only typical specifications because there is no space for detailed specifications therefore please review our product specifications or consult the approval sheet for product specifications before ordering s42e.pdf jun.27,2011 continued from the preceding page s dimensions of land pattern the land pattern dimensions for smd 1st layer 16 ­0.4 the gnd pattern for electric shield 2nd layer 2 15 ­1.0 3.5 electro circuit pattern prohibition area 1 2.4 2 1.8 14 ­0.7 pin 1 in mm 1 do not make the electro circuit pattern at the prohibition area to prevent contact with the central terminals of product s back side and to prevent interference with the other signal prohibition area the central hatching area at 1st layer 2 please make the gnd pattern for electric shield 2nd layer to reduce interference with the other

!note · please read rating and !caution for storage operating rating soldering mounting and handling in this catalog to prevent smoking and/or burning etc · this catalog has only typical specifications because there is no space for detailed specifications therefore please review our product specifications or consult the approval sheet for product specifications before ordering s42e.pdf jun.27,2011 packaging s dimensions of reel 3 b 3 b ps 6 2 7.0 0 r4 r1 02 r5 0 2.0 .0 0 2.00±0.50 13.00±0.20 b ø254.00±2.00 4.00 ø21 .00 ±0 80 20.00 w1 60 0 4.0 00° 6 w2 w1 13.4±1.0 w2 17.4±1.0 ps ° .00 55 100.00±1.00 r50.00 140.00 in mm s dimensions of plastic tape 1.75±0.1 2.0±0.05 4.0±0.1 unreeling direction ø1.5+0.1 0 12.0±0.2 5.5±0.05 7° max b912 b912 b912 6.3±0.1 6.7 x0123 x0123 x0123 5.4±0.1 5.8 8.0±0.1 ø1.5+0.3 0 1.45±0.1 7° max cover tape trailer components leader part sealed over 100mm empty over 160mm 400 to 560mm reel 160 to 1140mm emboss carrier tape material ps

!note · please read rating and !caution for storage operating rating soldering mounting and handling in this catalog to prevent smoking and/or burning etc · this catalog has only typical specifications because there is no space for detailed specifications therefore please review our product specifications or consult the approval sheet for product specifications before ordering s42e.pdf jun.27,2011 notice s storage and operating conditions 1 incorrect handling may affect sensor characteristics please note the following precautions a do not subject the sensor to shock or vibration that exceeds the rated limit b do not install or store the sensor in a location where condensation is likely to form on it c do not install or store the sensor in a location where water may splash directly on it d do not install or store the sensor in a location in which it is likely to be exposed to salt water or corrosive vapor 2 do not use or store the products in a corrosive atmosphere especially where

!note · please read rating and !caution for storage operating rating soldering mounting and handling in this catalog to prevent smoking and/or burning etc · this catalog has only typical specifications because there is no space for detailed specifications therefore please review our product specifications or consult the approval sheet for product specifications before ordering s42e.pdf jun.27,2011 s minimum quantity part number enc-03r enc-03w ø330mm reel 2000 pcs ­ ø254mm reel ­ 1500 pcs 2 o part numbering angular rate sensors enc series part number en q qproduct id wtype eindividual specification code rpackaging c-03rc w -r e r eu rohs compliant · · · all the products in this catalog comply with eu rohs eu rohs is the european directive 2011/65/eu on the restriction of the use of certain hazardous substances in electrical and electronic equipment for more details please refer to our website murata s approach for eu rohs http www.murata.com/info/rohs.html

!note · please read rating and !caution for storage operating rating soldering mounting and handling in this catalog to prevent smoking and/or burning etc · this catalog has only typical specifications because there is no space for detailed specifications therefore please review our product specifications or consult the approval sheet for product specifications before ordering s42e.pdf