Catalog: Propane and Natural Gas Equipment
Company/Brand: National Energy Equipment, Inc.
|
| | Type CIDV-30 30,000 Specify NG or LP Gas Logs Sets NEE # BTU Fuel Type Shipping ... Control, All Models CIB-2 Automatic Blower PSP511 Pre-programmed thermostat with 4 ...
|
| | is not compromised. Comes with flexible gas connector, fresh air wallcap, flex duct ... applications. Certified to Canadian Gas Association standards by ITL. All units ... come complete with flexible gas connector, flex duct, combustion air ... n Permanently sealed moisture resistant blower motor. n Fully automatic controls with ...
|
| | Igniter P-1163 Ignition Cable P-1240 Blower Assembly For ED40HE P-1290 Smart Valve ... Natural Gas P-1330 Honeywell Natural Gas Valve P-1380 Honeywell Conversion Kit ... 24 Volt Thermostat T822D AC-1070 Steel Gas Connector AC-1071 Neoprene Flexible Gas ...
|
| | cleaning and servicing n Counterflow blower circulates warmth at floor level n ... n 76% A.F.U.E. Available in Natural Gas or Propane. Specify your choice when ...
|
| | (DV Series) NEE # Description DVB-1 Blower Kit for DV10 and DV15 DRB-1 Blower Kit ... piezo system. Add an optional internal blower for even greater circulation. Each ... is the uniquely designed burner. As gas enters the burner port, it is ignited ...
|
| | Wall Furnace NEE # Description GWTB-2 Blower Kit (GWT-50 may use Two Blowers) GWTR-1 ... of the Cost of Electric Heat n Optional Blower n Optional Wall or Built-in ... n High Output Dual Squirrel Cage Blowers n Inshot Burners n Onboard Diagnostics ... for DVE-1, for runs in excess of 54 Gas can heat your home for a fraction of ... the cost of electric heat, and advanced gas heating technology makes these heaters ...
|
| | Room Heaters NEE # Description DRB-1 Blower Kit for RH-25 and RH-35 FRB-3 Blower ... no electricity required. n Optional blower availability factory installed on ... . n Optional manual and automatic blowers. NOTE: Vent Free Heaters are not ... Stand for SR-18 SRB-18 Manual Blower Kit for SR-18 SR18B-18T ... Thermostatically Controlled Blower Kit for SR-18 Accessories for Vent-Free ...
|
| | as well as the 75 gallon natural gas units are manufactured with a cast ... most models feature the new quiet EBM blower design, and have 1 insulation. These ... 57 142 lbs 26 6G40NPVEI 30,000 Natural Gas 40 US, 33.3 Imperial Gallon, 151 L with ... 174 lbs 29 JW502NVH-04 34,000 Natural Gas 50 US, 41.6 Imperial Gallon, 189 L - 22 ... 60 190 lbs 29 6G50NPVEI 34,000 Natural Gas 50 US, 41.6 Imperial Gallon, 189 L with ... 190 lbs 29 6G50-65SNV 65,000 Natural Gas 50 US, 41.6 Imperial Gallon, 189 L - 22 ... 68 186 lbs 32 6G60NPVEI 38,000 Natural Gas 60 US, 50 Imperial Gallon, 227 L with ...
|
| | Gallon all 50 Gallon 81361 Robertshaw Gas Valve, 160 Natural Draft 62635-02 ... Natural Draft 63390 Robertshaw Gas Valve, 160 Power Vent 86483 Starlite ... 71075 Flame Sensor Power Vent 63172 Blower Motor Power Vent 71080 High Limit ... Univ. Thermocouple Natural Draft 07-193 Gas Valve Power Vent 07-474 Thermostat ... 07-100 Flame Sensor Power Vent 09-190 Blower Motor Power Vent 75-07-022 Booster Coil ... for Gas Valve Power Vent 07-174 Air Pressure ... Rod 07-474 Thermostat Control 09-190 Blower Motor AP11114C Thermostat Control ... Valve 63390 Gas Valve 86483 Starlight Ignitor 63172 ... Blower Motor Q390A1095 Thermocouple 81361 Gas ...
|
| | ca Pronto by Rheem the new tankless gas water heater provides a continuous ... overheat limiter. n Built-in electric blower. n Model uses 4 Category III stainless ... (Shown in Inches) Energy Factor NEE # Gas Input BTU/HR Fuel Type Temp. Range ... Lbs) 77 Rise Max. 45 Rise Max. Water Gas RTG-74PVN 19,000 199,900 Natural Gas ... water heater has a built in electric blower to force exhaust gas to the outside. ...
|
| | EQUIPMENT Polaris High-Efficiency Gas Water Heaters Polaris is the quiet and ... of 95-96% and ultra -quiet radial blower and submerged burner, Polaris offers ... and service are easy with all gas valve and blower adjustments factory ...
|
| | : Hot Surface Ignition, Induced Draft Blower, 84% Thermal Efficiency, Pre-Mix Burner ...
|
| | HAXFOR1930 Header O-Ring HAXGSV0001 Gas Valve NG 150-400 HAXGSV0003 Gas Valve ... Immersion Hi-Limit Front IDXBLS1930 Blower Switch IDXBNR1930 Burner/Specify LP Or ... NG IDXBRG1930 Burner Gasket IDXHXA1100 Heat Exchanger Assembly ... Module IDXTST1930 Thermostat IDXVAL1930 Gas Valve POOL SPA HEATERS ...
|
| | speed 30-160 CFM SH0.12 Static, no blower (capacity depending on forced air ... system) 120 CFM SH0.8 Static, no blower (capacity depending on forced air ... system) 80 CFM SHM0.12 Static, no blower (capacity depending on forced air ... dampner 120 CFM SHM0.8 Static, no blower (capacity depending on forced air ...
|
| | Double Throw, for 24 VAC control of blowers and other line voltage loads on ... Double Throw, for 120 VAC control of blowers and other line voltage loads on ...
|
| | 3F01-110 For Regulation of Fan or Blower Control. Close on rise. 10.0/5.0 A 110 ... V AC 3F01-120 For Regulation of Fan or Blower Control. Close on rise. 10.0/5.0 A 120 ... V AC 3F01-130 For Regulation of Fan or Blower Control. Close on rise. 10.0/5.0 A 130 ... V AC 3F01-140 For Regulation of Fan or Blower Control. Close on rise. 10.0/5.0 A 140 ... V AC 3F01-150 For Regulation of Fan or Blower Control. Close on rise. 10.0/5.0 A 150 ... V AC 3F01-160 For Regulation of Fan or Blower Control. Close on rise. 10.0/5.0 A 160 ... V AC 3F01-180 For Regulation of Fan or Blower Control. Close on rise. 10.0/5.0 A 180 ... V AC 3F01-200 For Regulation of Fan or Blower Control. Close on rise. 10.0/5.0 A 200 ... V AC 3F02-136 For Regulation of Fan or Blower Control. Close on rise. 10.0/5.0/25.0/ ...
|