Page 182 of Propane and Natural Gas Equipment by National Energy Equipment, Inc.
CANADAS LEADER IN ENERGY PRODUCTS EQUIPMENT
AO Smith Conservationist Commercial Boilers
Burkay Copper Coil Gas Water Heaters and Boilers feature all non-ferrous waterways. A Burkay Burner maximizes
combustion efficiency.
Features low profile diverter, optimum energy transfer, copper wall combustion chamber. For indoor installation only. These
boilers feature a single stage firing mode, and are not approved for instantaneous applications. All models feature castings that
are made of Bronze or Brass. All water tubes are made from copper. Brazed joints or flare union construction make the heater
immune to the effects of thermal shock and thermal cycling.
A great boiler for domestic hot water supply systems. The combustion chamber is a heat exchanger formed from a two passage
coil of tightly wound continuous copper tube. Water circulating through this coil surrounds the main burner and captures the
radiant heat. A wrap of insulation on the outside of the coil retains the heat captured by the circulating water. Directly above the
coil and the main burner is a compact, horizontal, copper fin tube heat exchanger. The flue gases must pass through this efficient
heat exchanger before leaving the boiler.
This unique Burkay coil and heat exchanger design provide maximum heat transfer and proven field durability. Patented pump
delay system that allows boiler and pump to run simultaneously but delays pump shut off at end of heating cycle to remove usable heat from the heat exchanger and reduce the scale forming tendencies of motionless hot water. Proven pilot ignition system
provides flame failure response in under one (1) second. Redundant high limit controls and gas valves assure safe shutoff in the
event of overheating or flame failure.
AO Smith Conservationist Tank-Type Water Heaters
Features a glass-lined tank, fully automatic controls with safety shutoff, heavy gauge steel jacket, foam insulation,
low nox, easy installation, draft diverter, 150 PSI maximum working pressure, and handhole cleanout.
All internal surfaces of heater that are exposed to water are glass-lined with an alkaline borosilicate composition that is fused
to steel by firing at a temperature range of 1400 F to 1600 F.
Heater is equipped with a 2 3/4 X 3 3/4 boiler-type handle cleanout, and has a working pressure of 150 PSI. Exceeds the
minimum requirements of ASHRAE/IES IES 90.1b-1992 for thermal efficiency and standby loss.
NEE #
BTU
Fuel
Type
Efficiency
Inlet
NPT
Outlet
NPT
Diameter
Height
Width
Weight Recovery Rates
USG at 100 F
HW399
399,000
LP or NG
82%
1 1/2
1 1/2
27
57 1/8
31 1/2
291 lbs
388
HW420
420,000
LP or NG
82%
1 1/2
1 1/2
27
57 1/8
31 1/2
291 lbs
413
HW300
300,000
LP or NG
82%
1 1/4
1 1/4
25 1/4
65
29 5/8
240 lbs
297
HW520
520,000
LP or NG
82%
2
2
27
68 5/16
36 1/2
361 lbs
515
HW670
670,000
LP or NG
82%
2
2
27
67
38 1/2
361 lbs
643
NEE
Capacity
BTU
Fuel Type
Diameter
Height
Width
Weight
Recovery Rates
USG at 100 F
BT80
74 Gallon
75,100
LP or NG
28 1/2
61 1/2
25 3/8
271 lbs
73
BT100
100 Gallon
75,100
LP or NG
29 11/16
69 3/4
26 1/2
350 lbs
73
COMMERCIAL WATER HEATERS
[close]