Page 19 of Propane and Natural Gas Equipment by National Energy Equipment, Inc.
NATIONAL TOLL FREE DIRECTORY 1-866-574-5100
I
ON THE WEB www.nee.ca
Automatic Changeover Regulators
Changeover regulators are an integral two stage regulator with a first stage regulator module that is connected to two cylinders. The regulator is designed to allow
automatic change-over when one cylinder becomes empty, allowing you to change cylinders without interruption of service to the gas appliance. Ideal for motor homes, RVs,
and domestic installations because they maintain reliable uninterrupted service when using two cylinders. Remote indicators are available for some models to allow you to
monitor the cylinder volume at distances up to 10 ft from the regulator.
NEE
Inlet
Connection
Outlet
Connection
Adjustment
Range
Factory
Setting
Bracket
BTU
Capacity
Pigtails
Remote Indicator
PRI1776AFD-1
1/4 Inv. Flare
1/2 F NPT
9-13 WC
11 WC
1776-25
375,000
2- ME1663-20
Direct read
PRI1776AFR-1
2- ME1663-20
1780RT *
PRI1776AFD
2- ME1663-20 *
Direct read
730B
700-1
400,000
2- ME1663-20
N/A
730A
3/8 F NPT
200,000
730C
160,000
254-00
240-32
75,000
862-00 cover
* Included with regulator package
Fisher Commercial Industrial Automatic Changeover Assemblies Manifolds
Changeover Assemblies (Manifold Final Stage Regulator)
Fisher Commercial Changeover Assemblies are designed for large capacity multi-cylinder or tank installations such as bakeries, motels, restaurants and crop dryers. The HSRL-749B and the 64SR/122 first stage manifolds consist of two 64 series
regulators and a direct mounted 803 indicator.
NEE
Inlet
Connection
Outlet
Connection
Adjustment
Range
Factory
Setting
BTU Capacity
Features
HSRL-749B
1/2 F NPT
3/4 F NPT
9 -13 WC
11 WC
1,575,000
With internal relief
64SR/122
1/2 F NPT
5 20 PSI
10 PSIG
1,210,000
Changeover Manifolds (Manifolds Only)
Fisher Commercial Changeover Manifolds are intended for use with second stage regulators and or
separate relief devices which provide the overpressure protection required by code. The capacity of
these manifolds is dependent on the size of the second stage regulator used in the piping system.
NEE
Inlet
Connection
Outlet
Connection
Supply
Setting
Reserve
Setting
BTU
Capacity
Features
R110/21
1/4 Inv Flare
1/4 F NPT
15 PSI
7 PSI
500,000
With indicator
R120/21
1/4 F NPT
45 PSI
30 PSI
1,475,000
Two 67 series regs
749B/21
1/2 F NPT
1/2 F NPT
15 PSI
5 PSI
1,500,000
Two 64 series regs
R110/21
R120/21
749B/21
254-00
PRI1776AFD-1
64SR/122
DOMESTIC REGULATORS
Automatic Changeover Regulators