Page 21 of Propane and Natural Gas Equipment by National Energy Equipment, Inc.
NATIONAL TOLL FREE DIRECTORY 1-866-574-5100
I
ON THE WEB www.nee.ca
High Pressure and Adjustable Regulators
Suitable for liquid or vapor applications with various adjustment options
and spring ranges. Typical applications include torches, construction heaters, power wash heaters, tar pots, etc.
The 67 Series Regulators include a plugged 1/4 F NPT side port for use with
a pressure gauge that is ordered separately.
NEE
Inlet Outlet
Connection
Spring
Range
Set
Pressure
BTU
Capacity
Adjustment Type
67CH-741
1/4 F NPT
50-130 PSI
50 PSI
1,000,000
Handwheel
67CH-742
30-60 PSI
40 PSI
1,200,000
67CH-743
3-35 PSI
20 PSI
750,000
67CH-745
M POL 1/4 F
NPT
3-35 PSI
20 PSI
750,000
67CW-684
1/4 F NPT
50-130 PSI
50 PSI
1,000,000
Wrench
67CW-685
30-60 PSI
40 PSI
1,200,000
67CW-701
50-130 PSI
50 PSI
1,000,000
67CW-687
M POL 1/4 F
NPT
50-130 PSI
50 PSI
1,000,000
67CW-743
1/4 F NPT
3-35 PSI
20 PSI
750,000
67CN-104
Non
Adjustable
15 PSI
600,000
None
67CN-105
20 PSI
750,000
67CN-106
10 PSI
400,000
67CD-101
5-30 PSI
20 PSI
750,000
Dial
67CD-102
20-50 PSI
40 PSI
1,200,000
67CD-103
40-100 PSI
50 PSI
1,000,000
67CD-104
M POL 1/4 F
NPT
20-50 PSI
40 PSI
1,200,000
These high pressure (pounds to pounds) regulators usually reduce tank pressure to an intermediate pressure for use by
another regulator. They may be used as a high pressure regulator on a distribution system when used with a first stage
regulator downstream in the piping system.
The 64SR with internal relief) may be used as a first stage regulator when set at 10 PSI. Suitable for liquid or vapor
at temperatures below 150 F, these regulators are popular for use with crop dryers, high pressure burners and other
medium sized commercial/industrial applications. A 1/4 plugged side outlet can be used to install a pressure gauge or
hydrostatic valve. The 64KB has a special diaphragm protector that makes the unit suitable for NH3 applications.
Fisher 67 Series
High Pressure Regulators
Fisher 64 Series High Pressure Regulators
NEE
Inlet Outlet
Connection
Spring
Range
Set
Pressure
BTU
Capacity
Features
64/222
1/2 F NPT
35-100 PSI
50 PSI
5,250,000
No Relief
64/33
3-15 PSI
10 PSI
2,265,000
64/35
5-35 PSI
20 PSI
3,600,000
64/36
30-60 PSI
40 PSI
4,150,000
64SR/21
3-20 PSI
10 PSI
2,625,000
With
Relief
64SR/22
5-20 PSI
15 PSI
3,000,000
64SR/23
5-35 PSI
20 PSI
3,600,000
NEE
Inlet Outlet
Connection
Spring
Range
Set
Pressure
CFH (NH3)
Capacity *
Features
64KB/33
1/2 F NPT
3-15 PSI
10 PSI
2,265,000
No Relief
64KB/34
5-20 PSI
15 PSI
3,000,000
64KB/35
5-35 PSI
20 PSI
3,600,000
64KB/36
30-60 PSI
40 PSI
4,150,000
64KB/222
35-100 PSI
50 PSI
5,250,000
* Liquid capacity is 145 GPH at inlet pressures 20 PSIG above set point.
64 Series
COMMERCIAL INDUSTRIAL REGULATORS
67CW
67CH
67CD
67CN
[close]