Page 224 of Propane and Natural Gas Equipment by National Energy Equipment, Inc.
CANADAS LEADER IN ENERGY PRODUCTS EQUIPMENT
WHITE RODGERS CONTROLS
Snap Disc Fan Controls
3F01
3F02-125
3L01
3L03-140
NEE #
Description
Amperage
Cut-in
Cut-out
Voltage
3F01-110
For Regulation of Fan or Blower Control. Close on rise.
10.0/5.0 A
110 F (43 C)
90 F (32 C)
120/240 V AC
3F01-120
For Regulation of Fan or Blower Control. Close on rise.
10.0/5.0 A
120 F (49 C)
110 F (43 C)
120/240 V AC
3F01-130
For Regulation of Fan or Blower Control. Close on rise.
10.0/5.0 A
130 F (54 C)
115 F (32 C)
120/240 V AC
3F01-140
For Regulation of Fan or Blower Control. Close on rise.
10.0/5.0 A
140 F (60 C)
120 F (32 C)
120/240 V AC
3F01-150
For Regulation of Fan or Blower Control. Close on rise.
10.0/5.0 A
150 F (66 C)
130 F (32 C)
120/240 V AC
3F01-160
For Regulation of Fan or Blower Control. Close on rise.
10.0/5.0 A
160 F (71 C)
140 F (32 C)
120/240 V AC
3F01-180
For Regulation of Fan or Blower Control. Close on rise.
10.0/5.0 A
180 F (82 C)
160 F (32 C)
120/240 V AC
3F01-200
For Regulation of Fan or Blower Control. Close on rise.
10.0/5.0 A
200 F (93 C)
180 F (32 C)
120/240 V AC
3F01-45
Snap Disc Fan Controls. Close on rise. 125VA pilot duty.
10.0/5.0/25.0/21.6A
45 F (7.2 C)
35 F (1.7 C)
120/240/277 V AC
3F02-125
Fan Control with 24V Anticipator Heater Circuit. Close on rise.
10.0/5.0 A
120 F (49 C)
100 F (38 C)
120/240 V AC
3F02-136
For Regulation of Fan or Blower Control. Close on rise.
10.0/5.0/25.0/21.6 A
135 F (57 C)
90 F (32 C)
120/240/277 V AC
3L01-120
Limit Controls. Open on rise.
10.0/5.0 A
110 F (43 C)
120 F (49 C)
120/240 V AC
3L01-130
Limit Controls. Open on rise.
10.0/5.0 A
115 F (46 C)
130 F (54 C)
120/240 V AC
3L01-140
Limit Controls. Open on rise.
10.0/5.0 A
100 F (38 C)
140 F (60 C)
120/240 V AC
3L01-150
Limit Controls. Open on rise.
10.0/5.0 A
110 F (43 C)
150 F (66 C)
120/240 V AC
3L01-160
Limit Controls. Open on rise.
10.0/5.0 A
120 F (49 C)
160 F (72 C)
120/240 V AC
3L01-170
Limit Controls. Open on rise.
10.0/5.0 A
130 F (54 C)
170 F (77 C)
120/240 V AC
3L01-180
Limit Controls. Open on rise.
10.0/5.0 A
140 F (60 C)
180 F (82 C)
120/240 V AC
3L01-190
Limit Controls. Open on rise.
10.0/5.0 A
150 F (66 C)
190 F (88 C)
120/240 V AC
3L01-200
Limit Controls. Open on rise.
10.0/5.0 A
160 F (71 C)
200 F (93 C)
120/240 V AC
3L01-230
Limit Controls. Open on rise.
10.0/5.0 A
190 F (88 C)
230 F (110 C)
120/240 V AC
3L01-250
Limit Controls. Open on rise.
10.0/5.0 A
210 F (99 C)
250 F (121 C)
120/240 V AC
3L01-300
Limit Controls. Open on rise.
10.0/5.0 A
250 F (121 C)
300 F (149 C)
120/240 V AC
3L01-350
Limit Controls. Open on rise.
10.0/5.0 A
310 F (154 C)
350 F (177 C)
120/240 V AC
3L02-170
Limit Control Manual Reset. Open on rise.
10.0/5.0 A
Manual Reset
170 F (77 C)
120/240 V AC
3L02-180
Limit Control Manual Reset. Open On Rise.
10.0/5.0 A
Manual Reset
180 F (82 C)
120/240 V AC
3L02-190
Limit Control Manual Reset. Open On Rise.
10.0/5.0 A
Manual Reset
190 F (88 C)
120/240 V AC
3L02-200
Limit Control Manual Reset. Open On Rise.
10.0/5.0 A
Manual Reset
200 F (93 C)
120/240 V AC
3L03-140
SPDT Controls. Open on rise.
10.0/5.0 A
140 F (60 C)
120 F (49 C)
120/240 V AC
3L03-190
SPDT Controls. Open on rise.
10.0/5.0 A
190 F (88 C)
170 F (77 C)
120/240 V AC
3L02-190