Page 229 of Propane and Natural Gas Equipment by National Energy Equipment, Inc.
NATIONAL TOLL FREE DIRECTORY 1-866-574-5100
I
ON THE WEB www.nee.ca
MAXITROL MODULATING SYSTEMS
Designed for use with atmospheric and direct fired burners (used in furnaces, ovens, etc). Series 94 is used in either remote or self-contained systems, along with
components common to either configuration. A remote system contains an amplifier with a separate temperature selector. A room override thermostat is optional with remote
single dial selector. The self-contained system has the amplifier/selector combined as a single unit. Common items include temperature sensors, mixing tubes, and modulatormodulator/regulator valves. A dual remote temperature selector is also available and is primarily used for paint booth spray/dry applications. OEM or retrofit applications
include environmental climate control, as well as industrial or commercial heating processes. All fuel gases are compatible with capacities to 30,000,000 BTU/H.
SELECTRA SYSTEMS
Selectra Series 94 Systems
A1094 A1494
AD1094 AD1494
TD94E
TD294E
TS394
TS194
MT2
MT1
T115
* Do not use relay on direct fired applications.
SERIES 94 BASIC SYSTEMS
Description
Amplifier
Remote Selector
Sensor
Optional Override
Valves
Single Dial Relay to operate
automatic valve
A1094
TD94
TS194/MT1 or TS394
T115 (can be used with
TD94E-0409 only)
M420, M520, M620,
M451, M551, M651
Single Dial No relay for automatic valve
A1494
M411, M511, M611,
MR212D, E, G J
Dual Dial No relay for automatic valve
TD294
Not Available
Dual Dial Relay to operate
automatic valve
A1094
M420, M520, M620,
M451, M551, M651
Amplifier Selector
Single Dial Relay to operate
automatic valve *
AD1094C
TS394
Not Available
M411, M420, M451, M511,
M520, M551, M611, M620,
M651, MR212D, E, G J
Single Dial No relay for automatic valve *
AD149CK
K Thermocouple Not
Supplied by Maxitrol
[close]