Page 71 of Propane and Natural Gas Equipment by National Energy Equipment, Inc.
NATIONAL TOLL FREE DIRECTORY 1-866-574-5100
I
ON THE WEB www.nee.ca
Corken Coro-flo regenerative turbine pumps are suited for aerosol applications, cylinder filling, auto gas,
vaporizer feeds, NH3, CO2, SO2 and many other volatile liquid transfer applications.
Features:
n Non-contact, free-floating impeller design that minimizes wear and provides extremely quiet operation.
n Continuous duty rated motors fan-cooled with permanently lubricated ball bearings with no pump shaft bearings that require lubrication.
n Single seal assembly that fits all models and is easily field replaceable.
n Integral motor for installation in tight locations.
NEE
HP
Phase
Max
PSID
Capacity GPM
at 50 PSID
Capacity GPM
at 75 PSID
Inlet
Size
Outlet
Size
C10DD2A
3/4
1
75
6.5
2.5
1 1/4
1
C12FD2A
2
1
85
15
11
1 1/2
1
C12ED2A
1.5
1
85
13
9
1 1/2
1
C13FD2A
2
1
100
22
17
1 1/2
1
C14GD2A
3
3
100
32
25
1 1/2
1
C Series Pumps
The C Series configuration
has the pump close
coupled to a motor.
DS and DL Series Coro-Flo Pumps
These pumps are similar to the F Series Coro-Flo pumps but are built with a foot mounted C Face
bracket that will allow the pumps to be C Face Mounted to various motor configurations to meet a
wider selection of application requirements, related to variations in available voltages, etc.
NEE
(Bare Pump)
Frame Size
Max
PSID
Capacity
GPM at 50 PSID
Capacity
GPM at 75 PSID
Inlet
Size
Outlet
Size
DS9
56C 145TC
75
4.5 w/ 1 HP
2.5
1 1/4
1
DS10
56C 145TC
85
6.5 w/ 1 HP
11
1 1/2
1
DS12
56C 145TC
100
15 w/ 2 HP
17
1 1/2
1
DL13
184TC 215TC
100
31 w/ 3HP
25
1 1/2
1
DL14
184TC 215TC
100
31 w/ 3HP
25
1 1/2
1
CORKEN CORO-FLO PUMPS
Pump Model
Motor HP
Motor Specifications
Motor Model
Couplings required
Bypass Valve Required
DS Series
DS12 DS13
145 TC Frame
C-Face mount
2HP
1 Ph, 115/208-230 Volt, 143TC frame
CL5031T
1ea. N095, N095-1
RO95-78
B166-.75
3 Ph, 208-230/460 Volt, 145TC frame
CM7071T or VM7071T
3 Ph, 575 Volt, 145TC frame
CM7071T-5 or VM7071T-5
3HP
3 Ph, 208-230/460 Volt, 145TC frame
CM7075T or VM7075T
3 Ph, 575 Volt, 145TC frame
CM7075T-5 or VM7075T-5
DL Series
DL13 DL14
182 TC Frame
C-Face mount
3HP
1 Ph, 115/208-230 Volt, 184TC frame
CL5028T
1ea. N095, N095-1
RO95-118
B166-.75 or
B166-1 w/ DL14
3 Ph, 208-230/460 Volt, 182TC frame
VM7026T or CM7026T
3 Ph, 575 Volt, 182TC frame
VM7026T-5 or CM7026T-5
5HP
3 Ph, 208-230/460 Volt, 184TC frame
CM7072T or VM7072T
1ea. N095, ML100-1
ML100-118
3 Ph, 575 Volt, 184TC frame
CM7072T-5 or VM7072T-5
DLF150
182TC to
213 TC
C-Face mount
3-10HP
5HP
3 Ph, 208-230/460 Volt, 184TC frame
CM7072T or VM7072T
1ea. N095, ML100-1
ML100-118
B166-1
3 Ph, 575 Volt, 184TC frame
CM7072T-5 or VM7072T-5
7.5 HP
3 Ph, 208-230/460 Volt, 184TC frame
CM7073T
3 Ph, 575 Volt, 184TC frame
CM7073T-5
10 HP
3 Ph, 208-230/460 Volt, 215TC frame
CM7174T
1ea. N095, ML100-1
ML100-138
3 Ph, 575 Volt, 215 TC frame
CN7174T-5
DLF150
C-Face mount
215TC to 256TC
15-20 HP
w/ 5210 frame
adapter
15 HP
3 Ph, 208-230/460 Volt, 254TC frame
CM7053T
1ea. N095, ML100-1
ML100-158
ZV200-1.25
3 Ph, 575 Volt, 254 TC frame
CM7053T-5
20 HP
3 Ph, 208-230/460 Volt, 256TC frame
CM7059T
3 Ph, 575 Volt, 256TC frame
CM7059T-5
Notes for DS DL
Models
DS DL pumps (excluding
the DLF) are identical except for the frame (motor
to pump mounting bracket). No Mounting base
plate required, bracket is
drilled to mount directly
to the pad. Motor mounting bolts lock washers
are not included. For DS
model requires 4- 3/8
16 bolts 1 long grade 5
For DS model requires 4
1/2 13 bolts 1 1/4 long grade 5. OAL of DS pump
assembly (no motor) 12
11/16 . OAL of DL pump
assembly (no motor) 14
3/32 . All Motors have a
service factor of 1.15. CM
motors have a rigid base,
VM motor have no base
(base not required as the
pump bracket is used for
mounting).
[close]