96 search results for blower in 0.001 seconds found

Fan & Blowers

months from the date of manufacture this warranty applies to fans and blowers which are used within the design parameters and when used in an ... and liability in the event of an operational failure of an nmb fan or blower which was used in a manner specifically approved by nmb nmb will at ... its option repair or replace the defective fan or blower with an identical or functionally equivalent product in no case will

Fan & Blowers

and customer based on customer s request ball bearing fans and blowers may be installed in a horizontal vertical or angled position b bm 1 1 .. value t1 customized value ­ h ­ 6 s ­ a 7 8 1 motor type fal dc blowers 2 core thickness 03 2.7~3.1mm 05 5.8~6.3mm 06 5.5~6.4mm 14 13.5~14.

Fan & Blowers

axial fans ranging in size from 25mm to 173mm dc and ac axial fans and blowers are designed to solve thermal management problems for our oem

Fan & Blowers

.com 818.341.3355 external rotor brushless dc motors the nmb range of blower products has been designed to utilize the benefits of external rotor

Fan & Blowers

723 672 665 670 504 175 1 1 impeller diameter mm 2 fan type r-radial blower 3 height of impeller mm 4 electrical supply d:dc 5 electrical voltage

Fan & Blowers

ps pitot tube for static pressure pn pitot tube for air flow auxiliary blower 6.2

Fan & Blowers

when opening the nozzle and absorbing the air using the auxiliary blower to make the static pressure zero ps 0 the differential pressure pn

Fan & Blowers

life life test data gathered from different types of fans and blowers lends to highly accurate statistical analysis this data can produce

Fan & Blowers

fan motors personal service global reach

Fan & Blowers

innovation through integration minebea company ltd and matsushita motor corporation established in 2004 a new joint venture company under the nmb-mat brand this business integration unites the super-precision instrument processing technology mass production technology and cost competitiveness of min

Fan & Blowers

nmbtc.com 818.341.3355 table of contents common specifications and part numbering system 1.1 1004kl 1.2 1204kl 1.3 1404kl 1.4 1604kl 1.5 1606kl 1.6 1608kl 1.7 1611rl 1.8 2004kl 1.9 2106kl 1.10 2404kl 1.11 2406kl 1.12 2408nl 1.13 2410ml 1.14 2410ml-x 1.15 2415kl 1.16 2810kl 1

Fan & Blowers

nmbtc.com 818.341.3355 about dc motorized impellers 2.1 part numbering system 2.2 101r057 2.3 175r069 2.4 190r071 2.5 220r071 2.6 225r099 2.7 250r100 2.8 280r125 2.9 common specifications and part numbering system 3.1 bm4515 3.2 fal3f 3.3 bm5115 3.4 bm5125 3.5 bm6015 3.6

Fan & Blowers

nmbtc.com 818.341.3355 vibration test conforms to jis c 60068-2-6 amplitude 1.5mm frequency 10 to 55 hz 1 hour in each of the x y and z directions shock test conforms to jis c 60068-2-27 acceleration 981 m/s2 application time 6ms once each in the x y and z directions note 1004kl 1204kl 1404kl

Fan & Blowers

1004kl 25 x 10l nmbtc.com 818.341.3355 auto restart/polarity protection 10m or over with a dc500v megger ac 700v 1s -10°c +60°c operating -40°c +60°c storage non-condensing environment 25°c 50,000 hours b00 inch units mm 7.87 200 min in h2o .24 60 pa rotation .110 4 ­ 2.80.2 .20 50 b50 sta

Fan & Blowers

1204kl 30 x 10l nmbtc.com 818.341.3355 auto restart/polarity protection 10m or over with a dc500v megger ac 700v 1s -10°c +70°c operating -40°c +70°c storage non-condensing environment 25°c 50,000 hours b00 inch units mm rotation .125 4 ­ 3.20.2 7.87 200 min in h2o .40 .32 100 pa b50 80 b4

Fan & Blowers

1404kl 35 x 10l nmbtc.com 818.341.3355 auto restart/polarity protection 10m or over with a dc500v megger ac 700v 1s -10°c +70°c operating -40°c +70°c storage non-condensing environment 25°c 50,000 hours b00 inch units mm rotation in h2o 7.87 200 min pa 40 b30 32 b40 b50 .16 static pressure .

Fan & Blowers

1604kl 40 x 10l nmbtc.com 818.341.3355 auto restart/polarity protection 10m or over with a dc500v megger ac 700v 1s -10°c +70°c operating -40°c +70°c storage non-condensing environment 25°c 60,000 hours b00 inch units mm 7.87 200 min .10 2.7 .09 2.3 8 ­ r3.0 rotation in h2o .20 50 pa .16 40

Fan & Blowers

1606kl 40 x 15l nmbtc.com 818.341.3355 auto restart/polarity protection 10m or over with a dc500v megger ac 700v 1s -10°c +70°c operating -40°c +70°c storage non-condensing environment 25°c 50,000 hours l00 inch units mm .169 4 ­ 4.3 in h2o pa 80 rotation 7.87 200 min static pressure .32 .

Fan & Blowers

1611rl 40 x 28l nmbtc.com 818.341.3355 auto restart/polarity protection 10m or over with a dc500v megger ac 700v 1s -10°c +70°c operating -40°c +70°c storage non-condensing environment 25°c 80,000 hours inch units mm 7.87 200 min in h2o 2.0 1.8 1.6 static pressure 1.4 1.2 1.0 .80 .60 .40 .13

Fan & Blowers

1608kl 40 x 20l nmbtc.com 818.341.3355 pa auto restart/polarity protection b50 static pressure 10m or over with a dc500v megger ac 700v 1s -10°c +70°c operating -40°c +70°c storage non-condensing environment 80 60 40 20 0 0 b40 b30 b20 b10 ps m3/min 0.15 0.30 25°c 50,000 hours l00 air flow .