Catalog: G-2004 Penco General Catalog
Company/Brand: Penco Products, Inc.
how to order catalog in G-2004 Penco General Catalog by Penco Products, Inc.
basic clipper ordering data growth dimension considerations ... several factors contribute to dimensional growth of a continuous row ... of shelving beyond specified dimensions to determine the overall dimension of a ... of shelving employing box posts refer to detail drawings and table below choice ... angle posts at front and rear when ordered as individual component parts the ... using two types of post arrangements how to order clipper units virtually all ... storage needs may be satisfied by ordering standard shelving units as illustrated ... hardware and assembly instructions to order standard shelving units 87 high growth ... 2 determine shelf width and depth 3 order by catalog number as many basic units ... as required to form a continuous row of shelving 4 ...

increase your storage capabilities up to 40 or more penco modular drawers can be ... make this system versatile enough to fill practically any need can be used ... wide range of accessories can be added to existing shelving installations how to ... order modular drawers for shelving a the ... easiest way to order clipper heavy duty modular drawers is ... drawer interior subdivision if you need to order from parts and accessories 1 ... select the size of mounting brackets 2 order drawer front sizes that add up to the ... bracket size 3 order one shelf closure strip per mounting ... bracket kit 4 order partitions dividers plus any ... accessories sized to fit your application color drawers ... anchored wall anchored or cross aisle top tied for floor anchoring clip order ...

frames and beams each is manufactured to exacting tolerances to provide many ... from material handling equipment up to 1000 pounds it is an integral part of ... assembly can be engaged easily without tools and is clearly visible for checking b a ... frame columns are securely mig welded together with channel type braces for maximum ... locking key the design allows for beams to be placed flush with the top or as ... connection which assures positive beam to post alignment along the 8-1/2 length ... tabs extend along the face of the beam to provide extra protection to the prongs ... gauge foot plate is securely welded to each post to provide load distribution ... anchoring from either side of the frame how to select pallet rack a height measure ... pallet load and beam add an extra 4 to 6 clearance between bottom of beam ...

its roll-formed one piece beams to achieve the highest possible strength- ... to-weight ratios in the most frequently desired ... strength protecting the locking key and to accept pressure sensitive labeling each ... with an identifying letter referring to the load bearing capacity beams are ... 5by120 5by126 5by132 5by138 5by144 how to order beams 1 select the required clear ... capacity add up the maximum load to be placed on one pair of beams remember ... span is measured from inside frame to inside frame note beam capacity is ... are stabilized by some form of front to back tie 44 ...

standard on k d lockers lockers may be ordered without legs on all-welded lockers no ... legs is the standard you may order legs or channel bases as an option ... shown for all lockers are for flat top lockers and do not include legs single ... common back is also available up to 18 in depth catalog numbers shown for ... wall mounted 7 8 16 person lockers are ordered by entire units minimum quantities and/ ... or setup charges apply to some lockers sizes contact your penco ... two groups there is much from which to choose knocked down means that the ... our web site ·complete library of penco catalogs ·list of upcoming trade shows ·assembly ... /contents 55 56 locker from a to z 57 lockers finishes standard ... available sizes 76 base options how-to-order 77 all-welded specifications 78 all ...

made from heavy 14 gauge steel sides tops bottoms and shelves are 16 gauge steel ... lockers have full width doors if slope tops are required use hoods all lockers ac ... have rubber bumpers on the latch hooks to reduce noise note each catalog number ... height does not include legs see how to order invincible ii lockers on the next ... page be sure to order a group end for every group of lockers ... 21 24 15 18 21 24 latch guards welded to the door frame prevent tampering 6a143 ...

invincible iitm lockers how to order invincible ii 1 basic units locate the ... row lockers are shown double row [back-to-back configurations are available and are ... provided with a common back and angles to connect the second row of sides to the ... back consult your penco representative order the desired number of frames of the ... if no legs are required specify when ordering note that a single frame of a basic ... side and is not complete until bolted to another locker or until a group end has ... groups and then placed into long rows to end a group or row of lockers order ... with common perforated sides be sure to order a solid end for each row end ... be built in long rows if built in place however groups are difficult to move if they ... consult your installer 4 tier 3 slope top for slope top locksize 4 tier inches ...

z base 4 legs permanently welded to the bottom of the locker for ... base installed can be anchored to floor channel base a permanent ... 4 high channel steel base system to enclose front sides and rear how to ... order all-welded lockers maximum group width ... of the area where the lockers are to be installed remember that you cannot ... a locker frame from a welded group to make it fit 2 make a floor plan ... alternating code the layout drawing to show the location of each type 4 ... you have on the job 5 determine the total desired number of frames of each type ... are required on the job and include the totals on your order 6 after receipt of an ... order for all-welded lockers with the ... no legs or channel base unless they are ordered as an option welded locker growth when ...