Bang-It™ & Woodknocker™ Rod Hanging Systems 04/13 by Powers Fasteners

More catalogs by Powers Fasteners | Bang-It™ & Woodknocker™ Rod Hanging Systems 04/13 | 12 pages | 2015-02-05

Ads

Contacts for Powers Fasteners

Powers Fasteners
2 Powers Lane
Brewster, NY 10509

P: 800-524-3244
F: 877-871-1965
Email: info@powers.com or engineering@powers.com
http://www.powers.com/

Catalog Bang-It™ & Woodknocker™ Rod Hanging Systems 04/13

put your hand in the hand embedded threaded rods in concrete steel threaded rods load capacity for threaded rod carbide hole saw internally threaded insert salt lake city hex threaded inserts for wood carbon steel flanges 3 carbon steel flange carbon steel flange wood to concrete slab 36 carbon steel flange stainless steel wire 304 316 cast in place concrete anchor sleeves conduit to cable tray conduit and cable support 19 34 x 10 12 x 5 34 power carbon rods rod fastener for wood anchoring and fastening system for concrete powers fasteners a36 threaded rod threaded rod a36 internally threaded rod threaded rod 316 concrete anchor systems threaded rod ss carbon rod carbon rods threaded rod 304 zinc threaded rod threaded rod threaded rods 4 threaded rod thread rod threading rod threaded rod grade 8 threaded rod eye all thread rod concrete anchors hammered steel rods 316 13 threaded rod installing threaded rod plastic thread rod hanging rod threaded rod grade 5 threaded rod grade 6 threaded rod grade b steel hex rod 38 threaded rod grade 8 all thread rod wood anchors threaded rod supports threaded rod load capacity threaded rod capacity power fastening

Bang-It™ & Woodknocker™ Rod Hanging Systems 04/13 is listed under these categories

Industrial Supply > Fasteners & Hardware

Featured catalog pages of Bang-It™ & Woodknocker™ Rod Hanging Systems 04/13

bang-it wood-knocker ™ ™ product description bang-it concrete inserts are designed for installation in and through metal composite deck i.e “pan-deck” used to support newly poured concrete floors or roof slabs after pre-drilling the deck and installation the protective sleeve of the insert protrudes below the surface of the deck allowing overhead attachment of steel threaded rod in sizes ranging from 1/4” to 7/8” in diameter the sleeve prevents sprayed fireproofing material and acoustical dampening products from clogging the internal threads of the insert it also prevents burying masking or losing the insert location the hex impact plate offers resistance to rotation within the concrete as a steel threaded rod is being installed wood-knocker concrete inserts are installed onto wooden forms used to support newly poured concrete floor slabs roof slabs or walls when the forms are stripped the color-coded flange is visibly embedded in the concrete

bang-it wood-knocker â„¢ â„¢ material specifications bang-it wood-knocker anchor component component material anchor component component material insert body aisi 1008 carbon steel insert body aisi 1008 carbon steel flange aisi 1008 carbon steel flange engineered plastic spring steel music wire zinc plating astm b 633 yellow dichromate zinc plating astm b 633 yellow dichromate protective sleeve engineered plastic steel specifications material properties for threaded rod steel description steel specification astm rod diameter inch minimum yield strength fy ksi minimum ultimate strength fu ksi standard carbon rod a 36 or a 307 grade c 1/4 to 7/8 36.0 58.0 high strength carbon rod a 193 grade b7 1/4 to 7/8 105.0 120.0 stainless rod type 304 316 ss f 593 condition cw 3/8 to 5/8 65.0 100.0 3/4 to 7/8 45.0 85.0 allowable steel strength for threaded rod allowable tension anchor diameter d in mm area of rod in.2 mm2 1/4 6.4 3/8 9.5 1/2 12.7 5/8 15.9 3/4 19.1 7/8 22.2 0.0491 1.2

bang-it ™ installation specifications bang-it nominal rod/anchor size dimension metal hole saw diameter in drilling speed rpm notation 1/4” 3/8” 1/2” 5/8” 3/4” 7/8” dbit 13/16 13/16 13/16 13/16 13/16 13/16 700-900 700-900 700-900 500-700 500-700 500-700 height of spring in ha 2 2 2 2 2 2 insert thread length in 3/8 5/8 11/16 15/16 1-1/8 1-5/16 length of sleeve in lsl 3-3/8 3-3/8 3-3/8 3-3/8 3-3/8 3-3/8 thread size unc 1/4-20 3-3/8 1/2-13 5/8-11 3/4-10 7/8-9 overall length in l 5-5/16 5-5/16 5-5/16 5-5/16 5-5/16 5-5/16 tsh 5/64 5/64 5/64 5/64 5/64 5/64 steel flange thickness in installation procedure 1 chuck carbide hole saw 2 drill deck holes prior to pouring concrete use the recommended diameter metal hole saw to drill a hole through the metal deck at the location the insert is needed typically inserts are installed in the upper flute valley of the metal deck for easier access during installation however it is also acceptable to

bang-it ™ performance data ultimate and allowable load capacities for bang-it inserts installed in structural lightweight concrete or nominal weight over metal deck1,2,3 rod/insert diameter d in mm embedment depth hv in mm 1/4 6.4 2 50.8 3/8 9.5 2 50.8 1/2 12.7 2 50.8 flute location in deck upper lower upper lower upper lower upper 5/8 15.9 2 50.8 lower upper 3/4 19.1 2 50.8 lower upper 7/8 22.2 2 50.8 lower minimum insert spacing in mm minimum end distance in mm 9 228.6 12 304.8 9 228.6 12 304.8 9 228.6 12 304.8 9 228.6 9 228.6 12 304.8 9 228.6 9 228.6 12 304.8 9 228.6 9 228.6 12 304.8 12 304.8 12 304.8 12 304.8 f´c ≥ 3,000 psi 20.7 mpa allowable load ultimate load tension lbs kn shear lbs kn tension lbs kn shear lbs kn 4,450 20.0 3,320 14.9 5,750 25.9 3,320 14.9 7,110 32.0 3,320 14.9 8,810 39.6 3,960 17.8 3,960 17.8 8,810 39.6 3,960 17.8 3,960 17.8 8,810 39.6 3,960 17.8 3,960 17.8 2,500 11.3 2,500 11.3 3,350 15.1 3,350 15.1 3,350 15.1 3,350 15.1 3,350 15.1 1,115 5.0

wood-knocker ™ installation specifications wood-knocker nominal rod/anchor size dimension notation 1/4” 3/8” 1/2” 5/8” 3/4” 3/8 5/8 11/16 15/16 1-1/8 plastic flange dia in dpf 1-3/8 1-3/8 1-3/8 1-5/8 1-5/8 plastic flange thickness in tsh 7/64 7/64 7/64 7/64 7/64 thread size unc 1/4-20 3/8-16 1/2-13 5/8-11 3/4-10 overall length in l 1-7/8 1-7/8 1-7/8 1-7/8 1-7/8 insert thread length in break-off nail length in ln 3/4 3/4 3/4 3/4 3/4 steel flange thickness in tsh 5/64 5/64 5/64 5/64 5/64 installation procedure 1 set wood-knocker into place 2 hammer in insert prior to pouring concrete over the wood form place the wood-knocker concrete insert break-off nails down on the surface of the wood form at the desired location strike the impact plate of the insert with a hand held hammer until the plastic color-coded flange is flush with the wood surface when all inserts are installed concrete pouring may commence 3 pour concrete and allow to cure after

wood-knocker ™ performance data ultimate and allowable load capacities for wood-knocker inserts installed in normal-weight concrete1,2,3,4 rod/insert diameter d in mm embedment depth hv in mm minimum insert spacing in mm minimum end distance in mm 1/4 6.4 2 50.8 9 228.6 3/8 9.5 2 50.8 1/2 12.7 2 50.8 5/8 15.9 2 50.8 3/4 19.1 2 50.8 1 2 3 4 minimum concrete compressive strength f´c 4,500 psi 31.1 mpa 3,000 psi 20.7 mpa ultimate load allowable load ultimate load allowable load tension lbs kn shear lbs kn tension lbs kn shear lbs kn tension lbs kn shear lbs kn tension lbs kn shear lbs kn 6 152.4 3,720 16.7 1,490 6.9 1,240 5.6 495 2.2 4,250 19.1 1,610 7.2 1,415 6.4 535 2.4 9 228.6 6 152.4 4,820 21.7 5,330 24.0 1,605 7.2 1,775 8.0 7,190 32.4 5,620 25.3 2,395 10.8 1,875 8.4 9 228.6 6 152.4 4,820 21.7 7,400 33.3 1,605 7.2 2,465 11.1 7,190 32.4 8,590 38.7 2,395 10.8 2,865 12.9 9 228.6 6 152.4 4,650 20.9 1,550 7.0 8,440 38.0 2,815 12.7 12 304.8 9 228.6 4,650 20.9 11.360 51.1

bang-it wood-knocker ™ ™ performance data underwriter’s laboratories ul and factory mutual fm global ultimate load capacities for bang-it inserts installed in lightweight concrete over metal deck1,2,3,4 1 2 3 4 rod/insert diameter d in mm embedment depth hv in mm maximum pipe diameter in mm 3/8 9.5 2 50.8 4 101.6 1/2 12.7 5/8 15.9 2 50.8 2 50.8 8 203.2 12 304.8 f´c ≥ 3,000 psi 20.7 mpa flute location in deck ul test3 lbs kn fm test4 lbs kn upper 1,500 6.8 1,450 6.5 lower 1,500 6.8 1,450 6.5 up per 4,050 18.2 upper 3,800 17.1 7,900 35.6 the values listed above are ultimate load capacities which should be reduced by a minimum safety factor of 3.0 or greater to determine the allowable working load nfpa 13 fire protection fastening requirements are five times the weight of the liquid water filled pipe plus 250 lbs consult the engineer of record underwriters laboratories ul – file no ex1289 recognized and suitable for use in air handling spaces factory

bang-it wood-knocker ™ ™ ordering information bang-it deck insert unc cat no description color code pre-drilled hole std box std pallet 7540 1/4” bang-it brown 13/16” 100 4,000 7542 3/8” bang-it green 13/16” 100 4,000 7544 1/2” bang-it yellow 13/16” 100 4,000 7546 5/8” bang-it red 13/16” 50 2,400 7548 3/4” bang-it purple 13/16” 50 2,400 7549 7/8” bang-it black 13/16” 50 2,400 bang-it installation accessories cat no description std box 7560 bang-it stand up pole tool 1 7562 13/16” carbide hole saw for 1/4” 3/8” and 1/2” sizes 1 7564 13/16” carbide hole saw for 5/8” 3/4” and 7/8” sizes 1 7566 extra carbide hole saw center bit 1 wood-knocker form insert unc cat no description color code std box std pallet brown 200 9,600 7550 1/4” wood-knocker 7552 3/8” wood-knocker green 200 9,600 7554 1/2” wood-knocker yellow 200 9,600 7556 5/8”

bang-it inserts for concrete over metal decking wood-knocker inserts for wood formed concrete slabs powers fasteners inc rawl anchoring into concrete and lightweight concrete ideal for concrete form pours a one piece banger-type cast-in-place insert a fast safe and user-friendly method to hang rod overhead simple installation reduces costs and improves efficiency zinc plated carbon steel with engineered plastic color coded flange and sleeve allows for size identification available sizes of 1/4” to 3/4” in diameter bang-it available in 7/8” dia project submittal product substitution form product description and general information engineering data and material properties system components and accessories guide specifications and approvals product approvals factory mutual research corporation fmrc file no j.i 3015153 underwriters laboratories ul file no ex1289 recognized for use in air handling spaces suitable for seismic and wind load applications acceptable for

product submittal substitution request to project specified item section page paragraph description production submittal subsitution requested the attached submittal package includes the product description specifications drawings and performance data for use in the evaluation of the request submitted by name signature company address date telephone fax for use by the architech and/or engineer ❑ approved ❑ approved as noted ❑ not approved if not approved please briefly explain why the product was not accepted by date remarks

powers fasteners branch information usa locations powers branch information city alabama atlanta boston charlotte chicago dallas denver detroit florida houston indianapolis kansas city st louis los angeles maryland milwaukee minneapolis nashville/memphis new orleans new york philadelphia phoenix pittsburgh portland rochester salt lake city san francisco seattle address contact phone fax 5405 buford hwy suite 410 norcross ga 30071-3984 5405 buford hwy suite 410 norcross ga 30071-3984 2 powers lane brewster ny 10509 349 l west tremont avenue charlotte nc 28203 2472 wisconsin avenue downers grove il 60515 1300 ih 35 north suite #118 carrollton tx 75006 2475 west second street #35 denver co 80223 21600 wyoming avenue oak park mi 48237 2412 lynx lane orlando fl 32804 13833 north promenade suite 100 stafford tx 77477 15290 stony creek way noblesville in 46060 716 east 16th avenue north kansas city mo 64116 2761 dow avenue tustin ca 92780 3137-b pennsy drive landover md 20785 12020 w