Nuclear Medicine Products 2008/2009 by PTW

Catalogue: PTW Nuclear Medicine Products 2008/2009
Catalog: Nuclear Medicine Products 2008/2009
Company/Brand: PTW

Flippable HTML catalog

PDF catalog

Flippable Flash catalog

Visitor statistics

PTW Contact Information

PTW-New York Corporation
205 Park Avenue
Hicksville, New York 11801
USA

Phone (1-516) 827 3181
Fax +1 516 827 3184
ptw@ptwny.com
http://www.ptw.com

Searched and found

04 pet 18f activities of up to 92 gbq 2008 2009 electrical 2009 accord performance 28 mm acrylic cylinder acrylic cylinder nuclear medicine auto reset auto start bar phantom class c curiementor display units dose calibrator double door dimensions flow hot gamma camera glass door seal for double doors glass windows hot cell insert for tube internal doors for houses ionization chambers lab equipment lab product label printer medicin medicine medicines nema products nuclear nuclear medicine nuclear medicine hot cell nuclear medicine phantom nuclear medicine phantoms pet products plastic liners prism 1500 product line ptw ptw 30 radiation protection radiation protection detector calibration radiopharmaceutical safety hinges for a door sliding door system sliding doors system standard measuring devices survey meters use or purpose of the test tube used nuclear medicine gamma spect cameras video monitor video monitors wall display unit x ray test equipment

Similar catalogs to Nuclear Medicine Products 2008/2009

Nuclear Medicine Products 2008/2009 is listed here

Selected page of Nuclear Medicine Products 2008/2009

nuclear medicine introduction nuclear medicine basics since the discovery of x-rays in 1895 by röntgen and uranium radioactivity in 1896 by becquerel the use of ionizing radiation in medicine has undergone fascinating development nuclear medicine started in 1937 with the first clinical use of artificial radioactivity for treating a patient with leukemia today there are nearly one hundred different nuclear medicine procedures that provide information about virtually every major organ system within the body modern computer based techniques such as pet positron emission tomography and spect single photon emission computed tomography offer methods for diagnostic imaging that are unique by documenting dynamic organ function and structure pet is rapidly becoming a major diagnostic imaging modality pet images demonstrate the chemistry of organs and other tissues such as tumors a radiopharmaceutical especially fdg fluorodeoxyglucose marked with the positron emitting isotope 18f is injected


nuclear medicine isotope calibrators curiementor® 4 pet system radioactive check device isotope calibrator for high activity measurement in pet nuclide production features measures high activities in pet nuclide production displays measuring results continuously for isotopes with very short half-life time stores the nuclide calibration factors non-volatile features auto-start auto-print and auto-reset functions complies with iec 61145 the process for the production of nuclides used for applications in pet positron emission tomography creates high nuclide activities especially the production of the 18f isotope which is included in the fdg radiopharmaceutical fluordeoxyglucose and the 15o isotope require an isotope calibrator suited for high activity measurement the pet curiementor 4 isotope calibrator includes a well ionization chamber with argon gas filling at 1,5 bar pressure the geometrical design of the pet chamber is identical to the standard chamber design the 18f measuring range


nuclear medicine quality control quality control quality control equipment pet cylinder phantom acc nema nu2-2007 pet sensitivity phantom acc nema nu2-2007 pet emission phantom acc nema nu2-2007 spect phantom acc iec 61675-2 pet emission phantom acc cec project pet emission phantom acc iec 61675-1 dynamic heart phantom animal pet qc phantoms standard spect phantom thyroid uptake neck phantom flood phantoms for qc of gamma cameras flood phantom positioning carts atw3 shielded transportation cart tungsten bar phantom for gamma camera qc quasi 3 orthogonal hole phantoms 13 13 14 14 15 15 16 16 17 17 18 19 19 20 20 11


nuclear medicine quality control equipment pet emission phantom acc nema nu2-2007 spect phantom acc iec 61675-2 body-mimicking emission phantom for realistic quality control of pet scanners acc nema nu2-2007 features simulates realistic conditions by utilizing a body-shaped acrylic vessel includes a cover with six spherical inserts and an absorber inserts can be filled and emptied from outside complies with section 7 of nema nu2-2007 the pet emission phantom l981606 complies with the phantom design of the nema standard nu2-2007 the phantom is described in section 7 image quality accuracy of attenuation and scatter corrections it has the same asymmetric shape as the cec and the iec body phantom and simulates the human body in the range of thorax and abdomen a circular cover with six mounted hollow glass spheres completes the phantom the inner active diameters of the spheres are 10 mm 13 mm 17 mm 22 mm 28 mm and 37 mm and the wall thickness is approx 1 mm the hollow spheres can be fill


nuclear medicine quality control equipment standard spect phantom thyroid uptake neck phantom compact acrylic phantom for quality control of spect systems features checks the resolution by acrylic rods of different diameters checks the contrast by acrylic spheres of different diameters checks the inhomogeneity by homogeneous radioactivity distribution the standard spect phantom is used for the determination of the tomographic specifications of spect systems the phantom consists of a circular acrylic vessel of 200 mm diameter and 214 mm height including various test inserts three parameters can be checked simultaneously during one measuring cycle the tomographic resolution is tested by a number of acrylic rods of different diameters located in six phantom sections the rod diameters are 4.0 6.0 8.0 10.0 12.0 and 15.0 mm the tomographic contrast is tested by six fully acrylic spheres with diameters of 9.5 14.4 19.0 25.4 31.8 and 38.1 mm simulating cold spots the tomographic inhomo


nuclear medicine quality control equipment tungsten bar phantom quasi 3 orthogonal for gamma camera qc hole phantoms tungsten bar phantom for spatial resolution and linearity tests of planar gamma cameras features checks the spatial resolution and the linearity of planar gamma camera images in nuclear medicine ensures high precision by utilizing tungsten cast bars includes four resolution quadrants suitable for all current gamma camera models the unique bar phantom uses tungsten bars instead of lead bars to achieve higher precision in spatial resolution and linearity tests of gamma cameras with planar scintillation crystal the phantom consists of four quadrants with different bar specification imbedded lead plates with hole matrix for geometry tests of gamma cameras for planar scintigraphy features enable users to perform geometric tests on gamma cameras four phantom types with different hole diameters are available the quasi 3 orthogonal hole phantom is used for constancy tests of sin


nuclear medicine radiation monitoring equipment step survey meter bleeper personal monitor compact portable ion chamber dosemeter for dose and dose rate measurements of x and gamma radiation features serves for protection level dosimetry in a wide energy range of 6 kev to 7.5 mev of x-rays and gamma rays displays the reading on a backlit lcd shows very low energy and directional dependence provides wide measuring ranges for radiation protection levels dose 2 2000 µsv dose rate 2 µsv/h 2msv/h measures continuous and pulsed radiation the approved step survey meter is used for protection level dosimetry in nuclear medicine laboratories and in the environment nuclear medicine therapy patients can be checked before release the instrument is based on a 600 cm3 large volume ionization chamber which provides high precision and a wide range of health physics measurements the wall reinforcement cap can be removed for low energy measurements down to 6 kev the unit is prepared for chamber volu


nuclear medicine pet laboratories pet laboratories pet lab equipment hot cells 29 dispensing systems 31 waste management 32 cyclotron bunker equipment 32 hot lab accessories 33 27


nuclear medicine pet lab equipment manipulation hot cells with laminar flow manipulation hot cell for 68ga handling manipulation hot cells for pet/spect radioisotopes to work in gmp-compliant conditions nmc/dds-vf manipulation hot cell this is a vertical laminar flow shielded cell specifically designed for preparing fdg doses of pet diagnostic and conventional nuclear medicine isotopes both manually and automatically produced in accordance with gmp procedures the high efficiency of hepa filters together with the vertical laminar flow assure a class a environment and high sterility conditions a lead glass window is installed on the door for a complete sight of the whole working area when opening the shielded door an acrylic panel is closing the box airtight which enables the operator to install disposable kits in airtight conditions easily nmc1/50-50 fdg manipulation hot cell this hot cell is designed for radionuclide and radiopharmaceutical storage and manipulations required in nuclear


nuclear medicine pet lab equipment hot lab accessories all kinds of shielding for vials syringes refrigerators storage and waste containers bl-t workbench for target maintenance the bl-t consists of a working surface in stainless steel with a supporting frame of painted steel a mobile shield model bbs2 eq pb 20 mm can slide on the workbench the lower part of the bench contained in the supporting frame is open and provided with shelves crs radioactive waste containers crs is used to store solid radioactive waste it is made of stainless steel and alternatively shielded with 2 5 or 10 mm lead plates two types of 20 and 75 liters volume are available both supplied with a footswitch ars shielded cabinet for storage frs refrigerator the ars shielded cabinet is suitable for safe storage of small-size sources radioactive phantoms radiopharmaceuticals etc all internal trimmings are made of stainless steel the external surface is made of steel painted with decontaminable epoxy resins the frs s


africa egypt morocco south africa america argentina brazil canada chile colombia costarica ecuador mexico panama uruguay usa venezuela asia bahrain bangladesh china hong kong india indonesia iran israel japan jordan korea lebanon philippines saudi syria taiwan australia australia europe austria the objective from the start was to be a trustworthy and competent partner for our customers throughout the world this also includes maintaining quality standards and comprehensive service and support we will continue to do everything possible in the future to manufacture high-quality dosimetry products which users and patients can trust we know what responsibility means malaysia pakistan arabia singapore thailand vietnam and new zealand belarus belgium bulgaria cyprus czech republic denmark finland france germany greece hungary iceland italy malta netherlands norway poland portugal romania russia slovakia spain sweden switzerland turkey ukraine united kingdom ptw-freiburg physikalisch-technisch


All copyrights remain by their owners. Who-sells-it.com is not an official partner of PTW.
 



Home | Latest catalogs | Contact

© 2006-2009 by who-sells-it.com