Catalog: Radiation Medicine QA Solutions 2008/2009
Company/Brand: PTW
high energy support in Radiation Medicine QA Solutions 2008/2009 by PTW
check devices are recommended for high precision dosimetry they enable medical ... format two versions are available to support all established international therapy ... determine the absorbed dose to water of high-energy photon and electron radiation out of ... unisoft software edition 2000 supports the aapm tg-51 and iaea trs-398 therapy ...
calibration of ionization chambers in highenergy photon and electron beams suitable for ... for easy carrying three adjustable supports for leveling etched cross hairs for ... calibration of ionization chambers in high-energy photon and electron beams suitable for ... for easy carrying three adjustable supports for leveling etched cross hairs for ...
calibration of ionization chambers in high-energy photon and electron beams suitable for ... on the opposite wall which serves as support the adapter is fixed adapters are ... for easy carrying three adjustable supports for leveling etched cross hairs for ... closed stationary water phantom for high energy photon dosimetry with ptw farmer ...
diode mate mobile unit ceiling mounted support to accommodate in-vivo diode detectors ... up to 12 in-vivo probes for high-energy photon and electron dose measurement ... 12 probes is approximately 28 kg mobile support to accommodate invivo diode detectors ... up to 12 in-vivo probes for high-energy photon and electron dose measurement ... range the diode mate is 1275 mm high the outer diameter is 550 mm the weight ...
of depth dose curves features high precision 1d water tanks for absolute ... dosimetry and depth dose measurement of high energy photon and electron beams comply ... alignment and fill lines and adjustable supports for leveling the mp1 mp1-s and mp1-m ... each phantom has three adjustable supports for levelling and a collision-protected ... profiles and depth dose curves of high-energy photon and electron beams in solid ...

portal imaging devices used in high-energy photon beams features suitable for ... checks linearity isotropy noise low and high contrast resolution with test elements ... in focal spot geometry high contrast resolution in horizontal ... constant image quality and thus a high safety level for the patient the epid ... checks linearity isotropy noise low and high contrast resolution in a focal spot ... the phantom includes a wide range of highcontrast test patterns to perform tests even of ... functions for all relevant parameters supports file formats of all established epids ...

for use in the open air a special support made of aluminum is used to set up the ... and mobile radiation monitoring of high level gamma radiation features vented ... construction for wall mounting gamma energy range 80 kev to 1.3 mev the 0.1 liter ... the chamber is designed to measure very high dose rates of up to 4000 sv/h 90 ... monitoring chamber 0.1 l option t8602 support for moderator sphere albedo neutron ...
each delivering only one radiation energy or an x-ray tube delivering a range of ... x-ray energies by varying the high voltage and filter settings different x ... in front of the x-ray tube a stable support is required to install the x-ray tube ... by the iaea the international atomic energy agency vienna as a member of the iaea/ ...