Catalog: Radiation Medicine QA Solutions 2008/2009
Company/Brand: PTW
ionization chambers in Radiation Medicine QA Solutions 2008/2009 by PTW
electrical equipment dosemeters with ionization chambers as used in radiotherapy ... electrical equipment dosemeters with ionization chambers and/or semiconductor detectors ...
brachytherapy dosemeter semiflex ionization chambers rigid stem ionization chambers ... ptw farmer ionization chambers sealed ionization chambers pinpoint ionization chambers ... diodes diamond detector microlion ionization chamber bragg peak ionization chambers ... roos electron chamber soft x-ray ionization chambers soft x-ray slab phantom ... dosimetry software build-up caps for ionization chambers estro mini phantoms acrylic ...
health physics chapter when ordering ionization chambers please specify the desired ... trs-381 the use of plane parallel ionization chambers in high energy electron and ... a wide range of top level dosemeters ionization chambers solid state detectors check ... are bnt tnc and ptw-m upon request the chambers and connection cables can optionally be ...
ms variable voltage supply accepts ion chambers and solid state detectors to be ... high resolution for small size ion chambers the tandem electrometer is calibrated ... field measurements referenced to an ionization chamber in conjunction with a tba ...

absolute dosimetry equipment semiflex ionization chambers rigid stem ionization chambers ... waterproof thimble chambers for measuring high-energy photon and ... within a wide energy range the semiflex chambers are designed for therapy dosimetry ... device is available as an option both chambers are shaped cylindrically with an inner ... three axes of a water phantom thimble chambers for measuring highenergy photon and ... 0.3 cm3 and 1 cm3 suitable as reference chambers for use in solid phantoms very flat ... within a wide range the rigid stem chambers are designed as reference chambers for ... and 6 mev to 50 mev electrons both chambers are shaped cylindrically thimble ... chambers the wall material is graphite with a ... up to the measuring volume both chambers are constructed with a long stem of ...

dosimetry equipment ptw farmer® ionization chambers waterproof ptw farmer® chamber ... thimble chambers for measuring highenergy photon and ... volumes of 0.6 cm3 suitable as therapy chambers for use in solid phantoms flat energy ... is available the 0.6 cm3 ptw farmer chambers are designed for absolute photon and ... 50 mv the electron energy range of all chambers is from 6 mev to 50 mev the chambers ... 166 ordering information ptw farmer chambers with connecting system bnt tnc or m ...

absolute dosimetry equipment sealed ionization chambers pinpoint® ionization chambers ... waterproof and flexible ion chambers with sensitive volume sealed against ... patient contact the flexible 0.1 cm3 chambers are to be used in environments with ... according to iec 60731 therefore the chambers are ideal for in-vivo measurements ... rectum using a protective sleeve the chambers are to be used with a radioactive check ... can be obtained by interpolation the chambers are equipped with a flexible stem the ... of chamber type 23323 is 7 mm the chambers are supplied with a flexible cable of 1 ... with each chamber waterproof ion chambers for dose measurements in radiotherapy ... use in water the waterproof pinpoint chambers have been specially designed for ... resolution is desired the pinpoint chambers are ideally suited for this purpose ...

absolute dosimetry equipment microlion ionization chamber bragg peak ionization chambers ... lic concept waterproof plane-parallel chambers for dosimetry in proton beams features ... 2.5 cm3 vented to air the bragg peak chambers are designed to measure the exact ... proton beams the large diameters of the chambers allow the measurement of the complete ... including the scattered protons the chambers are waterproof and consequently can ... water phantom in water both bragg peak chambers can be used for measurements of ...
no trs-381 the use of plane parallel ionization chambers in high energy electron and ... vienna 1997 ordering information markus chambers connecting system bnt tnc or m 34045 ...
absolute dosimetry equipment soft x-ray ionization chambers soft x-ray slab phantom plane ... parallel chambers with thin membranes for measuring ... -ray chamber type 23342 is the standard ionization chamber for dose measurements in ... required the usual calibration of both chambers is done at 15 kv to 70 kv the chambers ... soft x-ray dosimetry with soft x-ray chambers features suitable for soft x-rays up to ... purposes using the soft x-ray chambers type 23342 0.02 cm3 or 23344 0.2 cm3 ... for chamber type 23344 soft x-ray ionization chambers page 22 ordering information ... soft x-ray chambers connecting system bnt tnc or m 34013 ...

density corrections when using vented ionization chambers check proper functioning and ... two types for thimble and flat chambers are available include encapsulated low ... physicists to check the stability of ionization chamber response and to determine air ... correction factors for sealed in-vivo ionization chambers the use of a radioactive check ... for the adaptation of different ion chambers are available due to the arrangement of ... near to the entrance window of flat ion chambers by means of the appropriate holding ... out of dosemeter readings from ionization chambers based on 60co calibrations ... dosimetry protocols unisoft features ionization chamber libraries to store chamber data ... protocols beam qualities types of ionization chambers and two kinds of air density ...

dosimetry equipment build-up caps for ionization chambers estro mini phantoms acrylic ... and brass build-up caps for thimble chambers for use in highenergy photon beams ... suitable for ptw farmer and semiflex chambers made of acrylic or brass build-up caps ... are used with thimble ionization chambers for in-air measurements in photon beams ... -up caps is available for different ionization chamber types and for different photon ... the chamber types 0.6 cm3 ptw farmer chambers 0.125 cm3 and 0.3 cm3 semiflex ... chambers the acrylic build-up caps are designed ... types 0.125 cm3 and 0.3 cm3 semiflex chambers the wall thicknesses cover the energy ... build-up caps upon request semiflex ionization chambers page 16 ptw farmer ionization ... chambers page 17 24 ...

for tip-to-tip calibrations of therapy chambers features suitable for chamber ... rate makes it possible to calibrate chambers using the tip-to-tip or the replacement ... makes it possible to place thimble chambers in measuring depths of 50 mm 70 mm and ... preferred calibration method if both chambers are of the same type a variety of ... adapters for a number of ionization chamber types is available the phantom ...

features suitable for calibration of ionization chambers in highenergy photon and ... it possible to irradiate up to three chambers simultaneously makes it possible to ... using a horizontal beam up to three ionization chambers alternatively tl detectors and ... make it possible to position the chambers precisely by means of adapters in ... features suitable for calibration of ionization chambers in high-energy photon and ... it possible to irradiate up to three chambers simultaneously makes it possible to ... using a horizontal beam up to three ionization chambers alternatively tl detectors and ... enable users to position thimble chambers precisely in depths from less than 15 ... to 260 mm and plane parallel electron chambers as well as thermoluminescent detectors ...

features suitable for calibration of ionization chambers in high-energy photon and ... are available for a variety of thimble chambers the measuring position is 150 mm below ... energy photon dosimetry with ptw farmer chambers features makes it possible to perform ... mm the measuring depth 50 mm ptw farmer ionization chambers fit exactly into the built-in ... stationary water phantom ptw farmer ionization chambers page 17 ordering information ... t41001.1.005 adapter for ptw farmer chambers t41001.1.006 adapter for chamber 31002/ ... t41001.1.007 adapter for chamber 31006 ionization chambers pages 16 and 17 27 ...
to supply adjustable high voltage to ionization chambers features precise adjustable ... voltage supply it can be used for all ionization chambers which need a high chamber ... information t16036 hv-supply for ionization chambers microlion chamber page 20 28 ...
a multi-channel dosemeter compared with ionization chambers semiconductor detectors have ...
multidos can be used with ionization chambers and semiconductor detectors it meets or ...
dosimetry probes and reference chambers is available the afterloading ... of adapters for applicators probes and chambers is available ordering information t9111 ... afterloading probes and reference chambers upon request afterloading probes page ... 37 ionization chambers pages 16 and 17 options l981064 cable ...
unidos® in-vivo dosemeter well-type ionization chamber for afterloading source ... to determine the response of sealed ion chambers as required by iec 60731 is available ... account there are two types of flexible ionization chambers with 0.1 cm3 measuring volume ...
sourcecheck optional accessories flat ionization chamber for measuring the source ... bias voltage supply the sourcecheck ionization chamber is the ideal device for ... check device available the sourcecheck ionization chamber provides the possibility of ...
to mount semiflex farmer and electron chambers to the moving mechanism are available ... plexitom 0.125 cm3 ion chamber adapter ionization chambers pages 16 and 17 therapy ...
bias voltage supply accepts ion chambers and solid state detectors to be ... high resolution for small size ion chambers the tandem electrometer is calibrated ... field measurements referenced to an ionization chamber in conjunction with a tba ...
used for simple installation of various ionization chambers and detectors in tba systems ... on the water surface in water phantoms ionization chambers and solid state detectors for ... farmer chamber can be used the pinpoint chambers with their small sensitive volumes of 0 ...
principle a transparent multiwire ionization chamber mic is installed below the mlcs ... is a transparent segmented multiwire ionization chamber mic measurement wires are ...
embedded in a solid state phantom the ionization chambers feature an excellent relative ... l981366 starcheck system with 527 ionization chambers incl interface software option ...
qa features 27 x 27 729 vented cubic ionization chambers regularly arranged to mlc ... ageing effects by utilizing ion chambers no radiation damage thanks to separated ... in radiation therapy utilizing ion chambers avoids radiation defects the major ... detectors the vented plane-parallel ion chambers are 5 mm x 5 mm x 5 mm in size and the ... is 10 mm in total there are located 729 chambers in a matrix of 27 x 27 providing a ... be moved 5 mm to close the gaps between chambers by shifting the array 3 times the whole ... l981359 2d-array seven29 with 729 chambers incl array interface and data ...
the phantom due to the cutting-edge ionization chamber design the array can be treated ...
using radiographic film and 0.125 cm3 ionization chambers features makes it possible to ... radiographic film and up to five ionization chambers marks the film position by ... beams using a radiographic film ion chambers connected to integrating dosemeters ... cm x 30 cm and up to five 0.125 cm3 ion chambers type 31002/31010 the position of the ... film is 50 mm and the depth of the ion chambers is 60 mm the simple shape of the ... imrt verification phantom semiflex ionization chambers page 16 unidos/unidos e/ ...

system on the films using a needle ionization chamber data can be taken using a hole ... where a 0.125 cm3 or a 0.3 cm3 semiflex ionization chamber can be inserted the phantom can ... of stereotactic imrt beams by semiflex chambers features enables the user to verify ... in a matrix can accommodate semiflex ionization chambers at different phantom locations ... the entire height to place semiflex ionization chambers inside the phantom the ... chambers are inserted up to the desired position ... .1.010 imrt phantom holder semiflex ionization chambers page 16 ordering information ... .1.010 imrt phantom holder semiflex ionization chambers page 16 70 ...
tissue bone lung dose measurement with ionization chamber film or 2d-array seven29 ... t40020.1.010 for use with film or ionization chambers or on the 2d-array seven29 or ...
simultaneously or in two runs 0.125 cm3 chambers model 31002/31010 are placed into holes ... monitor consists of 9 parallel ion chambers and absorbers between the chambers the ... test device and software semiflex ionization chambers page 16 multidos multi channel ...
beam dose simultaneously contains six ionization chambers embedded in acrylic phantom ... patient treatment six plane parallel ionization chambers of 0.54 cm3 measuring volume ... are embedded in an acrylic phantom four chambers on the x and y-axes and two chambers in ... dose measurements from six built-in ion chambers of the qc6plus measuring system and ...
the monitor calibration by inserting an ionization chamber into a hole of the acrylic ... block with a hole to insert a 0.3 cm3 ionization chamber model 31003/31013 adapters for ... correction due to the builtin sealed ionization chamber stores up to 99 measurements ... is a built-in sealed plane parallel ionization chamber no air density correction is ... monitor test device options semiflex chambers connecting system bnt tnc or m 31003/ ... 0.3 cm3 ordering information semiflex ionization chambers page 16 unidos dosemeters ...
electrical equipment dosemeters with ionization chambers as used in radiotherapy ... electrical equipment dosemeters with ionization chambers and/or semi-conductor ...
consists basically of a transparent ionization chamber and a display unit starting in ... between focus and patient plane the ionization chambers can be mounted at any distance ...
the transparent rectangular diadem ionization chamber is mounted directly to the ... adaptation rails required diamentor chambers page 87 diasoft software page 88 ...

® built-in solutions diamentor® chambers compact dose area product systems for ... or two measuring channels all-in-one chambers and electronic systems with or without ... with the requirements of iec 60580 flat ionization chambers for diamentor patient ... not interfere with routine work as the chambers are transparent and mounted directly to ... transparent and rectangular diamentor chambers size b are suitable for firm mounting ... rails moreover many different ionization chambers are available the chambers are ... room of the x-ray installation the chambers show a very low filter absorption and ... beam hardening effect the large chambers are designed for a maximum beam size of ... rails p rail distance 170 mm more chambers and adaptation rails upon request ... request please contact us diamentor chambers page 87 diamentor accessories page 88 ...
available can be screwed easily to the ionization chamber distance adaptation rails ...
class dosemeter unidos e connecting ionization chambers and the multipurpose ...
and a it can be used with a variety of ionization chambers and solid state detectors a ct ... option unitest electric test device sfd chambers page 96 diagnostic measuring phantom ...
absolute dosimetry equipment sfd chambers for diagnostic x-rays flat chamber for ... diagnostic x-rays shadow free ionization chambers 6 cm3 and 75 cm3 for absolute ... dosimetry features plane parallel chambers for the measurement and monitoring of ... range 25 35 kv both flat sfd chambers are used for dose and dose rate ... construction and low attenuation both chambers give near to no interference with the ... with the hvl measuring stand both chambers comply fully with iec 61674 the cable ... length is 2.5 m each flat ionization chamber 30 cm3 for precise dose ... e page 95 ordering information sfd chambers connecting system bnt tnc or m 34069-2, ...
iec 61145 calibration and usage of ionization chamber systems for assay of ...
curiementor 4 radioactive check device ionization chamber lead shielding curiementor ...
bq ci or in a the pressurized well-type ionization chamber has nearly 4 measuring geometry ...
4 isotope calibrator includes a well ionization chamber with argon gas filling at 1,5 ... calibrator consists of a t33007 pet ionization chamber and a curiementor 4 display ...
nuclear medicine isotope calibrators ionization chamber lead shielding curiementor® ... radiation shielding of the curiementor ionization chamber features makes it possible to ... the separation of the curiementor ionization chamber and the display unit makes it ...
emitting units stationary monitors ionization chambers of various volumes to monitor ... calibration various high quality ion chambers are available for precise calibration ...
is based on a 600 cm3 large volume ionization chamber which provides high precision ...
radiation monitoring equipment 3 liter chambers for 50 liter chamber for radiation ... monitoring cylindrical polyethylene ionization chambers for stationary radiation ... liters suitable as radiation monitoring chambers gamma energy range 80 kev to 1.3 mev ... the 3 liter chambers are used as stationary surveillance ... environmental radiation monitoring the chambers are designed to measure protection ... rate at 90 saturation is 10 sv/h the chambers are fully guarded up to the measuring ... for precise measurement the cylindrical chambers are made of graphite coated ... signal and the polarizing voltage the chambers are supplied with two coaxial ... system cylindrical pressurized steel ionization chamber for stationary gamma radiation ... energy range 80 kev to 1.3 mev the ionization chamber t7262 has a constructive volume ...

across the measuring volume of the ionization chamber connected the unidos models ... are high precision dosemeters utilizing ionization chambers for radiation protection dose ...

extension to connect up to 18 xls ionization chambers the system measures dose and ... rate or charge and current of all 18 chambers simultaneously the maximum and minimum ... base unit the measuring results of all chambers can be read via an rs232 interface the ... diagnostic x-ray equipment rectangular ionization chamber for radiation leakage ... of x-ray leakage radiation up to 18 chambers can be arranged for radiation leakage ... the rectangular plane parallel xls ionization chamber is used for the xls x-ray ... range is from 0.4 pa to 100 pa up to 18 chambers can be mechanically arranged on a ... parts are neither part of the xls chambers nor the xls x-ray leakage system the ... and the long-term stability of the chambers can be checked by means of an ... type t48010 or t8921/8922 and the chambers type ta34055-0 ordering information ...

wheel for x-ray calibration monitor ionization chambers x-ray therapy monitor ... ionization chamber cylinder stem ionization chamber tk-30 spherical ionization ... chamber 1 liter spherical ionization chamber 10 liter spherical ionization ...
as well as a variety of reference ionization chambers for calibration purposes ...
calibration equipment monitor ionization chambers x-ray therapy monitor ... ionization chamber large size plane parallel ... transmission chambers for use as dose monitors combined with ... volumes shadow-free transmission chambers for dose monitoring with calibration ... circular plane parallel transmission chambers are used for dose monitoring in ... sensitive volumes are designed as twin-chambers with 2.5 mm measuring depth each and a ... leakage current is less than 1 pa the chambers are fully guarded the external diameter ... connector and banana pin option monitor chambers with smaller diameter of sensitive ...
calibration equipment cylinder stem ionization chamber tk-30 spherical ionization ... chamber cylindrical pmma ionization chamber with a long rigid stem for ... holding device are available spherical ionization chamber with a long rigid stem for ...
calibration equipment 1 liter spherical ionization chamber 10 liter spherical ionization ... chamber spherical ionization chamber for radiation protection level ... dimensions to protect them spherical ionization chamber for radiation protection level ...
the dose is determined from the ionization density in a small air gap the ...
soft x-ray chamber parallel plate ionization chamber for direct measurement of hp10 ... for hp10 calibration the parallel plate ionization chamber model 340351 is integrated into ... techn publishing acrylic parallel plate ionization chamber for reference dosimetry with ... window the circular parallel plate ionization chamber model 340471 is intended as a ...
x-rays 10 70 kv in addition well-type chambers can be calibrated to measure ... for the calibration of dosemeters ct-chambers and dap meters in different ranges from ... protection and diagnostic dosimeters ct-chambers and dap meters in different ranges from ...
sources measured by well-type chambers diagnostic x-ray generator high ...
photons bnt tnc or m connector thimble ionization chambers 31010 semiflex 0.125 cm3 ion ... bnt tnc or m connector plane parallel ionization chambers 34045 advanced markus 0.02 cm3 ... 19 page 16-18 page 21 liquid filled ionization chamber 31018 microlion chamber 0.002 ...
various applications especially the ion chambers designed for absolute dosimetry in ... be used for therapy beam analysis all ionization chambers are supplied with vented ... m connector 10.5 cm3 2.5 cm3 bragg peak chambers 0.005 cm3 soft x-ray chamber 0.02 cm3 ... x-ray chamber waterproof plane parallel chambers for measuring the exact location of the ...
x-check flu x-check pro x-check rad xls ionization chamber x-ray leakage system x-ray test ...