92 results for measure devices found in 0.000 seconds

Radiation Medicine QA Solutions 2008/2009 by PTW

Catalog: Radiation Medicine QA Solutions 2008/2009
Company/Brand: PTW



measure devices in Radiation Medicine QA Solutions 2008/2009 by PTW


 
Show page 2
supplying specialized dosemeters to measure the quantity of ionizing radiation with ... operation to provide for correct measurement of radiation quantities by the ... equipment and radiation monitoring devices have always been part of the ptw ... the use of a computer electronic devices are microprocessor controlled and may ...
 
Show page 12
chambers solid state detectors check devices and calibration phantoms in different ... at the dosemeter and to perform dose measurements by remote control the measurement data ...
 
Show page 13
or by means of radioactive check devices the check device data are stored in a ...
 
Show page 14
linearity reproducibility and stability measures integrated dose or charge and dose rate ... in-vivo dosemeter for patient contact measurement according to iec 60601-2-9 an x-ray ... or by means of radioactive check devices unidos displays the measured values of ... 0 ± 400 v in increments of ± 50 v measures integrated dose or charge and dose rate ... and temperature unidos e displays the measured values of dose and dose rate in gy r gy ... values charge and current are measured in c and a the large high-contrast lc ...
 
Show page 15
class resolution 10 fa absolute dose measurement with tansoft software fast scanning ... measurements in motorized water phantoms time ... for various detectors and displays the measurement results the chamber voltage for both ... designed to perform radiation field measurements referenced to an ionization chamber in ... a trigger input synchronizes measurements with external signals brachytherapy ... and 32p calibration traceable to nist2 measures dose dose rate and time the optidos3 is ...
 
Show page 16
dosimetry mainly for dose distribution measurements in motorized water phantoms they have a ... an acrylic build-up cap for inair measurement in 60co beams is included with each ... density correction is required for each measurement and a radioactive check device is ... beam an acrylic build-up cap for in-air measurement in 60co beams is included with each ... density correction is required for each measurement a radioactive check device is available ... pages 13 to 15 radioactive check devices page 23 calibration service page 166 ... pages 13 to 15 radioactive check devices page 23 calibration service page 166 16 ...
 
Show page 17
dosemeters three chamber types for measurements in air or in solid state phantom ... an acrylic build-up cap for in-air measurement in 60co beams is included with each ... density correction is required for each measurement a radioactive check device is available ... pages 13 to 15 radioactive check devices page 23 calibration service page 166 ... pages 13 to 15 radioactive check devices page 23 calibration service page 166 17 ...
 
Show page 18
cm3 suitable for intracavitary in-vivo measurements in conjunction with an unidos dosemeter ... the chambers are ideal for in-vivo measurements during gynecological afterloading ... type 23322 is used with a catheter for measurements in the bladder whereas chamber type ... 23323 is designed for measurements in the rectum using a protective sleeve ... waterproof ion chambers for dose measurements in radiotherapy with high spatial ... designed for relative beam profile measurements in a motorized water phantom for ... used for depth dose and absolute dose measurements the sensitive volume is vented the wall ... cables page 29 tba detector holding devices page 48 ordering information sealed ... pages 13 to 15 radioactive check devices page 23 calibration service page 166 18 ...
 
Show page 19
diode detectors for dose distribution measurements in high-energy photon and electron ... designed for dose distribution measurements in high-energy photon and electron ... for high precision dose distribution measurements since the dosimetry diodes are ... waterproof diamond detector for dose measurements in high-energy photon and electron ... it is designed for dose distribution measurements in highenergy photon and electron beams ... cables page 29 tba detector holding devices page 48 ordering information tm60003 ... cables page 29 tba detector holding devices page 48 19 ...
 
Show page 21
ion chamber for highenergy electron measurements in water and solid state phantoms ... the chamber ideal for dose distribution measurements in a water phantom giving a good ... density correction is required for each measurement a radioactive check device is available ... for absolute dose and depth dose measurements in a water phantom the acrylic entrance ... density correction is required for each measurement a radioactive check device with adapter ... pages 13 to 15 radioactive check devices page 23 calibration service page 166 ... pages 13 to 15 radioactive check devices page 23 calibration service page 166 21 ...
 
Show page 22
thin flat entrance windows for dose measurements of low energy x-ray beams suitable for ... standard ionization chamber for dose measurements in superficial radiation therapy the 0. ... volume and makes it possible to measure therapeutic x-ray beams with very small ... density correction is required for each measurement a radioactive check device is available ... to perform absolute dose and depth dose measurement in a solid state phantom supplied with ... it is used for depth dose measurements and for calibration purposes using the ... storage case which is also used for the measurement set-up ordering information l981035 ... pages 13 to 15 radioactive check devices page 23 calibration service page 166 ...
 
Show page 23
dosimetry equipment radioactive check devices unisoft dosimetry software radioactive ... check devices for air density correction and ... 90sr type t48010 the radioactive check devices are recommended for high precision ... done each time before starting a dose measurement the chamber calibration certificate ... -value time is 28.7 years both check devices include shielding containers and the ... device temperature various holding devices for the adaptation of different ion ... pages 16 to 21 radioactive check devices page 23 mephysto mc2 software page 52 ... chambers chamber/check source holding devices upon request ionization chambers pages ...
 
Show page 26
type 4322 is designed for calibration measurements in radiation therapy using a horizontal ... and the size of 150 mm x 150 mm holding devices on the top and on the bottom of the ... type 41023 is designed for calibration measurements in radiation therapy using a horizontal ...
 
Show page 29
are of high quality for precise current measurements down to 10-15 a when irradiated the ... features the barometers provide precise measurement of absolute air pressure in hpa ...
 
Show page 34
for absolute dosimetry in-vivo measurements and quality control in radiation ... channel in-vivo dosemeter for diode measurements connection box required six channel in- ... vivo dosemeter for diode measurements in rectum and bladder connection box ... -2-9 as a dosemeter for patient contact measures dose and dose rate or charge and ... with linear accelerators features measure patient dose during external ... are fixed to the patient s body to measure the patient skin entrance or exit dose ... 60co to 25 mv and one type for electron measurements are available the detectors do not ...
 
Show page 35
high-energy photon and electron dose measurement see page 34 the maximum cable length ... two rollers are equipped with locking devices the system is designed for robust daily ... high-energy photon and electron dose measurement see page 34 the maximum cable length ...
 
Show page 38
for afterloading source strength measurements features vented sensitive volume of 200 ... cm3 makes it possible to measure the source strength of afterloading ... is required for the source strength measurement of radioactive afterloading sources the ... to nist usa and ptb germany for measurements the chamber is connected to a sensitive ... -2-9 as a dosemeter for patient contact measures integrated dose and dose rate ... it is designed for dose and dose rate measurements inside the rectum and the bladder ...
 
Show page 39
brachytherapy sources features measures the source strength with 4 geometry ... for high precision source strength measurements an acrylic guide tube of 3.6 mm inner ... the radioactive source to be measured the sourcecheck chamber makes it ... possible to measure single seeds or seed trains of up to ... type bnt or tnc or ptw-m is mounted for measurements the sourcecheck chamber is connected to ... to use sourcecheck for source strength measurement in various brachytherapy applications ... adapters for single seed or strands measurement adapters to connect afterloaders for ... hdr brachytherapy adapters for the measurement of sources for intravascular ... applications an adapter for single seed measurement can be loaded manually with a single ... by using the appropriate adapter to measure the entire strand in one run this ...
 
Show page 40
and 32p calibration traceable to nist2 measures dose dose rate and time the optidos3 is ... are also intended for dose distribution measurement of brachytherapy sources by measuring ...
 
Show page 41
positioning tba detector holding devices tba scanning detectors la48 linear ... array tpr options tba positioning devices scan lift lifting/reservoir carriage ... for film densitometry me48f fast measurement system peakfinder water column 43 43 44 ...
 
Show page 42
therapy beam analysis dose distribution measurements and analyses of radiotherapy beams are ... in combination with common electronic devices and software and a variety of ... radiation detectors enable the user to measure easily and accurately pulsed photon ... ideally suited to perform all of the measurement tasks of a physics department in ... treatment units after installation measurements after repair or replacement of major ... the systems can easily perform measurements at any point along any vector or in any ... electrometer performs integrated dose measurements within 10 ms and the high precision ... phantom positioning and water reservoir devices air scanners for table top placement or ...
 
Show page 43
phantom for automatic dose distribution measurement of radiation therapy beams features ... tank is suitable for very large field measurements beam incidence may be vertical ... they do not disturb or affect the measurement accuracy the tank is supplied with a ... for automatic dose distribution measurement of radiation therapy beams features ... .5 mm is suitable for dose distribution measurements of standard field sizes in radiation ... they do not disturb or affect the measurement accuracy the tank is supplied with a ...
 
Show page 44
phantom for automatic dose distribution measurement at tomotherapy® treatment units ... horizontal beams with highest precision measurements dual chamber holders allow the fixation ... the moving mechanism for relative dose measurements to operate the tank mephysto mc2 ... as reference and chamber type 34070 measures depth dose distributions mp3-p ...
 
Show page 45
phantom for automatic dose distribution measurement of radiation therapy beams features ... stereotactic or iort dose distribution measurements 3d stainless steel moving mechanism ... for remote-controlled dose distribution measurements of small radiation fields as used for ... they do not disturb or affect the measurement accuracy the delivery includes a cable ... phantom for automatic dose distribution measurement of radiation therapy beams features ... for twodimensional dose distribution measurements includes a sturdy 2d stainless steel ... device rotates the mp2 tank for measurement of both principle axes and the ... diagonals detector holding devices are optionally available beam ...
 
Show page 46
phantoms for absolute dosimetry and measurement of depth dose curves features high ... for absolute dosimetry and depth dose measurement of high energy photon and electron ... are small 1d phantoms for depth dose measurement to determine beam qualities and measure ... -m and 225 mm x 275 mm mp1-s holding devices to mount semiflex farmer and electron ... acrylic phantom for dose distribution measurements in a solid state phantom features makes ... it possible to measure profiles and depth dose curves in a ... s unique design makes it possible to measure continuous profiles and depth dose ... beam axis as well as for off-axis measurement within an area of 122 mm in diameter a ... to enter the treatment room after each measurement while the cumbersome setup of a remote ... -m manual phantom tank chamber holding devices upon request unisoft edition 2000 page ...
 
Show page 47
class resolution 10 fa absolute dose measurement with tansoft software fast scanning ... measurements in motorized water phantoms time ... for various detectors and displays the measurement results the chamber voltage for both ... designed to perform radiation field measurements referenced to an ionization chamber in ... a trigger input synchronizes measurements with external signals electronic ... devices for detector positioning by automatic ... phantom tanks and other tba scanning devices positioning commands from a computer ...
 
Show page 48
positions the effective point of measurement of different therapy detectors exactly ... positioning of effective points of measurement of detectors on the water surface ... resetting the effective points of measurement can also be used for horizontal ... positioning of effective points of measurement of various detectors on the water ... in radiotherapy dose distribution measurements the semiflex 0.125 cm3 ion chamber is ... both stereotactic and standard field measurements and provide a favorable signal-to-noise ... ratio dose distribution measurements of electron beams are performed by ... or percentage electron depth dose measurements are done with the roos chamber the ... bragg peak chamber is used for relativ measurements for determination of the depth dose ... distribution of linac light fields is measured with the light probe all detectors are ...
 
Show page 49
/me48 dosemeter for fast profile measurements features suitable for imrt and dynamic ... field measurements the latest development in fluid-filled ... and reliable dynamic field dosimetry measurements of virtual wedges and multileaf ... a software module to control the measurement store the data and evaluate the results ... is included for measurements in water the la48 array is mounted to ... tank by using the appropriate holding devices the la48 array may also be used as an ... air scanner options for automatic tpr measurement including water sensor and mephysto ... software module features measure tissue-phantom-ratio automatically ... used for the mp3 and mp3-m systems to measure tissue-phantom-ratios by keeping the ... mc2 software pages 52 and 53 me48f fast measurement system page 59 la48/sla48 air scanner ...
 
Show page 50
beam analysis equipment tba positioning devices scanlift lifting reservoir carriage ... rotatable devices for horizontal vertical and angular ... by ± 45° and ± 90° the positioning devices are used for geometric adjustments of ... tank and to lock it at ± 45° for the measurement of diagonals and ± 90° for inplane and ... crossplane measurements when using the mp2 phantom tank or the ... 43 tpr options page 49 tba positioning devices page 50 ordering information t4316/u182 ...
 
Show page 51
time as expected with hydraulic lifting devices large castors make the carriage easy to ... manually or by pc control for tpr measurements two compartments to store dosimetry ... phantom tank page 43 tba positioning devices page 50 ordering information t43163- ...
 
Show page 52
physics control center predefined measurement programs for pdds profiles matrices for ... software or documents can be integrated measurements with self explaining graphical ... with two tabs for accelerator and measurement parameters the user can quickly and ... easily start a measurement linac commissioning and tps beam data ...
 
Show page 53
dynamic imrt fields and wedges can be measured and analyzed tpr allows easy and ... precise tpr measurements with an optimized module with stepping ... dosimetry tansoft for absolute dose measurement with tandem electrometer in accordance ...
 
Show page 55
1d moving mechanism for single detector measurement features makes one-dimensional in-air ... scanning possible for dose distribution measurements by control of tba components includes a ... steel moving mechanism for profile measurements using a small volume radiation detector ... accelerator and makes it possible to measure profiles under arbitrary gantry angles ... holding devices for different accelerator types are ... available x and y profiles can be measured by 90° manual rotation of the device ... 1d moving mechanism for single detector measurement features makes one-dimensional in-air ... scanning possible for dose distribution measurements by control of tba components includes a ... steel moving mechanism for profile measurements using a small volume radiation detector ... the table-top of the treatment couch to measure at vertical beam incidence ordering ...
 
Show page 56
the la48 linear array for fast profile measurements of dynamic and conventional fields ... two acrylic build-up plates for profile measurements at different depths the air scanner ... of a linear accelerator for profile measurements free in air with a spatial resolution ... into the rails by 90° rotation to measure inplane and crossplane profiles the ... fixed to the accelerator gantry profile measurements can be done at different gantry angles ... two acrylic build-up plates for profile measurements at depths of 10 mm and 25 mm are ... the la48 linear array for fast profile measurements of dynamic and conventional fields can ... two acrylic build-up plates for profile measurements at different depths the air scanner ... -top of a treatment couch for profile measurements free in air with a spatial resolution ...
 
Show page 57
moving mechanism for dose distribution measurement using the la48 array features ... to 100 mm acrylic build-up material for measurements at different depths the sla48 air ... the device is used for one-dimensional measurements of inplane/crossplane profiles and of ... also used for routine quality-control measurements photon beams as well as electron beams ... the user to verify the location of the measured dose distribution with respect to the ... laser alignment for 2d measurements two precision stepper motors move the ... moving mechanism for dose distribution measurement using the la48 array features ... to 100 mm acrylic build-up material for measurements in different depths the air scanner ... of a treatment couch for onedimensional measurements of inplane/crossplane profiles and of ... also used for routine quality-control measurements the maximum field size is 400 mm x 400 ...
 
Show page 62
unit operation time the quality test devices enable the responsible medical physics ...
 
Show page 63
time in daily routines the david measurement system makes it possible for the first ... chamber mic is installed below the mlcs measurement wires are stretched parallel to the ... running direction of the mlcs each measurement wire monitors the opening of a leaf ... pair the measured dose length product is correlated to ... evaluation software compares the dose measured during radiotherapy to a reference dose ... for each leaf pair during a reference measurement david can be used independent of the ... or dynamic arc chamber the david measurement chamber is a transparent segmented ... multiwire ionization chamber mic measurement wires are stretched parallel in the ... chamber each chamber wire measures the dose resulting from the opening of ... a battery supplies power to the measurement system the battery offers an operating ...
 
Show page 64
software chamber matrix system to measure high resolution star profiles of high- ... therapy beams in real-time features measures high resolution profiles along the ... diagonals with 3 mm spatial resolution measures congruence between light field and ... is a precise and reliable tool for fast measurements in radiation therapy beams typical ... control and linac beam adjustment measurements with the detector panel embedded in a ... a full set of four profiles is measured every 200 ms making the device useful ... for real-time measurements the excellent spatial resolution of ... only 3 mm ensures precise measurements even in penumbra regions the scanning ... the position of the radiation field is measured and compared with the expected ideal ...
 
Show page 65
radiation therapy quality control equipment 2d-array seven29 27 x 27 ion chamber array for precise imrt plan verification and linac qa features 27 x 27 729 vented cubic ionization chambers regularly arranged to mlc leafs across the complete field size of 27 cm x 27 cm avoids detector ageing effects by utilizing ion chambers no radiation damage thanks to separated evaluation electronics 5 year warranty complete field coverage with merge seven29 the 2d-array seven29 is a new concept of an ion chamber matrix in a plane for imrt verification and quality control in radiation therapy utilizing ion chambers ...
 
Show page 68
mean deviation works on the basis of measurements performed with the la48 linear array ...
 
Show page 69
phantom and by comparing the measured phantom values and the calculated ... connected to integrating dosemeters measure absolute dose values the phantom ... this combination makes it possible to measure the imrt dose profile in the axis of ...
 
Show page 72
60976 requires only a dual chamber dose measurement mounts to the linac accessory tray ... by the 50 isodose usually an isodose measurement with an automatic 3d water phantom is ... wedgecheck1 only requires the measurement of two off-axis dose values either ... deliver a dose integral which can be measured by any therapy dosemeter the signal is ...
 
Show page 73
for highenergy photon and electron measurements stores and displays the measurement ... units and beam qualities take dose measurements from six built-in ion chambers of the ... measuring system and display the measurement information in different formats the ... -in temperature and pressure after each measurement the data is automatically saved to the ... energy stability data from previous measurement can be reviewed and edited as well as ... or daily report of the collected measurements ordering information l981083 qc6plus ...
 
Show page 75
results are compared with previous measurements under identical irradiation conditions ... in a simple and reliable manner measures dose dose rate and irradiation time ... ionization chamber stores up to 99 measurements communicates with a computer using the ... accelerator the monitor calibration for measurements the lightweight device is put on the ... reading from a distance as up to 99 measurements can be stored all linacs may be checked ... photon and electron energies when the measurements are finished data can be evaluated the ...
 
Show page 76
control of electronic portal imaging devices used in high-energy photon beams ... vertical and diagonal direction measurement of all parameters with a single beam in ... one image electronic portal imaging devices epid are used in radiation therapy to ... a complete quality control procedure measured in a single beam it checks linearity ...
 
Show page 77
any detector and phantom assembly for measurements in the isocenter universal tool for any ... chamber array can be fixed for profile measurements or a 2d chamber matrix can be attached ... for on-line measurements in a plane alternatively a radiographic ...
 
Show page 80
1994-03 constancy tests image display devices 1994-04 constancy tests x-ray ... instruments used for non-invasive measurement of x-ray tube voltage in diagnostic ...
 
Show page 82
the 21 cfr part 1020 federal register measures and protocols the dose area product dap ...
 
Show page 83
for patient entrance dose and dose rate measurement during diagnostic x-ray examinations ... use complies with fda 21cfr part 1020 measures kerma and kerma rate at a reference ... usa device for simultaneous measurements of dap dose and dose rate in ... unique design technology the unit can measure dose dose rate and dose area product ...
 
Show page 84
product meter the dual channel device measures the total diagnostic dose area product ... exposure time during fluoroscopy is measured without the need of any connection to ... channels enabling simultaneous measurements with two chambers the system can also ... channel can be reset separately and the measured values of channel a and b can be ...
 
Show page 85
compact dosemeter for dap and dap rate measurement in patient dosimetry during diagnostic ... gym2/s and consequently is suitable for measurements in pediatric radiology ordering ...
 
Show page 86
the diamentor set ci is suitable for measurements in pediatric applications and fully ... µgym2 the diamentor cm is suitable for measurements in pediatric applications and fully ...
 
Show page 87
multifunctional and dual channel devices for single plane and biplane x-ray ... are available for presenting the measured dose area product or dose results the ... patient dosemeters features very simple measurement of patient exposures do not interfere ... ray collimator the combined kdk chamber measures dose area product and dose ...
 
Show page 93
dental x-ray and ct features measures dose dose rate dose per pulse dose ... product and irradiation time ideal for measurements in the useful x-ray beam at the ... 3 pa to 20 µa and charge 3 pc to 200 mc measurements complies with iec 61674 diados is an ... equipment using various accessories the measurements of radiographic fluoroscopic ... based on solid state detectors the ct measurement is based on a ct ion chamber connected ... dose dose per pulse and exposure time measurement starts as soon as the diados detects ... and service of any x-ray equipment measures dose dose rate dose per pulse pulses ... 3 pa to 20 µa and charge 3 pc to 200 mc measurement the diados e is a small size dosemeter ... of diagnostic x-ray installation which measures dose values and irradiation time it ... semiconductor detectors except for ct measurement which is based on a pencil ion chamber ...
 
Show page 94
with a radioactive check device or measurement of air pressure and temperature comply ... cable length is 2 m the detectors can measure the following quantities in conjunction ... dosimetry features makes it possible to measure doses of all types of dental intraoral ... units require different setup for dose measurements transmission doses from intraoral units ... remote x-ray units require the dose measurement behind an absorber of 6 mm al and 0.8 ... .3 mm cu and 8 mm ptfe can be used dose measurements of panoramic x-ray units with movable ... filter setting for this type of dose measurement is 6 mm al 0.5 mm cu for film-screen ... focus and detector dental doses are measured using the diados diagnostic detector ... t42018 absorber set for dental dose measurement t20003 dental cassette adapter l981234 ...
 
Show page 95
available the ct probe is inserted for measurements into one of five holes of the head or ... suited for acceptance tests and routine measurements in diagnostic radiology it measures ... a ct probe can be connected to measure the dose length product in gy·m for ...
 
Show page 96
plane parallel chambers for the measurement and monitoring of radiation output in ... do not influence the x-ray image for measurements in front of and behind a phantom the ... are used for dose and dose rate measurements in front and behind of a patient- ... shadows on the image furthermore hvl measurements can be performed conveniently using ... chamber 30 cm3 for precise dose measurements in the useful x-ray beam features ... enables dose measurements of diagnostic x-ray qualities in air ... is especially designed for x-ray dose measurements in air down to 35 kev radiation energy ...
 
Show page 99
stand slit camera cd lux meter light measurement test patterns x-ray image tests sensix ...
 
Show page 101
small size and lightweight measuring devices for non-invasive quality control of any ... x-ray equipment measure dose dose rate dose per pulse dose ... and the voltage parameters are measured by two separate and independent devices ... features software for fast and precise measurement analysis for use with all diavolt types ... software acquires and evaluates the measured values by means of an automatically ... tests can be determined based on dose measurements by using the diados e moreover ... and provides statistical evaluation measured data can be stored or exported to excel ... t42018 absorber set for dental dose measurement diados e page 93 diavolt qc meters ...
 
Show page 102
for kvp ppv1 dose and exposure time measurements at x-ray installations features compact ... of different x-ray installations measures kvp ppv1 dose and exposure time in one ... the diavolt universal is designed for measurements of kvpmean kvpmax ppv1 exposure time ... switches automatically when used for measurements on under couch tubes the diavolt ... of the fast sampling frequency precise measurements can be performed even on very demanding ... for kvp ppv dose and exposure time measurements at x-ray installations features compact ... except of mammography units measures kvp ppv dose and exposure time in one ... tubes the diavolt multi is designed for measurements of kvpmean kvpmax ppv exposure time and ... switches automatically when used for measurements on under couch tubes the diavolt multi ... of the fast sampling frequency precise measurements can be performed even on very demanding ...
 
Show page 103
for kvp ppv dose and exposure time measurements at x-ray installations features compact ... and fluoroscopic x-ray installations measures kvp ppv dose and exposure time in one ... the diavolt rad/flu is designed for measurements of kvpmean kvpmax ppv exposure time and ... switches automatically when used for measurements on under couch tubes the diavolt rad/ ... of the fast sampling frequency precise measurements can be performed even on very demanding ... for kvp ppv dose and exposure time measurements in mammography features compact non- ... of mammographic x-ray installations measures kvp ppv dose and exposure time in one ... tubes the diavolt mam is designed for measurements of kvpmean kvpmax ppv exposure time and ... switches automatically when used for measurements on under couch tubes the diavolt mam ...
 
Show page 104
small size dosemeter for routine qc measures the entrance dose and dose rate in ... constancy check should include a dose measurement the conny ii dosemeter is especially ... for qc of radiography and fluoroscopy devices and with the normi and x-check phantoms ... is 300 mm x 300 mm the entrance dose is measured with a diados or diados e dosemeter ...
 
Show page 106
suitable for health physics measurements by an optional scattering plate and a ... conny ii dosemeter for entrance dose measurements test object for constancy tests of ... field in the centre for optical density measurements all relevant parameters can be checked ... rails the entrance dose can be measured with a conny ii dosemeter ordering ... rex scattering plate for health physics measurements l653003 magnifying glass 8x conny ii ...
 
Show page 107
rails the entrance dose can be measured with a conny ii dosemeter test object ... and c arms the entrance dose can be measured with a conny ii or diados e dosemeter ...
 
Show page 108
diagnostic dosemeter for entrance dose measurement the normi 13 test object is designed ... test pattern an area for entrance dose measurement and homogeneous areas for homogeneity ... 300 mm x 300 mm the entrance dose is measured by the conny ii or the diados e ...
 
Show page 112
0-300 n ± 5 n displayed unit is kg it measures the compression force for all ... including the maximum value the measured values and the indicated values at the ...
 
Show page 114
spot measuring stand cd lux meter light measurement stand for focal spot measurements by ... or slit camera features focal spot measurements according to iec 60336 and nema xr5- ... of viewing boxes and image display devices features measures the luminance and ... of viewing boxes and image display devices includes a spacing tool for correct ... built-in laser pointer for precise measurements by indicating the measuring spot all ... parameters acc iec and din can be measured in combination with a test picture the ... regularly boxes and image display devices are tested easily by using the battery ... operated cd lux meter which measures the luminance in cd/m2 with the lux ... detector measurements of the room illuminance in lux can be ... in the surrounding of image display devices for continuous operation two leds ...
 
Show page 117
device for automatic and manual density measurements of x-ray films in the range 0.0 4.00 ... of film processing systems single-point measurement by a separate measuring arm with 18 cm ... of sensix test films up to five measurement results can be stored in the unit ... designed for automatic optical density measurements of 21-step wedges exposed by the sensix ...
 
Show page 118
films suitable for manual single point measurement of optical densities in the range 0.00 ... for optical density single point measurements of processed x-ray films exposed by a ... arm is 20 cm which makes it possible to measure the optical density even in the middle ... films suitable for manual single point measurement of optical densities in the range 0.00 ... for optical density single-point measurements of processed x-ray films exposed by a ... arm is 20 cm which makes it possible to measure the optical density even in the middle ... film transport and computer controlled measurement and evaluation of test films exposed by ...
 
Show page 119
`a diagnostic qc set `b set of test devices for quality control of x-ray film ... processing comprises all relevant test devices a sensix sensitometer a densix ... exposures to a test film set of test devices for quality control of film processing ... x-ray units comprises all relevant test devices a rex phantom a conny ii dosemeter a ...
 
Show page 126
nuclear medicine introduction radiation measurement and quality control in nuclear medicine ... patient s body and its emissions are measured by a pet scanner spect like pet ... international regulations radiation measurement and quality control procedures for ... test conditions of radionuclide imaging devices ­ anger type gamma camera iec 61145 ... iec 61675-1 radionuclide imaging devices ­ characteristics and test conditions ... iec 61675-2 radionuclide imaging devices ­ characteristics and test conditions ... iec 61675-3 radionuclide imaging devices ­ characteristics and test conditions ... publication nu2-2001 performance measurements of positron emission tomographs cec ...
 
Show page 129
calibrator for radionuclide activity measurement in nuclear medicine and intravascular ... 3 isotope calibrator enables users to measure activity of radioactive isotopes as ... calibrator for radionuclide activity measurement in nuclear medicine and intravascular ... sophisticated instrument for activity measurements in nuclear medicine including pet it ... to 92 gbq for pet applications can be measured up to 140 measuring results including ...
 
Show page 130
isotope calibrator for high activity measurement in pet nuclide production features ... measures high activities in pet nuclide ... calibrator suited for high activity measurement the pet curiementor 4 isotope ... is from 0.1 mbq to 350 gbq the system measures and displays the activity of nuclides ... is calibrated for high activity measurement the use of the curiementor 3 or ... recommended for low and medium activity measurements check source for curiementor ...
 
Show page 139
for quality control of uptake measuring devices features simulates the thyroid with ... proper performance of uptake measuring devices by simulating a thyroid in its anatomic ... cylinder accommodates two inserts to measure the initial pulse rate of radioactive ...
 
Show page 147
for radioactive contamination measurement of surfaces in nuclear medicine ... detector gas filling or gas flow measures alpha beta and gamma radiation using ... contamination monitor model como 170 measures alpha beta and gamma contamination with ... function with adjustable background measurement time is included the measuring results ... largearea graphical lc display the measurement is menuprompted and the measuring data ... barrier that activates the start of measurements the active wall mount comes with an ...
 
Show page 148
dosemeter for dose and dose rate measurements of x and gamma radiation features ... 2 2000 µsv dose rate 2 µsv/h 2msv/h measures continuous and pulsed radiation the ... and a wide range of health physics measurements the wall reinforcement cap can be ... removed for low energy measurements down to 6 kev the unit is prepared for ... based upon modern detector technology measure the radiation quantities hp10 and hp0. ... for personal radiation protection measurements the nominal useful energy range for ...
 
Show page 151
protection finger rings for tld measurement of ionizing radiation exposure to hands ... features measure the radiation load to hands of persons ... may result in high exposure values the measurement of the radiation load to their hands is ... readers from various suppliers features measure the personal doses from thermal neutron ... plastic capsules make it possible to measure the thermal neutron backscatter from ... in the albedo dosimetry cases for measurement and then read out by an automatic tld ...
 
Show page 153
are used as stationary surveillance devices for environmental radiation monitoring ... the chambers are designed to measure protection level dose rates the ... correction is required for precise measurement the cylindrical chambers are made of ... performing low level gamma radiation measurements down to the natural radiation ...
 
Show page 154
for simultaneous dose and dose rate measurement high accuracy excellent resolution 1fa ... chambers for radiation protection dose measurements a built-in relay can automatically be ... 400v in increments of ± 50 v the unit measures integrated dose or dose rate ... hp10 the ambient equivalent dose both measured in sievert sv the unidos can also be ... for simultaneous dose and dose rate measurement integration in a lan with the internet ... or by means of radioactive check devices the check device data are stored in a ...
 
Show page 155
channel dosemeter for radiation leakage measurements of diagnostic x-ray installations ... features measures dose and dose rate at 18 locations ... 18 xls ionization chambers the system measures dose and dose rate or charge and ... integration time for dose and charge measurements can be selected between 1 second and 18 ... chamber for radiation leakage measurements of diagnostic x-ray installations ... chamber connected to the xls electronic devices is from 0.15 mgy/h to 30 mgy/h and the ... system page 155 radioactive check devices page 23 155 ...
 
Show page 159
dosemeters used for ionizing radiation measurement features positions radiation detectors ... part of the calibration bench optional devices for manual vertical and horizontal ...
 
Show page 162
rigid stem for radiation protection measurement features vented sensitive volume of 30 ... cap with 3 mm wall thickness for in-air measurement in 60co beams is included with each ... density correction is required for each measurement a radioactive check device and an ... rigid stem for radiation protection measurement features vented sensitive volume of 28 ... density correction is required for each measurement ordering information tn32005 tk-30 ...
 
Show page 163
protection level and low level measurement features vented sensitive volume of 1 ... survey meter calibration and low level measurements superior energy response ... chamber model 32002 is designed for the measurement of ionizing radiation in the protection ... protection level and low level measurement features vented sensitive volume of 10 ... survey meter calibration and low level measurements superior energy response ...
 
Show page 164
with adjustable volume depth for measurement of absorbed dose in soft tissue ... features measures absolute dose of beta radiation and ... a high quality device for absorbed dose measurements of beta and low energy x radiation in ... of personal dosemeters because they measure the quantities hp0.07 and hp10 the iso ... type tests of personal dosemeters that measure the dose quantities hp0.07 and hp10 ... of area and personal dosemeters and the measurement of their response as a function of ...
 
Show page 165
plate ionization chamber for direct measurement of hp10 personal dose equivalent on a ... vented sensitive volume of 10 cm3 measures the hp10 personal dose equivalent ... is integrated into a slab phantom to measure the hp10 radiation protection measuring ... as a reference standard chamber for measurement of very low energy x-rays includes a ... as a reference standard chamber for the measurement of very low energy x-rays free in air ... class dosemeters for calibration measurements the response is 5 · 10-6 c/gy the ... the chamber in the radiation beam for measurement can be done by means of an adjustable ...
 
Show page 167
and check reading of radioactive check devices for atmospheric standard conditions ... provide the reference for the units of measurement according to the international system ... available absorbed energy to water dw measured in gray gy air kerma ka measured in ... hx and ambient equivalent dose h 10 measured in sievert sv exposure js measured in ... 1997 expression of the uncertainty of measurement in calibration a variety of ionizing ... cgym2h-1 of brachytherapy sources measured by well-type chambers diagnostic x-ray ... voltage of all types of x-ray equipment measured non-invasively by kv-meters different ... nuclide activity in nuclear medicine measured by isotope calibrators only curiementor ... quantities charge c and current a measured by highly sensitive electrometers ... every two years detectors and check devices pages 16 to 23 general information ...
 
Show page 170
the tasks and needs of users for the measurement of ionizing radiation and the quality ... with different detectors for the measurement of ionizing radiation of varying ... different radiation detectors for the measurement of the entire range of ionizing ... since the majority of electronic devices for the measurement of ionizing ...
 
Show page 175
entrance dose and dose rate page measurement during diagnostic x-ray examinations ... -kdk patient dosemeter for simultaneous measurement of patient entrance dose and dose rate ... for dose area product dap and dap rate measurement in patient dosimetry during diagnostic ...
 
Show page 177
well-type chamber for source strength measurement of afterloading sources bnt tnc or m ... flat chamber for source strength measurement of radioactive interstitial therapy ... ion chamber matrix system to measure high resolution star profiles of high- ...
 
Show page 181
and storing the data in tiff format measurement and analysis of the bragg peak with the ... quality control s070016 david software measurement evaluation and documentation of imrt ... page 75 s070013 me48f-soft fast profile measurements with the me48f electronic unit and page ... control of electronic portal imaging devices epid using the epid qc phantom page 76 ...
 
Show page 184
cassette adapter detector holding devices diacontrol expert software diadem ... chamber f farmer chamber fast measurement system film badge film digitizer film ...
 
Show page 185
product index product index product mic micro chamber microlion chamber mini phantom mlcsoft software moderator sphere monicheck monitor chamber mp1 phantom tank mp1-m manual phantom tank mp1-s phantom tank mp2 phantom tank mp3 phantom tank mp3-m phantom tank mp3-p phantom tank mp3-t phantom tank mp3-xs phantom tank multicheck software multidos for xls multidos ls18 multidos multi channel dosemeter multisoft software n normi 13 normi 3 normi 3/4 normi 4 normi 4 flu normi 58 normi mam normi pas o octavius optidos measuring phantom optidos scintillation detector optidos scintillation dosemeter oscilloscope ...
 
 
  Similar searches   moisture measure devices (36)
humidity measure devices (86)
soil moisture measure devices (7)
standard measuring devices (461)
watts measuring device (56)
diameter measuring devices (154)
platinum measurement electrodes (22)
tape measure (553)
natural gas measurement equip (38)
lightning device (71)
lightning device support (15)
profound loss hearing device (6)
laser measuring tools (89)
talking tape measure (21)
powder measures (281)
lifting devices (296)
vw wheels measure (10)
bearing measurment instruments (45)
390 ford measurements (56)
forster powder measure (6)
anti roll device (16)
measuring bullet caliber (42)
residual current device (18)
measures rings piston (159)
tip n measure containers (19)
measuring cups (292)
security watch devices (18)
metric tape measure (49)
residual current devices (18)
sign tape measure (23)
measuring camshaft lift (92)
427 ford measurements (34)
flow control devices (470)
electrical sensors device (149)
sensors device (493)
firearm safety devices (29)
main bearing sts measurments (8)
fitting measuring tool (718)
light weight lifting devices (29)
assembly lifting devices (69)
cartridge case measuring (77)
measuring ccs (194)
container lifting devices (34)
measure piston rings (159)
measuring tape (553)
corner measurements (295)
measuring shotgun chokes (6)
battery lift device (20)
auto body measuring (152)
distance measur laser (28)
fork oil measurements (59)
platinum measurement electrodes and ... (6)
device server (606)
water proof measuring tape (17)
laser speed measuring tools (18)
left hand tape measure (22)
double sided tape measure (52)
metric measuring tape (49)
plumbing devices (70)
tape measures (553)
digital tape measure (80)
data frame measure (88)
master house measurement (47)



Home | Latest catalogs | Contact

© 2006-2009 by who-sells-it.com