20 20G Tower Economy Home TV Tower 20G and 20G7 tower sections are constructed ... bracing electrically welded throughout, and built on a 12-1/2 equilateral ... . ROHN 25G accessories fit the 20G and 20G7 tower. The #20 tower is not ... or guyed at all times. Note: The price on #20 sections will be higher on ... , Nevada, oregon, Utah, Washington, and Wyoming. Sheet D-2751 (Replaces D-2361 ... ) 1 Refer to alphabetical/numerical price list for current prices. F.O.B. Peoria ... Illinois. Specifications subject to change without notice. H H H ...

D-2887 (Replaces D-2535) Note: The price on #45 and #5545G sections will be ... , Nevada, Oregon, Utah, Washington, and Wyoming. D Available by special order ... . Refer to alphabetical/numerical price list for current prices. F.O.B. Peoria ... , Illinois Specifications subject to change without notice. 45G ... is 1-1/4 galv. pipe, threaded on top and projecting 60 12 above apex of side ... . Mast support tube is 2-3/4 O.D. and 2-9/16 I.D. tubing, 18 total length. 60 ... 20 adapter section for joining 45G and 55G sections 160 45JBK Joint bolt kit 3 ...

consideration. Do not install towers and masts near power lines. All towers or ... towers. All towers should be installed and dismantled by experienced and trained ... inspected by qualified personnel and re-marked with hazard and warning ... at least twice a year to insure safety and proper performance. All antenna ... must be grounded per local and national codes. The mixing of so-called ... copies of ROHN products is dangerous and voids all data supplied by ROHN. ... -called copies are not the same quality and have not been tested or engineered by ... endanger the lives of your customers and cause serious tower failure and ... financial misfortune for all connected. Prices available on request. Specifications ... 4-1/2 CP4A Cap plates (set of 3 w/nuts and bolts) 15 APL4HA Beacon plate (leg ...

-2530 (Replaces D-2445) REFERENCE SHEET AND ASSEMBLY INFORMATION BRACKETOWERS, NON- ... a tower location sufficiently clear and out of falling distance of power lines ... since every electrical and telephone wire should be considered ... least twice the height of tower, mast and antenna combined. Tower should be ... installed and dismantled by experienced and trained personnel. All antenna ... 10 section should be leveled, plumbed, and temporarily guyed or braced while ... . Check tower to assure it is plumb and level after pouring concrete. Do not ... tower up into the concrete to level it and do not drive it hard into ground as ... this plugs leg holes and prevents moisture drainage. Crown the ... specific information on tower heights and placement of house brackets on #45 ... : Installation is greatly hastened and simplified by the use of an erection ...

2500 APL6A Beacon plate (leg mounted) and two cap plates w/nuts 16 and bolts ( ... for sections 83P, 83PH, 84, 84H and 85H) APL1258UM Mid beacon plate for ... 30 CP6A Cap plates (set of 3 w/nuts and bolts) for sections 15 83P, 83PH, 84, ... 84H, and 85H S80 Step bolts, one leg 1/ft. ... time for fabrication. See Hardware and Accessories section of the ROHN catalog ... the #80 tower. F.O.B. Peoria, Illinois Prices and Specifications subject to change ...
rotates to any direction on the mast, and with five guy holes, allows guying in ... 18 ga. 20 ga. 2-1/4 1-1/4 39 Details Specifications Last two digits in the part number ... be bracketed or guyed. Brackets, guys and base are not included and should be ... apart. Do not extend mast horizontally and then rotate up from hinged base. ... ham, CB or beam antennas. Refer to ROHN Price List for current prices. See ROHN ...

6 RPH1P Photocontrol Complete w/Socket and Outdoor Housing (120 Volt) 4 RPH2P ... Photocontrol Complete w/Socket and Outdoor Housing (230 Volt) 4 FA1SSX1 ... Lighting Control with Outdoor Housing and Photocontrol, Red Only (For Use with ... Lighting Control with Outdoor Housing and Photocontrol, Red Only (For Use with ... Lighting Control with Outdoor Housing and Photocontrol, Red Only (For Use with ... Lighting Control with Indoor Housing and Photocontrol, Red Only or Dual Lighting ... Lighting Control with Indoor Housing and Photocontrol, Red Only or Dual Lighting ... Lighting Control with Indoor Housing and Photocontrol, Red Only or Dual Lighting ... Lighting Control with Indoor Housing and Photocontrol, Red Only or Dual Lighting ... (For Use with Three Red 42 Beacons and Two Levels of Side Lights Open or Close ...

wire, fittings, junction boxes, lights, and flasher (where required) in outdoor ... with remote photocell. See drawings and parts lists for details. Notes: 1) ... FAA Advisory Circular 70/7460-1J. 2) Prices for special lighting kits including ... intensity strobes, dual lighting (red and strobes), and towers over 700' are ... . 3) Lamp life on 230 volt kits (RA1EE and RA1CE) is very short. * In addition to ... with a face width exceeding 41", up to and including 8' face width.) The material ... for additional information.) TL-2 377 Prices and specifications are subject to ...
Complete Control w/Outdoor Housing and Photocell A5LCANEMA4 Complete Control w ... /Outdoor Housing and Photocell REPLACEMENT PARTS FOR ... Note: Replacement Castings for B1 and B1R Beacons Available Upon Request * ... a complete unit Tower Lighting TL-3 378 Prices and specifications are subject to ...
listed, contact the factory. TL-4 379 Prices and specifications are subject to ...
' w/Exposed Wire 120 Volt AC TL-6 381 Prices and specifications are subject to ...
(530016) changes to #8 black (530009); and #12 red (530017) changes to #10 red ( ... 530014), and #14 black (530024) changes to #12 black ... towers, depending upon base size, and would consist of required material for ... 3/4" 2 TB27A TB Condulets, Gaskets, and Covers 3/4" 40 520002 Conduit Lock Nuts ... Flasher, Remote Photocell, Hardware, and Boost Transformers 3 B1R Beacons w/Red ... Unit) 351' to 700' w/Conduit TL-12 387 Prices and specifications are subject to ...
(530016) changes to #8 black (530009); and #12 red (530017) changes to #10 red ( ... 530014), and #14 black (530024) changes to #12 black ... towers, depending upon base size, and would consist of required material for ... 3/4" 2 TB27A TB Condulets, Gaskets, and Covers 3/4" 3 520031 Conduit Lock Nuts ... Unit) 351 to 700 w/Conduit TL-18 393 Prices and specifications are subject to ...

10 section should be leveled, plumbed and temporarily guyed or braced while ... . Check tower to assure it is plumb and level after pouring concrete. Do not ... tower up into the concrete to level it and do not drive it hard into ground as ... this plugs leg holes and prevents moisture drainage. Crown the ... ;fgk;fdsg;ldsg ;fdsg Height of Tower and Bracket Uses: See appropriate ROHN ... tightening U-Bolts.) Bolts: Nuts and bolts are located in tower legs on ROHN ... #20 and #25 towers. Installers are urged to use ... : Installation is greatly hastened and simplified with the use of an erection ... . If the antenna is to be fixed and a set screw used in the mast housing, ... only without antenna. When raising and lowering towie on any type of hinge ... the possibility of twist on tower and hinges at the base. Special care must ...

by the absence of any written objection and by the acceptance of part or all of the ... that: All proposals, negotiations, and representations regarding a transaction ... into this document. All delivery prices are FOB our point of manufacture, ... otherwise specified. The agreement and language herein shall be construed and ... the laws of the Province of Ontario and the federal laws of Canada, applicable ... reasonable conduct of business. Title and Risk of Loss Full risk of loss, ... including transportation delays and losses, shall pass to you upon delivery ... , may repossess all unpaid products and charge you with any deficiency. Terms ... . Credit Approval Shipment, deliveries, and performance of work shall at all times ... of payment or security, or upon terms and conditions satisfactory to us. Taxes ...

456 1. All quotation, proposals, prices, or other terms are made for acceptance ... within 60 days (after 60 days, prices in effect at time of shipment will ... apply) and shipment within 60 days of purchase ... . They are also subject to Credit and Marketing Department approval prior to ... acceptance. No other price protection is available. 2. Every ... , weather, detours, etc. All deliveries and schedules are contingent on ... availability of raw materials, fuel, and transportation. We will not be liable ... the right to make partial shipments and to submit invoices accordingly. 3. ... , which agreement shall include any price modification. 4. Rohns responsibility ... factory has been carefully inspected and Rohn does not assume responsibility for ... in transit. Buyer must make all claims and report all damages and losses to the ...

GENERAL INFORMATION AND PRECAUTIONS IF YOU NEED HELP FROM ... to government regulations, be sure you and your customers are informed as to ... with ROHN products is dangerous and voids all engineering or warranty data ... -called copies are not the same quality and have not been tested or engineered by ... Mixing of ROHN items may endanger lives and cause serious failures and financial ... ROHN PRODUCTS Installing, dismantling and rigging ROHN products requires ... specialized skills and experience. Information supplied by ... by personnel having these skills and having worked with similar products ... ROHN products without these skills and experience. Radian assumes no liability ... are used. There are available trained and experienced personnel to assist in ... installation, maintenance, and disassembly. Contact your local ...