Technical System Catalogue CMC III Monitoring System 2017 by Rittal

More catalogs by Rittal | Technical System Catalogue CMC III Monitoring System 2017 | 17 pages | 2017-04-27

Ads

Contacts for Rittal

Rittal GmbH & Co. KG
Auf dem Stützelberg
D-35745 Herborn

Telephone: +49 (0) 2772 / 505 - 0
Fax: +49 (0) 2772 / 505 - 2319
E-mail: info@rittal.de
http://www.rittal.com/com-en/

Technical System Catalogue CMC III Monitoring System 2017 is listed under these categories

Industrial Supply > Electrical & Test

Featured catalog pages of Technical System Catalogue CMC III Monitoring System 2017

cmc iii monitoring system cmc iii processing unit compact the cmc iii processing unit and the cmc iii processing unit compact are the heart of a cmc iii system this is where all measured values are summarised evaluated and forwarded a cmc iii processing unit compact is the interface between a cmc iii system and the user it is incorporated into the company network and utilises an integrated website to make current values available to every authorised user a cmc iii processing unit compact can be powered both in a redundant system via two power packs and using poe delivered via the connected network cable the system can be fitted very easily and quickly in the enclosure and incorporates a mounting unit for the enclosure frame and a 1 u mounting unit for up to three devices that can be installed in the 19 section in the enclosure each cmc iii processing unit compact has four sensors already integrated as standard besides a socket for the temperature sensor included in the scope of

cmc iii sensors for direct connection temperature sensor cmc iii sensor with internal temperature sensor for in-airflow applications or alternatively with external temperature sensor for all application scenarios ◾ ◾ ◾ ◾ ◾ ◾ ◾ ◾ max number of cmc iii processing units 32 max number of cmc iii processing units compact 4 measurement range of internal sensors +0°c…+55°c measurement range of external sensors -40°c…+80°c jack for external sensor 1 rj 45 can bus jacks 2 wxhxd 80 x 28 x 40 mm colour ral 9005/7035 temperature/humidity sensor cmc iii sensor with temperature sensor and humidity sensor in the enclosure front ◾ ◾ ◾ ◾ ◾ ◾ ◾ max number of cmc iii processing units 32 max number of cmc iii processing units compact 4 temperature measurement range +0°c…+55°c relative humidity measurement range 5 %…95 rh rj 45 can bus jacks 2 wxhxd 80 x 28 x 40 mm colour

cmc iii sensors for direct connection analogue airflow sensor cmc iii sensor with analogue sensor for measuring air speed e.g for fan monitoring ◾ max number of cmc iii processing units 10 ◾ max number of cmc iii processing units with power supply via poe 5 ◾ max number of cmc iii processing units compact 4 ◾ sensor interface 4 – 20 ma ◾ measurement range 0.5 to 10 m/s ◾ rj 45 can bus jacks 2 ◾ terminals for airflow sensor 1 ◾ wxhxd 110 x 30 x 40 mm ◾ colour ral 9005/7035 analogue differential pressure sensor cmc iii sensor with analogue pressure sensor for monitoring a pressure differential e.g for climate-control applications tubing included in the scope of supply can be used to specify two points in the room where pressure is measured the difference between these two pressure measurements is depicted as the measured value and monitored ◾ ◾ ◾ ◾ ◾ ◾ ◾ max number of cmc iii

cmc iii sensors for direct connection cmc iii smoke alarm the cmc iii smoke alarm is fitted at the top of the enclosure and monitors the air inside the enclosure for smoke particles settings can be made via the cmc iii processing unit â—¾ max number of cmc iii processing units 32 â—¾ max number of cmc iii processing units compact 4 â—¾ measuring method silicon pin photodiode/gaas infrared led â—¾ rj 45 can bus jacks 2 â—¾ diameter 100 mm â—¾ h 50 mm â—¾ colour white cmc iii leak sensor the cmc iii leak sensor has an external sensor mounted so that the contacts are pointing vertically down to the floor these two contacts monitor a point on the floor for liquids leakage settings can be made via the cmc iii processing unit â—¾ â—¾ â—¾ â—¾ â—¾ â—¾ â—¾ max number of cmc iii processing units 32 max number of cmc iii processing units compact 4 measuring method conductivity measurement rj 45 can bus jacks 2 terminals for leak sensors 1

cmc iii interface modules cmc iii can bus unit the cmc iii can bus unit acts as an interface between the cmc iii processing unit and the psm measurement bars and modules the unit has four connections two connections represent the interface to the can bus and to the other cmc iii sensors while up to four psm modules i.e a total of up to eight psm modules per cmc iii can bus unit or one measurement bar can be connected to each of the other two connections when connecting psm modules the cmc iii can bus unit must be externally supplied with 24 v via terminals â—¾ max number of cmc iii processing units 4 â—¾ max number of cmc iii processing units with power supply via poe 1 â—¾ max number of cmc iii processing units compact 1 â—¾ rj 45 interfaces 2 cmc-tc units â—¾ rj 45 can bus jacks 2 â—¾ wxhxd 138 x 40 x 120 12 mm front â—¾ colour ral 9005/7035 connection information 1 2 the following sensors can be connected to the cmc iii can bus unit cmc iii can bus unit

cmc iii access control cmc iii can bus access cmc iii unit for controlling and monitoring access to enclosures one handle and one reader unit can be connected to each cmc iii can bus access the handles can be linked to various numerical codes or rfid card numbers via the cmc iii processing unit compact website which means that all the handles connected to a cmc iii processing unit compact can be controlled with just one reader unit the integral infrared sensor also ensures that the status of the controlled door open/closed is monitored â—¾ max number of cmc iii processing units 16 â—¾ max number of cmc iii processing units with power supply via poe 5 â—¾ max number of cmc iii processing units compact 4 â—¾ transmitter infrared diode â—¾ receiver infrared receiver â—¾ interfaces 1 cmc iii reader unit â—¾ rj 12 interfaces 1 handle electromechanical â—¾ rj 45 can bus jacks 2 â—¾ wxhxd 110 x 30 x 40 mm â—¾ colour ral 9005/7035       

cmc iii access control electromagnetic handle the handle locks the door and monitors the lever it can always be opened independently of the control system using the master key a semi-cylinder lock insert lock no 3524 e is included in the scope of supply but a semicylinder with an overall length of 40 mm to din 18 254 can also be used a can bus access dk 7030.200 must be fitted on the rack frame for each handle this device has an integrated infrared access sensor and the handle and a reader unit can be connected if the lever handle is closed the locking mechanism integrated into the handle latches automatically the handle can be released via the cmc iii system in the network or via optional add-on systems such as mifare transponder readers the handle locks without consuming any voltage no electrical connection once the electrical release has been issued the push-button can be pressed to release the lever the enclosure must be opened within a specified period of time that is set in the

cmc iii accessories cmc iii gsm unit a module for a redundant alarm signal can be connected to each cmc iii processing unit compact the gsm unit quadband forwards the alarm notifications as an sms to up to 16 recipients via gsm â—¾ frequency range 850/900/1800/1900 mhz â—¾ wxhxd 138 x 40 x 120 mm â—¾ front 12 mm cmc iii isdn unit a module for a redundant alarm signal can be connected to each cmc iii processing unit compact the isdn unit forwards the alarm notifications as an sms to up to 16 recipients via isdn â—¾ dss1 euro-isdn â—¾ wxhxd 138 x 40 x 120 mm â—¾ front 12 mm cmc iii interference suppressor for fans when using the power unit it is important to suppress interference from the fan motors that it operates to do this the interference suppressors for each fan must be connected directly to the motor each interference suppressor incorporates a capacitor and a resistor cmc iii cable clamp straps for securing to the rear of the cmc iii 19 mounting unit

cmc iii – monitoring system cmc iii processing unit system overview can bus 1 mini usb programming cable 7030.080 is required for programming cmc iii sensors for direct connection 0° internal infrared access sensor can bus 2 sd card slot for data logging cmc iii can bus sensor as adaptor for cmc ii sensors cmc iii processing unit voltage supply 24 v dc and redundant voltage supply 24 v dc cmc iii can bus access with integrated infrared access sensor alarm relay output changeover contact for safety extra-low voltage ethernet 10/100 baset rj 45 with poe ethernet interface to ieee 802.3 via 10/100 baset full duplex 10/100 mbit/s rj 12/rs 232 accessory modules display unit isdn unit gsm unit external temperature sensor included in scope of supply for pu up to 16 can bus systems are supported1 usb master for data logging and update 1 depending on the power supply connection combinations two integral digital inputs control units cmc iii i/o unit cmc iii power unit up to 16 can bus

cmc iii – monitoring system cmc iii processing unit compact system overview mini usb programming cable 7030.080 is required for programming up to 4 can bus components are supported1 cmc iii sensors for direct connection internal infrared access sensor 0° can bus 1 cmc iii processing unit compact cmc iii can bus sensor as adaptor for cmc ii sensors voltage supply 24 v dc and redundant voltage supply 24 v dc alarm relay output changeover contact for safety extra-low voltage cmc iii can bus access with integrated infrared access sensor ethernet 10/100 baset rj 45 with poe ethernet interface to ieee 802.3 via 10/100 baset full-duplex 10/100 mbit/s rj 12/rs 232 accessory modules display unit isdn unit gsm unit external temperature sensor included in scope of supply for puc two integral digital inputs note server shutdown software for cmc iii is required to shut down the server 16 rittal technical system catalogue/it