43 results for filter p 1 found in 0.000 seconds

Laboratory Products by Sartorius

Catalog: Laboratory Products
Company/Brand: Sartorius



filter p 1 in Laboratory Products by Sartorius


 
Show page 11
comparison of the adsorption of various filter materials 139.6 40 how ready-to-connect ... scale-up the combination of the large filter area and the optimized geometry of the ... filter supports of minisarts and sartolab p20 ... units ensure high flow rates at low pressures and optimal throughputs often the ... filterable volume can even be doubled by using ... minisart-plus or sartolab p20 plus units with an integrated prefilter ... sartobran 150 and 300 and sartobran p capsules contain a pleated double ... compliance all units are comprised of practice-proven cellulose acetate or polyethersulfone ... membrane filters tested according to hima each single ... for housing and membrane integrity prior to packaging and statistically valid ...
 
Show page 16
adsorption cellulose acetate membrane filters type 111 for the filtration of aqueous ... therefore excellently suited for use in pressure filtration devices the 0.2 µm membrane ... is the filter of choice for sterile filtration of ... media buffers and sera the results of publications on adsorption are difficult to ... and the membranes were tested without previous sterilization filtration membrane ... filters for liquid samples typical performance for cellulose acetate membrane filters ... adsorption bubble point acc din 58355 bovine serum albumin <10 ... automatic integrity tester for 0.45 µm 1.9 bar 190 kpa 27.5 psi for 0.65 µm 1.3 ... bar 130 kpa 18.9 psi for 0.8 µm 0.8 bar 80 kpa 11.6 psi ...
 
Show page 19
polyethersulfone membrane filters type 154 for the filtration of aqueous and ... aggressive solutions filtration the new polyethersulfone membrane filters feature excellent flow ... speeds and a high filterable volume biologic and pharmaceutic ... solutions can be filtered in the wide ph-range of ph 2-12 because of their low protein ... of the environmental sector the 0.1 µm filters are used for the ultracleaning of ... e.g in the case of nephelometry typical performance for polyethersulfone membrane filters ... adsorption bubble point acc din 58355 10 µg/cm2 for igg 5 µm/cm2 for bsa 1.9 µg/ ... cm2 for insulin 0.1 µm with isopropanol/water 60/40 >2.1 ... bar 30.45 psi 0.2 µm 3.2 bar 320 kpa 46 psi 0.45 µm ...
 
Show page 20
cellulose nitrate ester membrane filters type 113 for sample pretreatment ... particle testing and chemotaxis cellulose ... is a standard material for membrane filters and offers a wide range of pore sizes ... from 8 µm to 0.45 µm the larger pore sizes 8 µm 5 µm 3 µm can be used for ... and cell retention the 0.45 µm pore size for particle collection the high ... adsorption decreases with increasing pore size as shown in the diagram filtration ... membrane filters for liquid samples typical performance ... for cellulose nitrate ester membrane filters adsorption bubble point acc din 58355 ... minimum values 0.3 bar 30 kpa 4.35 psi for 8 µm pore size 11301 0.5 bar 50 kpa ... 7.25 psi for 5 µm pore size 11342 0.6 bar 60 kpa 8.7 psi for 3 µm pore ...
 
Show page 22
polyamide membrane filters type 250 for the filtration of alkaline ... solutions and organic solvents polyamide membrane filters are hydrophilic and ... they are therefore recommended for particle-removing filtration of water aqueous solutions ... adsorption cellulose acetate membrane filters type 111 described on page 16 are ... recommended membrane filters for liquid samples n typical ... performance for polyamide membrane filters adsorption bubble point acc din 58355 ... 100 µg/cm2 for bovine serum albumin 0.2 µm ... pore size minimum value for 0.2 µm 3.4 bar ... 340 kpa 49.3 psi for 0.45 µm 2.2 bar 220 kpa 33.35 psi ... to many solvents and alkali-solutions ph range 3-14 less than 1 average value ...
 
Show page 23
hydrophobic ptfe membrane filters type 118 for the filtraton of air gases or ... the main application of this membrane filter type is air |gas filtration they are ... made purely of ptfe polytetra-fluorethylene and are therefore permanently ... hydrophobic unlike other hydrophilic filter types they are not wetted by air ... humidity allowing unhindered passage of air at low differential pressures as ... well ptfe membrane filters have an excellent chemical ... of solvents and acids to which other filter types are not resistant due to their ... characteristics they must be pre-wetted with ethanol or methanol before the ... of aqueous media filtration membrane filters for liquid samples n typical ...
 
Show page 26
glass fiber prefilters for larger totally filterable volumes ... the major use of all three glass fiber filters is as a depth prefilter placed directly ... on top of a membrane filter whereby the prefilter diameter ... and cause leakage the standard type 13400 contains an acrylic latex binder it has ... a high particle loading capacity but for very dirty ... liquids the thicker type 13430 can be more effective type 13440 is a ... -free type and is recommended for the prefiltration of relatively clean solutions such as ... may be necessary for difficult to filter liquids such as serum two or three ... membrane filters of different pore sizes are placed on each other with a ... glass fiber prefilter on top and 13420 polyester separators between them diameter as ...
 
Show page 29
minisart® 0.2 µm syringe filter holders for rapid small volume ... offer high flow rates at low inlet pressures make correspondingly rapid sterile ... filtration possible fitted on a standard syringe they ... tiresome sterilization of up to 100 ml of liquid a minisart fitted on a ... area and an optimized geometry of the filter support which are responsible for the ... ensures high total throughputs minisart plus units are advantageous for the ... sterilization of difficult to filter liquids they include a fine glass fiber ... prefilter on the filter membrane a combination which is so ... often be doubled minisarts and their packaging are environmentally friendly free of ... pvc minisart high flow are syringe filter holders with a polyethersulfone ...
 
Show page 32
filtration ready-to-use syringe filter units for simple rapid and reliable ... rc25 for sample volumes of up to about 100 ml minisart rc units outperform ... mixtures applications for syringe filter holders they are compatible with the ... methylethylketone diethyl acetamide pentane dimethyl sulfoxide tetrahydrofuran ... rc4 rc15 and rc25 connectors bubble point with water flow rate for hexane at p 1 ... bar 100 kpa 14.5 psi minisart rc4 minisart rc15 minisart ... rc25 flow rate for methanol at p 1 bar 100 kpa 14.5 psi minisart rc4 minisart ... minisart rc25 flow rate for water at p 1 bar 100 kpa 14.5 psi minisart rc4 ... minisart rc15 minisart rc25 filter diameter filter area filling volume ...
 
Show page 33
volume outlet connector inlet connector pore size order number 50 units order number ... 500 units housing material membrane filter material membrane filter diameter ... filter area priming volume maximum pressure max temperature autoclave flow rate for ... water at p 100 kpa 1 bar order numbers for minisart rc4 ... 17821 k 17821 q 17822 k 17822 q order numbers for minisart rc15 17761 ... k 17761 ack 17761 q 17762 k 17762 q order numbers for minisart rc25 17764 ... k 17764 ack 17764 q 17765 k 17765 q ca 0.15 ml luer slip 0.2 µm 17845 ack ... sterile individually packed 17845 q polypropylene nylon 25 mm 4.8 cm 2 0.45 µm 17846 ack ... sterile individually packed 17846 q polypropylene nylon 25 mm 4.8 cm2 ca 0.95 ml 600 kpa ...
 
Show page 34
units with a clean and chemically inert ptfe membrane ready-to-use units for simple ... for sample volumes of up to about 1 ml minisart srp15 for up to about 5 ml ... and minisart srp 25 for up to 100 ml applications for syringe filter ... srp4 srp15 and srp25 connectors bubble point flow rate for ethanol at p 1 bar 100 ... kpa 14.5 psi minisart srp4 minisart srp15 minisart ... srp25 flow rate for methanol at p 1 bar 100 kpa 14.5 psi minisart srp4 ... minisart srp25 flow rate for air at p 1 bar 100 kpa 14.5 psi minisart srp4 ... minisart srp15 minisart srp25 filter diameter filter area housing burst ...
 
Show page 36
re-usable 13 mm syringe filter holders for the ultracleaning of small ... volumes up to about 10 ml ptfe holder for solvents and chemicals made ... completely of ptfe this holder is unaffected by chemicals ... could be released into the liquid being filtered it is therefore extremely well suited ... for particle removal from samples and reagents for ... and the drying at a temperature of 180°c the construction of the holder ensures ... leak proof sealing without a sealing ring and ... avoids twisting of the membrane filter when the top is tightened onto the base ... applications for syringe filter holders specifications for the 13 mm ... ptfe syringe filter holder connectors chemical ... compatibility flow rate for water at p 1 bar 100 kpa 14.5 psi with 0.2 µm ...
 
Show page 37
filter supports in the top and bottom parts allow filtration in either direction ... specifications for the 13 mm polycarbonate syringe filter holder connectors ... compatibility flow rate for water at p 1 bar 100 kpa 14.5 psi with 0.2 µm ... membrane filter with 0.45 µm membrane filter membrane filter filtration area ... luer lock inlet luer slip outlet as for polycarbonate and silicone approx 18 ml/min 35 ml/min ... 35 ml/min with 0.45 µm membrane filter 0.5 cm2 polycarbonate top and bottom ... part silicone gasket 10 14.9 mm replacement part no 6980569 for a ... pack of 10 7 bar 700 kpa 101.57 psi 13 mm by autoclaving at 121°c less than 0. ...
 
Show page 38
re-usable 25 mm syringe filter holders for the ultracleaning and ... filtration of volumes of up to about 100 ml stainless steel holder for solvents ... and chemicals the ptfe-coated surface on the top part is an important ... property of the filter holder and ensures leak-proof sealing ... depends only on the inserted filter type filtration the top part can easily ... be mounted on the bottom part using the enclosed tightening tool ... filter supports in the top and bottom parts allow filtration in either direction ... applications for syringe filter holders specifications for the 25 mm ... compatibility flow rate for water at p 1 bar 100 kpa 14.5 psi with 0.2 µm ...
 
Show page 39
specifications for the 25 mm polycarbonate syringe filter holder connectors ... compatibility flow rate for water at p 1 bar 100 kpa 14.5 psi with 0.2 µm ... membrane filter with 0.45 µm membrane filter filtration area materials female luer ... lock inlet luer slip outlet as for polycarbonate and silicone 70 ml/min 110 ml/min 3 cm2 ... polycarbonate top and bottom parts silicone flat gasket 20 25 mm ... replacement part no 1eds-d0053 for a pack of 10 7 bar 700 kpa 101.5 psi 25 mm by ... autoclaving at 121°c less than 0.3 ml after overcoming the ... bubble point 0.6 ml before max operating pressure ... membrane filter diameter sterilization hold-up volume ...
 
Show page 51
sartolab® p20 and sartolab® p20 plus for reliable sterile filtration of ... solutions filtration applications for pressure filtration units ready-to-use units ... which attached to a membrane pump or tube pump quickly and reliably ... sterilize 100 ml to 5 liter of media and aqueous ... venting of any trapped air through the ptfe membraneprotected vent ports ensures ... that the entire filter surface is used for effective ... filtration sartolab p20 units have an extraordinarily favorable ... price-performance ratio often the total filterable volume ... an integrated binder-free glass fiber prefilter v ml 150 sartolab-p20 plus sartolab-p20 ... specifications for sartolab p20 units connectors biosafety inlet luer ... lock inner cone or 6­12 mm stepped hose nipple outlet 6­12 mm ...
 
Show page 55
sartobran® p 150 and sartobran® p 300 capsules optimum convenience for up ... volumes newly developed ready-to-use pressure filtration units offering maximum ... for the sterile filtration of 0.1 to 50 liters of buffers infusion ... sera and other solutions containing proteins no more problems with air bubbles in ... the liquid a hydrophobic ptfe membrane validated for sterile air ... air bubble collection at the highest point upstream at the beginning of the ... vent away and full use of the complete filter area is guaranteed during this venting ... the ptfe membrane prevents liquid from emerging thus protecting ... drops and the environment and user from possible contamination for the subsequent ... be closed with the closure sartobran p 150 and sartobran p 300 filter capsules ...
 
Show page 56
sartobran® p midicaps for the filtration of protein ... containing solutions sartobran p midicaps are designed for maximum ... convenience and performance they are complete filter units ready- ... toconnect and to-use without prior cleaning although intended for single ... the smaller sartobran-300 capsules the pleating of the membranes allows large filter ... to be sealed in small handy units the polypropylene housing contains two membrane filters ... the first coarser membrane acts as a prefilter relieving the next finer membrane,which ... a reliable retention according to pore size this fractionated retention of ... particles and microorganisms has a very favorable ... of relatively high colloid content was filtered filtration applications for pressure ...
 
Show page 57
with 0.2 µm final filter and 0.45 µm prefilter type oo with 1 hose nipple inlet and ... nipple inlet and outlet type ss with 11 sanitary flange inlet and outlet ... a 5235307h9-ss-a 5235307ho-ss-v 0.05 m2 filter area pack of 4 0.1 m2 filter area pack ... of 4 0.2 m2 filter area pack of 4 0.45 m2 filter area pack of 2 type ... so with 11 sanitary flange inlet and 1 hose nipple outlet 5235307h7-so-a ... a 5235307h9-so-a 5235307h0-so-v 0.05 m2 filter area pack of 4 0.1 m2 filter area pack ... of 4 0.2 m2 filter area pack of 4 0.45 m2 filter area pack of 2 type ... inlet and outlet 5235307h7-hh-a 0.05 m2 filter area pack of 4 type ff with 3 sanitary ...
 
Show page 60
rates and standing times over the whole ph-range the new sartopore 2 midicaps ideally ... supplement the sartobran p filters described on page 56 whereas sartobran ... p filters are mainly used for prefiltration and sterile filtration of protein- ... containing solutions in the ph-range of 4­8 the broad chemical compatibility ... of the polyethersulfone membranes from ph1 to ph 14 of the sartopore 2 filter ... of aggressive liquids of high or low ph sartopore 2 midicaps are available with ... three different pore sizes for the prefiltration of difficult to filter solutions ... .45 µm final membranes are used whereas filter elements with 0.2 µm final membranes ... of media sartopore 2 midicaps with 0.1 µm final membranes are perfectly ...
 
Show page 62
midicaps for the particle removing filtration or prefiltration of ... 100 liters and more each of these ready-to- ... contains a multi-step combination of filters for effective and economical particle ... removal these filters are either used alone or as a prefilter ... in combination with a sartobran p or sartofluor midicaps there is a ... different types differing only in the filters they contain all other parts are the ... same and made of polypropylene sartopure pp2 midicaps depth-type ... filters containing progressively finer polypropylene fleeces for the retention of particles ... six retention efficiencies of 20 8 5 3,1.2 and 0.65 µm major applications particle ... -removing filtration of deionized water pharmaceutical solutions reagents chemicals acids ...
 
Show page 66
are caused by tap water used for the patients personal hygiene e.g washing showering ... of drinking and service water at the point of use is recommended the successful ... of safety filtration applications for pressure filtration units biosafety bubble point ... flow rate final pressure filtration area materials sterilization ... all components pass the usp plastics­class vi-test with water min value 3.2 bar ... 320 kpa 46 psi for water at p 3 bar 300 kpa 43.5 psi ca 12 l/min ... max p 4 bar 400 kpa 59 psi at 20°c 2 bar 200 kpa 29 psi at 80°c 0. ... 1 m2 size 8 0.05 m2 size 7 cellulose ... acetate membrane filter double-layered 0.45 µm on 0.2 µm pore ... size polypropylene support and housing by autoclaving 121° ...
 
Show page 67
mini filter cartridges for the particle-removing filtration or prefiltration of 100 ... mini cartridges contains a series of filters with increasing fineness for effective ... and economical particle removal either as an independent filter ... or as a prefilter in combination with a sartobran p or ... four different types differ only in the filter combinations all other parts are the ... same made of polypropylene support framing or silicone sealing ... ring sartopure pp2 mini cartridges they contain ... polypropylene fleeces of increasing fineness for ... efficiency 20 µm 8 µm 5 µm 3 µm 1.2 µm and 0.65 µm main applications ... particle-removing filtration of deionized water ... pharmaceutical solutions chemicals and solvents and ...
 
Show page 69
sartoclear® p depth filter capsules for bench scale trials ... description sartoclear® p caps are especially developed to serve ... and clarification applications the product features encapsulated cellulose based ... depth filter media with highest dirt holding ... capacity sartoclear® p caps are being manufactured using the ... system applications sartoclear® p caps are being used as single use ... up trials and small scale manufacturing filter area each sartoclear® p cap contains an ... effective filter area of 25 cm2 product benefits sartoclear® p caps are ... disposable capsules this technology provides highest flexibility for disposable ... and scale up work sartoclear® p caps can be simply and directly ...
 
Show page 70
specifications materials depth filter media core capsule housing retention ... s5p s9p 25 cm2 max allowable system pressure max allowable pressure differential max ... allowable back pressure 5.5 bar |80 psi at 20°c 2.0 bar |29 psi 0.03 bar |0.4 ... psi cellulosic depth filter media with inorganic filter aids ... polypropylene polypropylene 8 µm 4 µm 1.5 µm 1 µm 0.3 µm 0.1 µm applications for ... pressure filtration units filtration area ... operating parameters technical references directions for use ... 85030-521-62 order information 293 c4p 13 a c ff -m sartoclear® p retention rate ... pharma biotech capsule design internal code 25 ... inlet outlet dash|space 3 capsules per box 70 ...
 
Show page 71
low-cost polycarbonate holder for the filtration of liter ... holder is made of stable autoclavable polycarbonate this practical holder is suitable for ... filtrations it can be connected to a peristaltic pump or a pressure container the bell- ... shaped base protects the filtrate from repeated ... by an excellent resistance to pressure and density setting by simply hand- ... tightening the transparent top part allows the visual control of the ... to use it as a large area syringe filter holder filtration applications for ... pressure filtration units specifications for the ... 50 mm polycarbonate filter holder chemical compatibility flow rate ... as for polycarbonate polypropylene and silicone for water at p 1 bar 100 ...
 
Show page 72
25 mm stainless steel filter holder for in-line filtration ... applications for pressure filtration units the 25 mm filter ... with density barrel guaranteed leak-proof sealing of the hose nipple and the ... fit the holder onto reducing valves or pumps with g1/4 female thread order no 01030 ... or g3/8 female thread 01029 or onto pressure tanks with g3/8 male thread 00177 ... rate hose nipples dn10 3 cm2 for air at p 1 bar 14.5 psi 0.5 l/min with 0.2 µm ... 1.0 l/min with 0.45 µm pore size ca 170 g stainless steel except silicone o- ... closing ring 5 bar 500 kpa 72.5 psi 25 mm type 118 by autoclaving max 134°c ... or by dry heat max 180°c 6981031 top part 6981033 silicone o-ring 6981032 base ...
 
Show page 73
47 mm stainless steel filter holder for in-line filtration ... specifications 6980722 valve 6980656 ptfe flat gasket 6980717 viton o-ring ... area flow rate hose nipples dn10 m12+1 13 cm2 for air at p 0.3 bar 4.35 psi 0.5 ... l/min with 0.2 µm 1.0 l/min with 0.45 µm pore size ca 490 g ... steel except silicone o-ring 42 3 mm ptfe and viton valve seals 20 bar 2,000 kpa ... 290 psi 47 mm type 118 by autoclaving max 134°c or by dry heat ... max 180°c 6982005 closing ring weight 6982003 ... top part 6980721 back pressure screen 6980178 silicone o-ring 6980180 ... screen support 6980737 support plate 6982006 base plate materials max ... operating pressure suitable membrane filter sterilization order number 16254 ...
 
Show page 74
chemical-resistant ptfe holders for the filtration of ... chemicals the viton o-ring in the top part allows easy hand tightening but can be ... replaced by a ptfe o-ring order no 17039 the 6 mm outlet nipple is an integral ... part of the base the 10 mm inlet hose nipple can be replaced by ... a g3/8 connector 17051 filtration applications for pressure ... specifications for the 47 mm 200 ml ptfe filter holder chemical compatibility ... flow rate as for ptfe and viton for water at p 1 bar 100 kpa ... 14.5 psi 170 ml/min with 0.2 µm 500 ml/min with 0.45 ... µm 1.4 l/min with 0.8 µm pore size 12.5 cm2 m 14+1.5 male thread top part ... barrel base part corrugated iron hose nipples and filter ...
 
Show page 75
specifications for the 142 mm ptfe pressure filter holder chemical compatibility ... filtration area weight materials as for ptfe with 0.2 µm membrane filter at p 0.5 ... bar 50 kpa 7.25 psi 1 l/min for water 1.6 l/min for ethanol 130 cm2 6 kg top part ... base back pressure screen filter support with 131+4 mm o-ring vent valve ... and ptfe hose nipples chromium plated holding frame plates aluminium legs 5 ... bar 500 kpa 72.5 psi by autoclaving max 134°c or by dry heat 180°c max operating ... pressure sterilization suitable membrane filter ... diameter 142 mm prefilter 130 mm order number for the 142 mm ptfe ... pressure filter holder 16540 replacement parts 6980700 6980705 ...
 
Show page 76
filtration of up to 5 liter volumes a practical holder for many laboratory filtrations ... is screwed into the side of the top part leaving room for a large filling ... opening this makes pouring in the sample easier and the sample can ... removing the tube connection to the pressure source leak-proof sealing is achieved ... the holder is connected directly to a pressure source for the filtration of up to 5 ... liter volumes of relatively easily filterable liquids e.g buffer solutions solutions ... it is used in combination with a pressure tank applications for pressure ... for the 47 mm 200 ml stainless steel pressure holder chemical compatibility as for ... stainless steel ptfe and silicone if required the silicone o ... -ring in the filter support can be replaced by a viton o- ...
 
Show page 77
holder with 2 liter capacity for sample preparation and sterile filtration of serum this ... device is perfectly suited for the removal of insoluble ... samples for the determination of the particular constituents of sludge that can be ... can be filled in with a large filling port allowing simple pouring of the liquid ... the pressure filtration avoids the loss of volatile ... components the filter are 130 cm2 which guarantees short filtration ... the sterile filtration of difficult-to-filter liquids such as serum up to three ... membrane filters with progessively finer pore sizes in direction of the ... of suspended material enlarges the filterable volume the swing-out locking clamps ... -tightening filtration applications for pressure filtration units specifications for the ...
 
Show page 78
142 mm stainless steel holder for the ... is very often used in laboratories for particle removal and for sterile filtration of ... to operate the large filtration area of 130 cm2 ensures high flow rate for the ... total filter volume the supplied unscrewable hose ... by g3/8 connectors if systems with particularly practical handling is required the ... of the air venting valve in the top plate and the test valve in the base plate ... ensures the necessary vapour penetration the back pressure screen has a smooth ... order to avoid damages of the membrane filters also when a glass fiber prefilter is ... hand-tightening specifications for the 142 mm holder with hose nipples chemical ... compatibility as for stainless steel ptfe silicone and viton if required the ...
 
Show page 79
gmp-complying 142 mm stainless steel holder with sanitary ... are sanitary flanges which are integral parts of the top and bottom plates they ... of the air venting valve in the top part and the sample removal/test valve in ... of the device with a mounted filter either by autoclaving or by in-line ... the swing-out clamps ensure leak-proof installation simply by hand-tightening ... the back pressure screen is very easy to mount and has a ... order to avoid damages to the membrane filter when being autoclaved even when no ... glass fiber prefilter is used filtration applications for ... pressure filtration units specifications for the ... 142 mm sanitary flange holder dimensions ... end of the legs as for stainless steel ptfe silicone and viton if required the ...
 
Show page 80
this holder is the same as that of the 142 mm holder described on page 79 except ... steel in order to avoid corrosion problems as is sometimes the case with aluminium ... mechanism of the locking clamps is very practical as there are 6 clamps the holder offers ... the same advantages for the user as the 142 mm holder however the filtration area ... and the in-service life is longer the filter support is designed for the maximum ... exploitation of the filter area and minimum flow resistance as is ... increase of flow rates with increasing pore sizes see diagram filtration ... applications for pressure filtration units specifications for the ... width 416.5 mm as for stainless steel ptfe silicone and viton if required the ... no 6982077 viton o-rings 6982078 or ptfe o-rings 6982079 reduce the max ...
 
Show page 82
accessories for pressure filtration units filtration the ... required depend on the type of the pressure filtration unit re-usable units with ... barrels to hold the liquid to be filtered can be connected to a pressure source ... pressure pump or nitrogen bottle after insertion of ... the membrane filter and prefilter and if necessary after sterilization ... and pouring in of the liquid when using ready-to- ... and mini cartridge housings the filterable liquid must be fed in on the inlet side ... out of an open container through a peristaltic or impeller pump or out of a ... pressurized conduction system or a pressurized container various systems with ... pressurized containers are described on the next ... page recommended accessories 1 for sartolab p20 units units with a ...
 
Show page 95
hydrophobic ptfe membranes type 118 for the filtraton of air gases or ... the main application of this membrane filter type is the air/gas filtration they are ... made purely of ptfe polytetra-fluorethylene and are therefore permanently ... hydrophobic unlike other hydrophilic filter types they are not wetted by air ... humidity allowing unhindered passage of air also at low differential ... pressures ptfe membrane filters have excellent chemical compatibility ... of solvents and acids to which other filter types are not resistant due to their ... characteristics they must be pre-wetted with ethanol or methanol before the ... of gases n specifications for ptfe membrane filters adsorption bubble ...
 
Show page 97
25 mm stainless steel filter holder for in-line filtration 6980176 ... rate hose nipples dn10 3 cm2 for air at p 1 bar 14.5 psi 0.5 l/min with 0.2 µm ... 1.0 l/min with 0.45 µm pore size ca 170 g stainless steel except silicone o- ... closing ring 5 bar 500 kpa 72.5 psi 25 mm type 118 by autoclaving max 134°c ... or by dry heat max 180°c 6981031 top part 6981033 silicone o-ring 6981032 base ... part weight materials max opperating pressure suitable membrane filter sterilization ... ring 6980176 connector order number 16251 stainless steel holder for 25 mm d ... membrane filter replacement parts are shown in the diagram 97 sterile ... filtration of gases the 25 mm filter holder the g1/4 connection threads with ...
 
Show page 98
47 mm stainless steel filter holder for in-line filtration sterile ... filtration of gases the 47 mm filter holder tolerates pressure of up to 20 ... fit the holder onto reducing valves or pumps with g3/8 female thread order no 17089 ... or onto pressure tanks with g3/8 male thread 17069 or on ... taps with g3/4 male thread 17068 filtration specifications 6980722 ... valve 6980656 ptfe flat gasket 6980717 viton o-ring ... area flow rate hose nipples dn10 m12+1 13 cm2 for air at p 0.3 bar 4.35 psi 0.5 ... l/min with 0.2 µm 1.0 l/min with 0.45 µm pore size ca 490 g ... steel except silicone o-ring 42 3 mm ptfe and viton valve seals 20 bar 2,000 kpa ... 290 psi 47 mm type 118 by autoclaving max 134°c or by dry heat ...
 
Show page 99
sartofluor mini cartridges are designed particularly for cases of sterile venting when the ... to the sealing system an inner o-ring plus bayonet twist lock guarantees safe ... housings and a firm hold for back pressure pushes the inserted specially developed ... ptfe membranes are extremely water-repellent ... impressively by the very high water penetration pressure the diagram shows values for ... various 0.2 µm filter materials due to the optimal ... flow rates in shortest time water penetration pressure bar 6 5 4 3 2 1 0 sartofluor ... pvdf alternative products ptfe ptfe pvdf abcda 5181407t7 b 5181507t7 c ... 5181507t9 air flow rates at atmosperic pressure sartofluor® mini 0.2 µm type 5181507t7 ...
 
Show page 119
chemical compatibility 1 filter materials and mini cartridges ... ketone monochlorobenzene nitrobenzene n-pentane perchloroethylene pyridine carbon ... 111 ­ · · cellulose nitrate 113 ­ · · reg cellulose 184 ... · · · · · · · · · · · · · ptfe polyamide 250 ­ ­ · · · · · · · · · glass fiber ... 134 ... polycarbonate 230 polyethersulfone 154 ... v ­ v v ­ ­ ­ sartobran p cartridge sartofluor cartridge 118 ... key to symbols see next page 119 ...
 
Show page 141
specifications of gelatine filters gelatine filters water soluble pore ... max 60°c 46-49 approx 2.7 l/min cm2 at p 0.05 bar 1 bac subtilis niger spores ... .9995 at 0.25 m/s inlet velocity 2 coli phages phage t1 99.9 at 0.3 m/s inlet velocity ... and 50 rel air humidity phage t3 99.94 at 0.3 m/s inlet velocity and ... max 30°c max air humidity 85 supplied presterilized by gamma irradiation thermal resistance ... disposable gelatine units sterile pack of 10 order number 17528 80 acd 17528 ... 80 bzd 17528 80 vpd individually packed in 1 polyethylene bag each individually ... packed in 3 polyethylene bags each individually packed in 3 ... polyethylene bags each but label on innermost bag ...
 
Show page 299
application|product name ma35|ma100|ma150 moisture ... airscan® md8 calibration unit me series premium semi-micro and analytical balances ... media membrane filters for liquid samples membrane pump ... membrane pump for pressure metrological weights and weight sets ... -dismembrator minisart 0.2 µm syringe filter units minisart gf syringe filter units ... small containers and bottles minisart plus syringe filter units minisart rc ... syringe filter units minisart srp syringe filter units ... minisart standard syringe filter units multi-branch manifolds ... analysis nutrient media broth nutrient pad sets in petri dishes oem products page ... 280 268 138 142 246 156 16 83 83 270 90 222 29 30 90 30 32 34 30 ... 170 279 164 156 276 application|product name peristaltic pump ph|atc ...
 
 
  Similar searches   filter p 1 (862)
fuel filter p 23 (72)
p trap 1 (154)
1 14 filter adapter (298)
heavy duty 1 inch steel p clamps (9)
vw type 1 oil filter kit (29)
ss 600 1 6 p (37)
jaguar mk 1 air filter (12)
1 inch chrome p clamp for (14)
mirage frx 1 (113)
e type air filter (257)
decal kit 69 mach 1 (6)
03 beetle tdi fuel filter replacement (30)
remote oil filter (261)
fuel filter replacement (810)
polo 1 2 s 64 ps (17)
10 1 (37)
1 9l ford turbo (100)
1 9l ford turbo kit (44)
1 ton truck (510)
p 12 magazines (253)
p o cruises uk (15)
p o holiday cruise uk (11)
p o cruise ships (169)
p o european cruise ships (8)
fuel filter base (376)
bmw serie 1 (86)
ndl t p (17)
170 1 4 (33)
1 116 28 (486)
1 4 bspp (80)
can filter 2600 (18)
oil filter bypass valve (107)
su filters (79)
1 4 36 uns 2a (28)
p t o control tower (17)
69 mach 1 hood paint (8)
hearing aid filters (30)
1 58 exhaust tips (73)
p s 661 (134)
air filter yamaha (37)
oil filter adapter mount (266)
1996 oil filter adapter mount (11)
ford transmission filter (241)
1 14 acme (44)
ruger p 944 (6)
1 square white (573)
water mercury filter (69)
fuel filter flange (146)
jaguar fuel filter (47)
bmw 1 series (90)
elementary italian 1 (49)
83 cougar filters (6)
1 716 12 point socket (10)
micron filter (321)
p 205 (597)
filter capacitor list (29)
ruger 1 bore guide (10)
ev 1 cam (53)
fuel filter element (361)
oil filter adapter (469)



Home | Latest catalogs | Contact

© 2006-2009 by who-sells-it.com