Catalog: Wood Construction Connectors 2006 Catalog
Company/Brand: Simpson Strong-Tie
6 x 6 post base in Wood Construction Connectors 2006 Catalog by Simpson Strong-Tie
product is individually selected based on the products steel specifications, ... achieve highest load value. 8d (0.131"x2 "), 10d (0.148"x3"), and 16d (0.162"x3 ... Specific Gravity Douglas Fir-Larch (DF) 625 psi 0.50 Southern Pine (SP) 565 psi 0. ... 750 psi 0.50 TimberStrand LSL (E=1.3x10 6) 680 psi 0.50 TimberStrand LSL (E 1. ... 5x10 6) 880 psi 0.50 Parallam PSL 750 psi 0.50 ... rod nuts becoming loose, requiring post-installation tightening. l. Top flange hangers may ... are common nails (0.162" dia. x 3 long) and cannot be replaced with 16d ... sinkers (0.148" dia. x 3 long) for full load value unless ...

3x Plate S Floor (100) Roof (125) GH46-6 4x6 3 6 4 6 2000 2000 7, 90, ... 121 170 GH46-8 4x6 3 6 4 8 2000 2000 GH48-6 4x8 3 6 6 6 ... 2000 2000 GH48-8 4x8 3 6 6 8 2000 2000 GH66-6 6x6 5 8 4 6 4000 ... 4000 GH66-8 6x6 5 8 4 8 4000 4000 GH68-6 6x8 5 8 6 6 ... 4000 4000 GH68-8 6x8 5 8 6 3 3 5 5 3 3 5 5 8 4000 4000 Code Ref. ... a 3x plate. 4. NAILS: 16d 0.162" dia. x 3 long. See page 16-17 for other nail ... . See Corrosion Information, page 6-7. INSTALLATION: Use all specified ... . See Corrosion Information, page 6-7. INSTALLATION: Use all specified ... ; see General Notes. Loads are based on test results using Simpsons SDS x3 ...

30 Anchors ANCHOR SYSTEMS Holdown and Post Base Anchor Solutions Simpson Anchor ... Systems products offer several post-installed anchorage solutions for holdowns and ... bases. Often times these products are used ... 145 3 2,550 2,195 2,235 1,385 4 2,655 2,605 1,385 2 1,805 1,315 1,750 4 ... 4,425 3,840 4,165 2,500 6 4,640 4,795 2,500 2 1,695 2,125 3,605 5 ... 6,680 5,720 3,925 5 6,505 3,925 9 8,350 7,920 3,925 3 3,865 ... 3,250 5,090 6 10,525 8,865 9,405 5,090 11 11,910 10 ... ,595 5,090 3 4,780 3,550 6,870 7 12,290 10,900 10,710 7,720 13 16, ... 670 13,785 7,720 4 5,020 5,200 7,630 9 15,015 11,835 15,125 8,465 15 20, ... 600 20,630 8,465 5 8,965 8,090 12,595 11 19, ...

SYSTEMS Sill Plate Anchor Solutions 31 x 6 THD50600H 2 2x or 3x x 6 THD62612H ... HD Model No. Sill Plate Size (in.) x 6 THD62600H 2 2x 8 10 Minimum End ... Distance 10 x 8 THD50800H 2 Double 2x 8 1 1 ... www.strongtie.com/info. 3. Designs based on a minimum emdedment of 3 for Titen ... . 5. Direct 1 to 1 replacement is based on parallel-to-plate, perpendicular-to ... anchor bolt of equivalent diameter. 6. For concrete foundation only, 6" ... 7. Minimum edge and end distances are based on distance from edge of concrete to ... /info. 3. Direct 1 to 1 replacement is based on parallel-to-plate, perpendicular-to- ... . 5. Minimum edge and end distances are based on distance from edge of concrete to ... (mm) 0.145 (3.7) (7.9) 18 (457) 24 (610) 36 (914) Interior Braced Walls 3 ...

-16d Sinkers 1085 1305 0.107 LTT20B 6 12 3 2 19 1 10-16d 2 1675 1750 0. ... 24-16d 4 4140 4455 0 2, 40, 82, 121 6, 40, 82 30, 99, 122 40, 97, 99, 122 40, ... . C L 1. Allowable loads for HTT are based on the lower of the 2001 NDS fastener ... by 2.5. 2. 16d sinkers (0.148" dia. x 3 long) or 10d commons may be ... durations govern. 5. Bolt values are based on a minimum lumber thickness of 1 ". 6 ... plate will achieve the table loads. 8. Post design shall be by Designer. 9. NAILS: ... 16d 0.162" dia. x 3 long, 10dx1 0.148" dia. x 1 long, ... 16d sinker 0.148" dia. x 3 long. See page 16-17 for other nail ... 2-2x4 or 4x4), except LTT19). Bolt the base to the wall or foundation with a ...

16d commons. Reduce the allowable load based on the size and quantity of fasteners ... attached to the shearwall studs or post may be required by the Designer for ... are calculated using a 4" slab over 6" and 8" foundation walls. PAHD42, ... Embed. Depth le Nails Code Ref. PAHD42 6 6 " 12-16d 8 16-16d HPAHD22 6 10" 16- ... 16d 8 23-16d PAHD42 6 6 " 12-16d 8 12-16d HPAHD22 6 10" 16-16d ... 8 19-16d HPAHD22-2P 6 14 " 16-16d 20, 124 20, 124 8 23-16d ... . 1.Loads have been increased 33% and 60% for earthquake or wind loading with no ... other loads govern. 2.16d sinkers (9 ga x 3 or 10d commons may be substituted for ... may be embedded 4" into the slab and 6" into the 8" stemwall beneath for a ...

46 Caps Bases AB/ABA/ABE/ABU Adjustable and Standoff ... Post Bases Model No. Nominal Post Size Material Dimensions Fasteners ... Allowable Loads (DF/SP) Base (Ga) Strap (Ga) W L H HB 6 Anch. Dia ... Post Uplift (133) Uplift (160) Down (100) ... Bolts Qty Dia ABA44 4x4 16 16 3 3 6-10d 555 555 6000 5, 41, 121 5, 41, 121 6 ... 8, 36, 91, 127 ABE44 4x4 16 16 3 3 6-10d 520 520 6665 ABU44 4x4 16 12 3 3 ... 1 12-16d 2 2200 1800 2200 2160 6665 ABA44R RGH 4x4 16 16 4 3 6-10d 555 ... 555 8000 ABE44R RGH 4x4 16 16 4 3 6-10d 400 400 6665 ABE46 4x6 12 16 3 5 ... 4 5 8-16d 700 700 12000 ABA66 6x6 14 14 5 5 8-16d 720 720 10665 ...

47 Caps Bases EPB44T/EPB44PHDG Elevated Post Bases EPB Elevated Post Bases Model No ... Loads (DF/SP) Uplift (133/160) EPB44T 6-16d 1130 3275 Download (100) Anchor Bolt ... SET AT 1140 6, 121 170 EPB44PHDG 8-16d 1265 3670 985 ... limited by buckling capacity of the post. 5. NAILS: 16d 0.162" dia. x 3 long. See ... and washer (not supplied) U.S. Patent 5,666,774 Typical EPB44T Installed with SET ... limited by buckling capacity of the post. 5. NAILS: 16d 0.162" dia. x 3 long. See ... MATERIAL: EPB44A 14 ga.; others 12 ga. base plate, 1 OD x 8" pipe FINISH: EPB44A ... HDG); see Corrosion- Resistance, page 6-7. INSTALLATION: Use all specified ... above concrete, 2" for EPB44A. Post bases do not provide adequate resistance to ...

48 Caps Bases PB/PBS Regular and Standoff Post Bases ... 5 3 1365 765 1325 7, 90, 121 7, 62, 90, 121 PB66 5 5 1640 765 1325 ... 1640 PB66R 6 5 1640 765 1325 1640 Code Ref. The ... It reduces the potential for decay at post and column ends. MATERIAL: PB 12 gauge ... or HDG; see Corrosion-Resistance, page 6-7. INSTALLATION: Use all specified ... fasteners. See General Notes. Post bases do not provide adequate resistance to ... members from rotating about the base and therefore are not recommended for ... up to the bottom of the 1" standoff base plate. A 2" minimum side cover is ... PBS44A Installation Model No. Nominal Post Size Material Dimensions Fasteners ... Allowable Loads (DF/SP) Base (Ga) Strap (Ga) W L H HB Anch. Dia Post ...

49 Caps Bases CBSQ Column Bases This product is preferable to similar ... of these features. CBQ Column Bases Model No. Nominal Column Size Material ... Dimensions Number of Simpson SDS x 2" Screws Allowable Loads Base (Ga) ... Strap (Ga x Width) W1 W2 D H Uplift (133) Uplift ( ... 160) Down (100) CBSQ44-SDS2 4x4 12 10ga x 2 3 3 7 8 14 5335 5335 10975 ... CBSQ46-SDS2 4x6 12 10ga x 3 3 5 7 8 14 5335 5335 14420 CBSQ66 ... -SDS2 6x6 12 10ga x 3 5 5 6 8 14 5710 6855 14420 Code Ref. 46, ... 107, 124 CBSQ-SDS2 U.S. Patent 4,924,648 Typical CBSQ-SDS2 Installation 1. For ... before installing CBSQ into concrete. Base download on column or concrete, ... Dimensions Number of Simpson SDS x 2" Screws Allowable Loads Base (Ga) ...

50 Caps Bases LCB/CB Column Bases Model No. Nominal Column Size Material ... Dimensions Column Fasteners Strap Base (Ga) W1 W2 D Nails Nails Bolts Qty Dia ... 133) (160) (133) (160) LCB44 4x4 12 ga x 2 16 3 3 6 12-16d 2255 2705 3545 ... 4250 CB44 4x4 7 ga x 2 7 3 3 8 4200 4200 LCB46 4x6 12 ga ... x 2 16 3 5 6 12-16d 2255 2705 3530 4240 2, 40, 121 ... 121 2, 40, 121 2, 40, 121 CB46 4x6 7 ga x 2 7 3 5 8 4200 4200 CB48 4x8 7 ga x ... 2 7 3 7 8 4200 4200 CB5-4.5 CB7-6 CB7-7.5 CB7-9 CB7-10.5 CB9-6 CB9-7.5 ... CB9-9 CB9-10.5 CB5-6 GLULAM 7 ga x 3 7 5 4 6 6 9 8 4200 4200 GLULAM ... 7 ga x 3 7 5 8 4200 4200 LCB66 6x6 12 ga x 2 16 5 5 5 12-16d 2255 2705 ...

51 Caps Bases BC/BCS Post Caps LCC Lally Column Caps Model No. ... 160) 1 W1 W2 L1 L2 H1 H2 Beam Surface Post Surface Post Top Surface Uplift Lateral ... 3-16d 980 1000 BC46 3 5 4 2 3 2 6-16d 3-16d 980 1000 BC4R 4 4 4 4 3 3 ... 6-16d 6-16d 980 1000 BC6 5 5 4 4 3 3 6-16d ... 6-16d 1050 2000 4, 37, 87, 121 BC6R 6 6 6 6 3 3 6-16d 6-16d 1050 2000 BC8 7 ... 7 7 7 4 4 6-16d 6-16d 1800 2000 BCS2-2/4 3 3 2 2 2 2 4 ... -10d 3-10d 780 1025 BCS2-3/6 4 5 4 2 3 2 6-16d 3-16d 800 ... 1495 BASES BC40 3 3 2 3-16d 4-16d 535 BC40R ... 3 4-16d 4-16d 535 BC60 5 5 3 6-16d 4-16d 535 BC60R 6 6 3 6-16d ...

LPC AC 52 Caps Bases AC/LPC/LCE Post Caps PC/EPC Post Caps PC Typical PC ... Post Cap Installation Typical EPC End Post Cap Installation A custom connection ... for post-beam combinations at medium design loads. ... Z-MAX; see Corrosion-Resistance, page 6-7. INSTALLATION: Use all specified ... : For end conditions, specify EPC post caps, providing dimensions are in ... for Code Listing Key Chart. Model No. Post Size Dimensions Fasteners Each Side ... L2 L3 Surfaces Uplift PC/EPC Lateral 2 Post Beam PC Beam EPC (133) (160) PC (133/ ... 133/160) PC44-16 4x 4 3 3 2 7 4-16d 6-16d 4-16d 1000 1000 925 1000 PC44 4x 4 3 ... 3 2 7 4-16d 6-16d 4-16d 1470 1700 925 1070 PC46-16 4x 6 ... 3 5 2 9 4-16d 6-16d 4-16d 1000 1000 925 1000 PC46 4x 6 3 ...

53 Caps Bases CCQ/ECCQ Column Caps This product is ... General Notes. Install Simpsons SDS x2 wood screws, which are provided with ... 16 24490 7145 5955 14 11 CCQ74SDS2.5 6 3 7 8 16 13230 5680 5680 14 11 ... 16 16405 7145 5955 14 11 CCQ76SDS2.5 6 5 7 8 16 20790 7245 6270 14 11 ... CCQ77SDS2.5 6 6 7 8 16 25515 7245 6270 14 11 CCQ78SDS2.5 6 7 7 8 16 28350 ... 7245 6270 14 11 CCQ46SDS2.5 3 5 7 8 8 16 ... 5955 14 11 CCQ3-4SDS2.5 3 3 7 8 6125 5680 5680 16 14 11 CCQ3-6SDS2.5 3 5 ... 3 8 10045 5680 5680 16 14 11 7 CCQ5-6SDS2.5 5 5 8 15785 7245 6270 16 14 11 7 ... CCQ5-8SDS2.5 5 7 8 21525 7245 6270 16 14 11 7 Uplift Down L Beam Post ...

55 Caps Bases ECC/ECCU Column Caps L ECC 3 3 7 6 ... 2 2 6125 3 5 7 6 2 2 9625 3 3 5 4 1 2 7655 3 5 8 ... 6 2 2 12030 5 3 9 8 2 2 10045 5 5 ... 5 7 9 8 2 2 21525 20, 80 5 3 7 6 2 12030 5 5 7 6 2 2 18905 5 7 9 ... 6 2 2 25780 5 7 9 6 2 2 24060 7 3 10 8 2 2 18375 7 5 ... 7 7 10 8 2 2 36750 4855 4855 4855 6 3 10 8 2 2 13230 6 5 10 8 2 2 ... 20790 6 6 10 8 2 2 25515 6 7 10 8 2 2 28350 7 5 10 8 2 2 ... 29260 Code Ref. 3 7 8 L ECCU 9 9 6 9 10 10 10 9 9 9 9 10 10 10 ... 3605 3605 2625 2625 4670 4670 3325 740 6 ECC3 -4 ECC3 -6 ECC44 ECC46 ECC5 -4 ... ECC5 -6 ECC5 -8 ECC64 ECC66 ECC68 ECC6-7 ECC7 ...

loads have been increased 33% and 60% for earthquake or wind loading with no ... other loads govern. 2.Load values are based on a minimum lumber thickness of 1 ". 3 ... each other. 5. NAILS: 10dx1 0.148" dia. x 1 long. See page 16-17 for other nail ... 3 3 MSTC48B3 MSTC66B3 11 9 Studs/ Post 1. Using fewer than 38 nails in the ... studs/post will reduce the capacity of the ... per nail for HF/SPF. 2. Nails in studs/post shall be installed symmetrically. Nails ... length of the strap over the studs/post. 3. The 3" wide beam may be double 2x ... by 2, or the calculated nail values. 6. NAILS: 16d 0.162" dia. x 3 long, 10d 0. ... 148" dia. x 3" long. See page 16-17 for other nail ...

loads have been increased 33% and 60% for earthquake or wind loading with no ... . 4.When attaching to concrete use 3- x1 Titens. 5.RBC installed over 1" ... Fir. For SPF, the load is 340 lb. 6. NAILS: 10dx1 0.148" dia. x 1 long. See ... Lateral (133/160) 1 45 to 90 440 6-10dx1 6-10dx1 6-10dx1 6-10dx1 3- "x2 ... Titen 6-10dx1 380 2 0 to 30 485 420 160 3 0 to ... Lateral Support IBC 2000/2003, 2308.10.6 Blocking UBC 1997, 2320.12.8 Blocking ... Allowable Loads 2 DF/SP W1 W2 L Base Post (133) (160) Bolts Nails Bolts Nails F1 ... 565 A33 3 3 4-10d 4-10d 2- 3- 330 625 330 750 A44 4-10d 4-10d 295 625 ... Z-MAX; see Corrosion-Resistance, page 6-7. INSTALLATION: Use all specified ...

Rigid Tie Connectors RTCH U.S. Patent 6,022,165 RTR The RTC series secures two wood ... forming a 90 corner to a vertical post. The RTC42 and RTC44 are heavy-duty ... structural connectors. Based on loads of 40 lbs per sq ft, a 10 x 10 ... joists and 4 RTC42s. See the table for Post and Joist sizes. The RTCH is hidden ... Z-MAX; see Corrosion-Resistance, page 6-7. INSTALLATION: Use all specified ... for Code Listing Key Chart. Model No. Post Size Joist Size Fasteners (Total) ... Allowable Downloads 1 Post Joist Floor (100) Roof (125) FWL2 2x ... 4-SD8x1.25 RTC22Z 2x 2x 5-SD8x1.25 6-SD8x1.25 RTCH 2x 2x 4-SD8x1.25 4-SD8x1.25 200 ... RTC42 4x4 2x 14-SD8x1.25 8-SD8x1.25 650 810 4x4 2x 14-16d Sinkers 8-10dx1 ...

OHS 7 2 12 4 1680 2015 OHS135 7 6 13 4 4205 5045 OHS195 7 6 19 8 ... 7 2 12 12 5 OT 12 2 12 12 6 OHT 7 2 2 2 2 2 3 4 3 4 12 ... 12 6 170 (100/133/ 160) (100/133/ 160) ... HEAVY ANGLES OHA33 7 3 3 2 OHA36 7 3 6 4 Code Ref. 180 2. Allowable loads ... are based on a minimum member thickness of 3 ". 3 ... loads have been increased 33% and 60% for earthquake or wind loading and ... nominal sawn beam allowable bearing at 625psi on seat area; reduce where shear value ... of beam, end bearing value of post, L/R of post, or other criteria are ... limiting. 3. Post sides are assumed to lie in the same ... OECC. Model No. Dimensions Bolts Beam Post Uplift Down Ga W2 L Qty Dia Code Ref. ... 3 5 12 4 3365 OCC88 3 7 15 4 6200 H 4 7 7 7 7 W1 3 3 5 5 7 1465 ...

W L Qty Dia Code Ref. HST2PC 7 2 21 6 4350 5220 HST5PC 7 5 21 12 ... 8875 10650 HST6PC 3 6 25 12 12890 3, 39, 88, 121 180 ... 15470 HST3PC 3 3 25 6 6400 7680 4155 4990 4190 5030 3900 4685 ... 7 2 18 4 PS418PC 7 4 18 4 PS720PC 7 6 20 8 1535 565 1535 565 2585 815 2585 ... 7 2 16 16 5 1212HTPC 7 2 12 12 6 1616HTPC 7 2 2 2 2 2 4 4 4 4 ... 16 16 6 170 (100/133/ 160) (100/133/ 160) 1. ... loads have been increased 33% and 60% for earthquake or wind loading with no ... loads govern. 2. Allowable loads are based on parallel-to-grain loading and a ... CB68PC 7 7 2 4200 CB88PC 3 7 2 6650 CB810PC 3 9 W1 3 3 5 3 5 7 7 2 ... 6650 Allowable Tension Loads (133/160) 1. ...

ARCHITECTURAL PRODUCTS GROUP STANDOFF BASES HL HEAVY ANGLES GUSSETS Typical PBV6PC ... 5x5 4 4 1 4-10d 4490 5865 CPS6 6x6 5 5 1 4-10d 4490 7745 CPS7 8x8 ... 7 7 1 4-10d 4490 8315 PBV6PC 6" Dia 5 1 4-SDS X3 " 3800 9250 PBV10PC ... 10" Dia 9 1 4-SDS X3 " 3800 19225 Post or Column Size L W H Post Dimensions ... load capacities are for solid sawn posts with specific gravity of 0.36 minimum ... except the PBV, which is based on round "Viga" (Ponderosa Pine) wood ... posts. 2. All allowable uplift loads are based ... . 3. Download capacities are calculated based on the standoff bearing area and a ... of 2500 psi except the PBV, which is based on the wood bearing strength (700 psi ... term loading. 5. NAILS: 10d 0.148" dia. x 3" long. See page 16-17 for other nail ...