Catalog: Wood Construction Connectors 2006 Catalog
Company/Brand: Simpson Strong-Tie
adjustable top flange hanger in Wood Construction Connectors 2006 Catalog by Simpson Strong-Tie
26, 27 Girder Hangers ... 62-67 SOLID SAWN CONNECTORS Adjustable Hangers ......................... .... 82, 83 ... 186 Face Mount Hangers ......................... ... 68-76 ... Rough Lumber Face Mount Hangers ........ 76 Sloped/Skewed Connectors ... ................ 82, 86 Top Flange Hangers ......................... .... 77-81 ... STRUCTURAL COMPOSITE LUMBER CONNECTORS Adjustable Hangers ......................... 114, ... 186 Face Mount Hangers ......................... ... 90-96 ... Skewed Connectors ............ 114, 117 Top Flange Hangers ... 186 Face Mount Hangers ....................... 119, 120 Hinge ... 161 Top Flange Hangers ......................... 121-123 ... PLATED TRUSS CONNECTORS Adjustable Hangers ......................... 125, 131 ...

PSL 750 psi 0.50 f. For face-mount hangers straight straps, use 0.86 of table ... post-installation tightening. l. Top flange hangers may cause unevenness. Possible ... and include using a face mount hanger, and routering the beam or cutting the ... subfloor to accommodate the top flange thickness. m. Built-up lumber (multiple ... . Contact factory for details. p. Hanger Options (page 188) some combinations of ... hanger options are not available. In some ... in the tables, unless otherwise noted. Hanger configurations, height, and fastener ... table load for the non-modified hanger, and adjust as indicated. Gauge may ... manufacturing process used. U and W hangers normally have single stirrups; ... . B, GLT, HGLT, HW, LBV, W and WNP hangers for sloped seat installations are ...
specified fasteners, and develop the top flange bearing length. h. Some catalog ... . l. Simpson recommends that hanger height be at least 60% of joist height ...
83 Solid Sawn Connectors VPA Adjustable Variable Pitch Connectors HCP Hip ... connects a rafter or joist to double top plates at a 45 angle. MATERIAL: 18 ... General Notes. Attach HCP to double top plates; birdsmouth not required for ... . Check with factory. The VPA is adjustable to slopes between 3:12 and 12:12, ... is required when using the VPA. This hanger reduces the need for beveled plates ... to prevent splitting. STEP 1 Install top nails and face PAN nails in A flange to ... outside wall top plate. STEP 2 Seat rafter with a hammer ... , adjusting B flange to the required pitch. STEP 3 Install ... B flange nails in the obround nail holes, ... VPA2 U.S. Patent 5,335,469 A and B flanges touch at 45 HCP2 (HCP4Z similar) U.S. ...

HRC Hip Ridge Connectors PF Post Frame Hangers PFD26 (PFD24, PFDS26,PFD26L similar) U. ... Patent 5,104,252 PFD and PFA post frame hangers have double shear nailing to speed ... installation. Diamond holes allow easy hanger alignment and attachment. MATERIAL: 20 ... . Diamond holes on PFD allow optional top flange nailing. Double shear nailing ... for greater strength. OPTIONS: These hangers cannot be modified. CODES: See page 12 ... and HRC42 to secure the HRC. Bend face flanges on HRC22 back flush with ridge, and ...

85 Solid Sawn Connectors THA/THAC Adjustable Truss Hangers This product is ... nailing and can be field-formed to give top flange hanger convenience. Designed ... degrees. Straps can be formed to give top flange hanger convenience. PAN nailing ... a minimum of 2 ". A minimum of four top and four face nails must be used. For ... the strap is field-formed over the top of the header a minimum of 1 for the ... for all others, and a minimum of four top and two face nails are used. CODES: ... 160) Floor (100) Snow (115) Roof (125) Top Face Straight Slant MINIMUM NAILING TOP ... FLANGE 2x4 18 1 9 5 4-10d 4-10d 4-10d ... except THA29) 4. THAR/L422 with 4-10d top nails and 2-10d face nails: When the ... hanger height is between 9" to 12", the ... with factory. Double Shear Nailing Top View Dome Double Shear Nailing Side ...

installed. No Web Stiffener Installed Hanger side flange supports joist top flange. ... Hangers provide some joist rotation resistance ... for deep joists. Web Stiffener Required Hanger side flange should be at least 60% of ... . Rotation Resistance If non-skewed hanger side flange is less than 60% of joist ... staggered A34 framing anchors above the hanger. No Web Stiffener Results in Rotation ... Hanger side flange is below the joist top flange. No web stiffener results in ...

Lumber Connectors IUS/IUT/MIU I-Joist Hangers The improved IUS is now fully ... compatible with shallow flange I-joists! I-joists with flange ... are not required! The IUS is a hybrid hanger that incorporates the advantages of the ... face mount and top mount hanger. Installation is fast with the Strong- ... -jigging locator tabs. The MIU series hangers are designed for commercial and high ... PAN), which minimizes splitting of the flanges while permitting time-saving nailing ... which nails into the I-joists bottom flange when web stiffeners are not used, or ... into the web stiffener. I-joist flange thickness for bend-tab application is 1 ... models have triangle holes in header flanges for Min/Max nailing) U.S. Patent 6,523, ... 5,555,694 Bend tab into the bottom flange and fasten with 10d x 1 nails at ...

I-Joist Structural Composite Lumber Hangers 1. The W dimension should be ordered ... Options Fasteners Allowable Loads Top Face Joist Uplift (133) Uplift (160) DF ... ply seam. Joist Dimensions Model No. Hanger Dimensions Width Depth W 1 H C 9 -14" 9 ... to give height adjustability and top flange hanger convenience. Positive angle ... splitting of the I-joists bottom flange. MATERIAL: THAI-2-14 gauge; all others- ... : Factory-order the THAI-2 for hanger width needed. See table for allowable ... for all I-joists used with these hangers. When a total of 20 face nails are used ... nailing configuration is shown for top nailing installations. The strap must ... be field-formed over the top of the header by a minimum of 2 ". ... to connect ripped 2x framing to the top of another wood joist. MATERIAL: 20 ...

connection, see page 116 The VPA is adjustable to slopes between 3:12 and 12:12, ... is required when using the VPA. This hanger reduces the need for beveled plates ... . VPA25 U.S. Patent 5,335,469 A and B flanges touch at 45 The HCP connects a rafter ... or joist to double top plates at a 45 angle. MATERIAL: 18 ... General Notes. Attach HCP to double top plates; birdsmouth not required for ... to limit splitting. STEP 1 Install top nails and face PAN nails in A flange to ... outside wall top plate. STEP 2 Seat rafter with a hammer ... , adjusting B flange to the required pitch. STEP 3 Install ... B flange nails in the obround nail holes, ...

Hip Ridge Connectors For complementary top plate connection, see page 115 SUR/SUL/ ... HSUR/HSUL Skewed 45 Hangers for I-Joist and SCL HSUR SUL2.56/11 ... holes to secure the HRC. Bend face flanges back flush with ridge, and complete ... , 4.75 and 5.12 are improved 45 skewed hangers designed specifically to ease the ... to Positive Angle Nailing these hangers encapsulate the top flange of the I- ... . The full range of 45 skewed hangers feature obround nail holes on the acute ... Where noted,triangle holes in the joist flange may be filled for additional uplift ... (see Footnote 3). OPTIONS: These hangers will accommodate a 40 to 50 skew. ... Available with the A2 flange turned in on 2-2x and 4x models only ( ...

125 Plated Truss Connectors THA/THAC Adjustable Truss Hangers This product is ... 160) Floor (100) Snow (115) Roof (125) Top Face Straight Slant MINIMUM NAILING ... TOP FLANGE 2x4 THA29 18 1 9 5 4-10d 4-10d 4- ... Nailing Installation 5. For single 4x2 top chord carrying members, THA 4x hangers ... of the table value. Loads are based on hanger installations at panel points. 6. ... nailing and can be field-formed to give top flange hanger convenience. MATERIAL: ... a minimum of 2 ". A minimum of four top and four face nails must be used. For ... the strap is field-formed over the top of the header a minimum of 1 for the ... " for all others, and a minimum of four top and two face nails are used. OPTIONS: ... THA hangers available with the header flanges turned in for 3 (except THA413) and ...

Truss Connectors THAR/L422 Skewed Truss Hangers Typical THASL218 Installation (L in ... (100) Snow (115) Roof Code Ref. (125) Top Face Straight FACTORY SKEW 45 O 2x ... carried member into the seat of the hanger. Secure with 4-10dx1 nails. STEP 3 ... Adjust acute side of hanger to the desired angle. STEP 4 Adjust ... obtuse side of hanger flush with the carrying member. ... of 45 degrees. Straps must be bent for top flange installation. PAN nailing helps ... : Maximum Nailing A minimum of four top and 12 face nails must be used. Straps ... . Minimum Nailing A minimum of four top and 2 face nails must be used. Straps ... installed on 4x2 wood truss. THAL422 Top Face Straight Slant Snow (115) Roof ... those in the roof column. 3. Where the top of the carried member is flush with the ... top of the carrying member, H eff is equal ...