Catalog: Wood Construction Connectors 2006 Catalog
Company/Brand: Simpson Strong-Tie
|
| | .5 Girder Truss Tiedown The HDU series of holdowns are the latest in a long ... series of innovations from Simpson. These ... holdowns combine the advantages of low deflection and high capacity from ... pre-deflected geometry with the ease of installation of Simpsons patented SDS ... screws. Page 35 HDU Holdown The ICFVL Ledger ... is engineered to solve the challenges of mounting wood or steel ledgers to ... ICF) walls. Simpsons new ICF component of the system, the ICFVL, is designed to ... floors to lower floors from the inside of the wall. The convenient obround holes ... and through the floor system with a all thread rod, a nut and washer (not included). ... ply girder trusses with over 3,500 lbs. of uplift. It does not require attachment ... to the top of the truss, allowing installation after ...
|
| | 20 Fasteners Quik Drive SCREWS The SDS Strong-Driver has a deep socket ... a positive installation for the SDS Screws. Fits a standard drill. The Simpson ... Strong-Drive wood screw has a hex washer head for easy driving ... on the type and moisture content of wood. Use drill bit. WARNING: Industry ... Code Listing Key Chart. Model No. Wood Screw Description (Metric Equivalent) (mm) ... 6,109,850 Identification on all SDS screw heads (SDS x3 shown) unless ... the Code Report Agencies. 10. The SDS screws with HDG finish will be supplied with ... based on NDS calculation for a #14 wood screw or tested ultimate/5. If thread ... into main member is less than thread length T as shown in table, reduce ... allowable load by 172 lbs. x inches of thread not in main member. Use 121 lbs./inch ...
|
| | increases as tension is applied. The threaded stud version is available in nine ... available for wire supported fixtures. Threaded studs are set by tightening the nut. ... -wire anchors are set with the claw end of a hammer. CODES: ICC ER-1056 (Titen HD ... ); ER-3631 (Wedge-All); City of L.A. RR24682; FL 2304.2 (Titen HD); FL ... non-shrink anchor grouting material. ET offers an economical solution for general ... anchoring applications. Resin and hardener are dispensed and ... material. SET is ideal for high load applications where strength is the main concern. ... . Formulated for use in all types of weather, AT is designed to dispense ... Titen HD is a patented, high-strength screw anchor for concrete and masonry. The ... , non-expansion characteristics of the Titen HD makes it the ideal anchor ...
|
| | Design Load Flush W H B Anchor Dia. No. of Simpson SDS x3 Wood Screws PHD2-SDS3 14 ... on wood studs, limited by the lowest of 0.125" deflection, test ultimate ... divided by 3, or the wood screw value. 5.Deflection at Highest ... Allowable Design Load: The deflection of a holdown measured between the anchor ... bolt and the strap portion of the holdown when loaded to the highest ... test conducted on a wood jig. 6. SDS screws install best with a low speed right ... flush , touching sill plate) SDS x3 Screw US Patent No. 6,109,850 See screw info ... on page 20 7. SDS x3 screws are required for PHDs and HDQ8s. See T- ... HDLA for loads using shorter screws. 8. When using structural composite ... lumber columns, screws must be applied to the wide face of ... or HDQ8 are installed on both sides of the wood member provided either the ...
|
| | The HUC is a concealed flange version of the HU. Concealed flange hangers have ... W dimension is 2 or greater, at 100% of the table load. Specify HUC. HU is ... the W dimension is less than 2 at 100% of the table load. For allowable loads on ... CMU walls using x 2 hex head Titen screws or for concrete walls using x1 Titen ... screws. Titen screws are not provided. Drill the diameter ... or eliminate the mechanical interlock of the threads with the base material and ... that a minimum end and edge distance of 1 is maintained. Not recommended for ... exposed external applications. CODES: See page 12 for Code Listing Key ... same loads. 5. See page 147 for Titen screw information. 6. Loads for the HSUL/R ... be 0.8 the table loads for concrete applications. 7. Table allowable loads were ...
|