Catalog: Wood Construction Connectors 2006 Catalog
Company/Brand: Simpson Strong-Tie
|
| | Spacer ..............141 TSS Truss Seat..................150 TWB Wall Bracing .............181 U ... Hanger................... 26, 193 GLB Beam Seat ...................28 GLBT Beam ... Seat .................28 GLS Hanger ... Hanger ......................121 HGLB Beam Seat .................28 HGLS Hanger ...
|
| | ......................... ......... 22 Beam Seats ... 150, 151 Truss Seats ......................... ............ ... 97-113 GLULAM BEAM CONNECTORS Concealed Joist Tie ... 175-177 Floor Beam Leveler ...
|
| | a face mount hanger, and routering the beam or cutting the subfloor to accommodate ... single stirrups; occasionally, the seat may be welded. B, GLT, HGLT, HW, LBV, W ... and WNP hangers for sloped seat installations are assumed backed. To ... calculate the net height for a sloped seat. The customer must provide the H1 joist ... shall bear completely on the connector seat, and the gap between the joist end and ...
|
| | in masonry or concrete are limiting. 4. Beams must fully bear on base plate. 5. The ... bearing load values. 28 GLB/HGLB/GLBT Beam Seats Concrete Connectors ...
|
| | 5250 5260 4455 2150 4455 2725 Seat Thickness Code Ref. C L 1. Allowable ... , add a standard cut washer to the seat. No additional washer is required for a ... tie no rivets, and a 4-ply formed seat which wont unfold during loading. No ... portion to the top or side of purlin or beam (minimum 4x width (2-2x4 or 4x4), ...
|
| | CC88 CC96 CC98 CC106 CC48 Model No. Beam Width Dimensions Fasteners Allowable ... Loads W1 W2 H1 Beam Post Uplift Down Qty Dia Qty Dia (100 ... lie in the same vertical plane as the beam sides. 2. Loads may not be increased ... govern. Uplift loads are limited by the beam shear capacity per 2001 NDS except ... do not apply to splice conditions. 7. Beam depth must be greater than H1. Optional ... back-to-back welding to create a cross beam connector. Use the table loads; the ... column width in the direction of the beam width must be the same as the beam ... and H3 6 is a CC66 column cap with 5 beams on each side with all beam seats flush ...
|
| | ECC96 ECC98 ECC106 ECC48 Model No. Beam Width Dimensions Fasteners Allowable ... Loads W1 W2 H1 Beam Post Uplift ECCU Down ECC/ECCU Qty Dia ... lie in the same vertical plane as the beam sides. 2. Loads may not be increased ... 90 ECCU (ECCU44 has only 2 bolts to beam) For more information, request Form T- ... column width in the direction of the beam width must be the same as the beam ... 7 is an ECC66 end column cap with a 4x beam on the right side (specify direction ... left is shown) for stirrup) and stirrup seat 1" below the cap seat. CODES: See page ... govern. Uplift loads are limited by the beam shear capacity per 2001 NDS. 5. ECC ... W1 x W2. 6. Uplift loads assume minimum beam height of 11". Beam shear must be ... load cannot be greater than listed. 7. Beam depth must be greater than H1. ...
|
| | tested for installation at the end of a beam or on a post, they provide a strong ... Chart. Typical HUCQ Installation on a Beam Typical HUCQ Installation on a Post ... concealed flange) models. HU only rough beam sizes available by special order. See ... . Consult factory. HU214 Projection seat on most models for maximum bearing and ...
|
| | FLANGE HANGERS JB/LB/BA/B/HHB Joist, Beam and Purlin Hangers HUTF/HUSTF Heavy ... TABLE This table also applies to sloped-seat hangers. B SERIES WITH VARIOUS HEADER ... into the joist. OPTIONS: HUTF Rough beam sizes are available by special order. ... . Production models have projected seats. Square cut seats may be ordered. ...
|
| | attached to the top of a steel I-beam, concrete or masonry wall. This table ... also applies to sloped-seat hangers. Installation on Wood Nailer ...
|
| | (optional); optional diamond hole in seat allows attachment of hanger to I-joist ... on a 3x Nailer mounted on a Steel Beam This product is preferable to similar ...
|
| | Nailing BA installed 2X nailer on steel beam minimum nailing Model Series Fasteners ... attached to the top of a steel I-beam, concrete or masonry wall. This table ... also applies to sloped-seat hangers. 1. Based on an additional ...
|
| | attached to the top of a steel I-beam, concrete or masonry wall. This table ... also applies to sloped-seat hangers. HW/HWI (HWU similar) Correct ...
|
| | 119 Glulam Beam Connectors FACE MOUNT HANGERS HU/HGUS ... Glulam Beam Double Shear Joist Hangers Carried ... for Code Listing Key Chart. Projection seat on most models for maximum bearing and ...
|
| | attached to the top of a steel I-beam, concrete or masonry wall. This table ... also applies to sloped-seat hangers. Typical HHB, GB and HGB Saddle ... Hanger Options, page 188. 121 Glulam Beam Connectors TOP FLANGE HANGERS HHB/GB/ ... HGB Beam Purlin Hangers ...
|
| | bolts in slots away from bearing seat to allow for wood shrinkage. OPTIONS: ... . Specify the H dimension. For dapped beams, reduce the H dimension by the PT ... ) L H 3 Min H Max Rotation Bolts Per Beam Slotted Tension Bolts Allowable ... . Typical HC4C3TA Installation with Beam Top Dapped HC2CTA HCCTA HCA HCC3TA HC3A ... ) Dimensions Two Rotation Bolts Per Beam Three Rotation Bolts Per Beam 4 PT W ... 8 8 10 10 10 10 3 3 Code Ref. Beam Width Bolt Dia. 23, 94, 126 23, 94 ... TABLE Alternate Installation with Beam Top Non-Dapped 124 Glulam Beam ...
|
| | attached to the top of a steel I-beam, concrete or masonry wall. This table ... also applies to sloped-seat hangers. Model No. Ga Dimensions ...
|
| | STEP 1 Install carried member into the seat of the hanger. Secure with 4-10dx1 ... . Designed for 4x2 floor trusses and 4x beams, the new THAR/L422 has a standard skew ... measured from the top of the bearing seat to the top of the carrying member. 4. ...
|
| | -16 gauge; HETAL-strap 16 gauge, truss seat 18 gauge; META-18 gauge; TSS-22 gauge ... HHETA are embedded 4" into a concrete beam or grouted block wall; HETAL is ... nails must be installed into the truss seat of the HETAL. 3.Parallel-to-plate load ... /TSS Embedded Truss Anchors and Truss Seat Snap-In ...
|
| | /TSS Embedded Truss Anchors and Truss Seat Snap-In 1. For concrete tie beam ... Installation Into Grouted CMU Bond Beam Uplift (133) Uplift (160) Code Ref. ...
|
| | 3. OT, OHT loads assume a continuous beam. 1. OL, OHL, OT and OHT must be ... loading and apply only to continuous beams; reduce for other loading conditions in ... are determined by nominal sawn beam allowable bearing at 625psi on seat ... area; reduce where shear value of beam, end bearing value of post, L/R of post ... lie in the same vertical plane as the beam sides. 4. For end conditions specify ... OECC. Model No. Dimensions Bolts Beam Post Uplift Down Ga W2 L Qty Dia Code ... those in the roof column. 3. Glulam beam sizes are available. Add an X to the ...
|
| | loads govern. 2. See page 50 for glulam beam sizes. Add PC to the model, i.e. CB5- ... information on these products. BEAM HANGERS MATERIAL: Top flange-7 ga, ... -7 ga. Model No. Dimensions Bolts Beam Post Uplift Down Ga W2 L Qty Dia Code ... lie in the same vertical plane as the beam sides. 3. Downloads are determined ... Fc perpendicular equal to 625 psi on seat area; reduce where end bearing value ... . 4. See pages 54 and 55 for glulam beam sizes and end conditions. Add PC to the ... , 1616HT loads assume a continuous beam ...
|
| | Flanges) Typical HUC Installed on a Beam Typical HUTF Sloped Down Installation ... General Notes. SLOPED AND/OR SKEWED SEAT HUTF can be skewed to a maximum of 45 ... of the table load. SLOPED AND/OR SKEWED SEAT WM/WMI may be skewed and/or sloped to ...
|
| | . INSTALLATION: Bevel-cut the carried beam for skewed hangers. HANGER HEIGHT For ... table roof load. SLOPED AND/OR SKEWED SEAT GLT/GLTV/HGLT/HGLTV and GLS/HGLS ... with or without a sloped and/or skewed seat (see illustration). Reduce allowable ... at the end of a header. Minimum seat width 3 ". The maximum allowable load ... Hanger Options General Notes. SKEWED SEAT GH hangers may be skewed to a maximum ... Options General Notes. SLOPED OR SKEWED SEAT, 45 MAXIMUM The maximum allowable down ...
|