Catalog: Wood Construction Connectors 2006 Catalog
Company/Brand: Simpson Strong-Tie
|
| | Tie .......................18 2 CB Column Base..........50, 185 CBQ Column Base ... ...............49 CBSQ Column Base .............49 CC Column Cap ... ...........54, 185 CCQ Column Cap.................53 CF-R Form Angle ... Roof Truss Clip. .........144 ECC, ECCU Column Cap......55 ECCQ Column Cap ... 23 LBV Hangers 100, 104-113, 192 LCB Column Base................50 LCC Lally Column ... Ties/Angles...........184 OCB, OCC Caps/Bases.......184 OHU Hangers.................. ...186 OU ...
|
| | Ties ................ 162-164 CAPS BASES Post/Column Caps and Bases ...
|
| | When using structural composite lumber columns screws must be applied to the wide face ... of the column. 5. Post design shall be by Designer. 6 ... When using structural composite lumber columns, screws must be applied to the wide face ... of the column. HDU U.S. Patent 5,979,130 Vertical HDU ...
|
| | When using structural composite lumber columns, screws must be applied to the wide ... face of the column. 9. Tabulated loads may be doubled when ...
|
| | When using structural composite lumber columns, screws must be applied to the wide face ... of the column. 7. Post design shall be by Designer. 8 ... When using structural composite lumber columns, screws must be applied to the wide ... face of the column. 9. Post design shall be by Designer. ...
|
| | When using structural composite lumber columns, bolts must be applied to the wide face ... of the column. 11. The Designer shall reduce the ...
|
| | 46 Caps Bases AB/ABA/ABE/ABU Adjustable and Standoff ... Post Bases Model No. Nominal Post Size Material ... into concrete. Base download on column or concrete, according to the code. 6 ... and finished hardware appearance. Post Bases provide tested capacity. They feature 1 ... the potential for decay at post and column ends. MATERIAL: AB 12 ga plates; 16 ga ... fasteners. See General Notes. Post bases do not provide adequate resistance to ... sizes similar) Additional standoff bases are on page 187. Anchor Bolt per ...
|
| | 48 Caps Bases PB/PBS Regular and Standoff Post Bases ... the potential for decay at post and column ends. MATERIAL: PB 12 gauge; PBS see ... fasteners. See General Notes. Post bases do not provide adequate resistance to ... into concrete. Base download on column or concrete, according to the code. 5. ...
|
| | 49 Caps Bases CBSQ Column Bases This product is preferable to similar ... or a combination of these features. CBQ Column Bases Model No. Nominal Column Size ... CBSQ into concrete. Base download on column or concrete, according to the code. 2. ... When using structural composite lumber columns, screws must be applied to the wide face ... of the column. 3.Downloads shall be reduced where ... limited by buckling capacity of the column. 3" min. side cover Model No. Nominal ... Column Size Material Dimensions Number of ... a greater net section area of the column compared to bolts. MATERIAL: See table ... screws, which are provided with the column base. (Lag screws will not achieve the ... same load.) Post bases do not provide adequate resistance to ... a greater net section area of the column compared to bolts. MATERIAL: See table ...
|
| | 50 Caps Bases LCB/CB Column Bases Model No. Nominal Column Size Material ... Dimensions Column Fasteners Strap Base (Ga) W1 W2 D Nails ... base plate flush with concrete. Post bases do not provide adequate resistance to ... .When using structural composite lumber columns, screws must be applied to the wide face ... of the column. 5. NAILS: 16d 0.162" dia. x 3 long. See ... . CB9 (CB5, CB7 similar) for Glulam Column Available with additional corrosion ...
|
| | 51 Caps Bases BC/BCS Post Caps LCC Lally Column Caps ... 5 4 2 3 2 6-16d 3-16d 800 1495 BASES BC40 3 3 2 3-16d 4-16d 535 BC40R ... BCS Installation BC4 Cap/Base Lally column caps provide adequate bearing length ... . See General Notes. Fit the lally column cap over the lally column and attach to ... Chart. Model No. W Girder Nails Lally Column Outside Dia. Allowable Loads Download ... a 3 ply LVL and a 3 "diameter steel column 1. Loads may not be increased for short ... DF and 700 for LVL/PSL, or the 8 lally column capacity. 3. Loads are for a continuous ... members by means other than the lally column. The splice condition load is 6750 lbs ... loads, LCC pipe must be welded to the column with an fillet weld around the entire ... or 16dx2 joist hanger nails. Post bases do not provide adequate resistance to ...
|
| | 53 Caps Bases CCQ/ECCQ Column Caps This product is preferable to ... a greater net section area of the column compared to bolts. The SDS screws ... screws, which are provided with the column cap. (Lag screws will not achieve the ... apply to CCOQ and ECCOQ. CCOQ and ECCOQ column cap only (no straps) may be ordered for ... field-welding to pipe or other columns. No loads apply. Dimensions are same as ... bearing or buckling capacity of the column, or other criteria are limiting. 2. ... members by means other than the column cap. 3. Uplift loads do not apply to ... When using structural composite lumber columns, screws must be applied to the wide face ... of the column. 9. ECCQ uses 14-SDS screws into the ...
|
| | -effective alternatives for replacing column caps by using a combination of ... widths and heights Instead of the column cap, consider this connector ... combination. Instead of the column cap, consider this connector ... combination. 54 Caps Bases CC Column Caps CC L 3 3 11 6 4 2 3035 3640 ... bearing or buckling capacity of the column, or other criteria are limiting. 4. ... spliced members by means other than the column cap. 6. Uplift loads do not apply to ... W2 dimension may be specified with any column size given (note that the W2 dimension ... 90 is limited by the W1 dimension). Column caps with W1, L, H1, and hole schedules ... a drawing to ensure accuracy. CCO Column cap only (no straps) may be ordered for ... field-welding to pipe or other columns. No loads apply. CCO dimensions are the ...
|
| | 55 Caps Bases ECC/ECCU Column Caps L ECC 3 3 7 6 2 2 6125 3 5 ... bearing or buckling capacity of the column, or other criteria are limiting. ECC44 ... widths and heights Instead of the column cap, consider this connector ... W2 dimension may be specified with any column size given (note that the W2 dimension ... 90 is limited by the W1 dimension). Column caps with W1, L, H1, and hole schedules ... accuracy. Loads may not apply. ECCO Column cap only (no straps) may be ordered for ... field-welding to pipe or other columns. No loads apply. ECCO dimensions are the ... -ECCUP for ordering information. ECCL L Column Cap. 7 gauge stirrups may be welded to ... column cap sides. ECCL has no uplift loads. ... Column cap only (no straps) may be ordered for ... field-welding to pipe or other columns. No loads apply. Specify ECCOL and ...
|
| | , use the values found in the SPF column. 4. DF I-joists include flanges made ...
|
| | , use the values found in the SPF column. 9. DF I-joists include flanges made ...
|
| | , use the values found in the SPF column. 5.I-joist header with SPF flanges will ...
|
| | , use the values found in the SPF column. 6. NAILS: 16d 0.162" dia. x 3 long. See ...
|
| | 24060 37810 37810 54600 (100) (133) COLUMN CAPS 1. Load values allowed assume a ... they do not exceed those in the roof column. 3. Glulam beam sizes are available. Add ... 6650 Allowable Uplift Loads (133/160) COLUMN BASES 1. Uplift loads have been ...
|
| | . Add PC to the model, i.e. CB5-6PC COLUMN BASES INSTALLATION: Minimum side cover ... of base flush with concrete. Post bases do not provide adequate resistance to ... . Add PC to the model, i.e. CC3 -4PC. COLUMN CAPS INSTALLATION: Bolt holes shall be ...
|
| | ARCHITECTURAL PRODUCTS GROUP STANDOFF BASES HL HEAVY ANGLES GUSSETS Typical PBV6PC ... Dia 9 1 4-SDS X3 " 3800 19225 Post or Column Size L W H Post Dimensions Fasteners ...
|