13 results for embed found in 0.015 seconds

 

Catalog: Wood Construction Connectors 2006 Catalog
Company/Brand: Simpson Strong-Tie


 

Dia. (in) Drill Bit Dia. (in) Embed. Depth (in) 131 Code Ref. 1.These loads ...


 

. in. SET/ET Drill Bit Dia. in. Embed. Depth in. ET AT SET 1 1 1 1 1 1 ... are for concrete edge distance of 1 x embedment and spacing of 4 x embedment. 8. See ...


 

2x 1 RFB #5x8 5 2x 1 RFB Size Minimum Embed. Sill Plate Size (in.) Minimum Edge ...


 

6 2 9 Titen HD Diameter (in.) Minimum Embedment Depth (in.) Minimum Edge/End Distance ( ... (in.) 7 2 3 2 3 5 4 Minimum Embedment Depth (in.) Minimum Edge/End Distance ( ... (in.) 1775 4 8 2195 4 20 20 5 5 Embed. Depth (in.) SET AT NORMAL-WEIGHT ...


 

provides more concrete cover. Stamped embedment line aids installation. Configuration ... cold joint exists within the embedment depth between the slab and foundation ... 7 No. Stemwall Width Dia. Length Min Embed le Allowable Tension Load 1,2 Concrete ... 3x sill plates. 2. No cold joint within embedment depth unless provisions are made to ... diameter is the same. 4.Increase the embedment depth 2 to accommodate the HDC ... on the bolt head showing embedment angle and model. 33 Anchors SSTB ...


 

spall is 1" or less, measured from the embedment line to the bottom of the spall, full ... cold joint exists within the embedment depth between the slab and foundation ... center-to-center spacing is twice the embedment depth when resisting tension loads at ... be lower on the stud wall since the embedded portion of the holdown must be in the ... Rebar should be a minimum length of 2x embedment depth 12" (except corner installations ... to the form, resulting in 1" deeper embedment; see illustration. OPTIONS: See also ... Key Chart. Model No. Min Stem Wall Embed. Depth le Nails Code Ref. PAHD42 6 6 " ... 4875 5160 End Distance Model No. L Min. Embed. Depth Nails Allowable Uplift Loads (133 ... code to a maximum of 3685 lbs. Minimum embedment is 4"; 5" to the nearest edge. 1. ... HPAHD22 may be embedded 4" into the slab and 6" into the 8" ...


 

height. The threaded rod shall be embedded a minimum of 2 ". To adjust after the ... height. The threaded rod shall be embedded a minimum of 3 ". Minimum sidecover is ... and adjust to the desired height. Embedded in wet concrete: Embed rod minimum 4" ... embedment. Minimum sidecover is 3" from the ...


 

to obtain the full load. PBS: Embed into wet concrete up to the bottom of ...


 

be installed into the top flange and embedded into the grouted wall. Verify that the ... are for dressed timber widths. Embed WM into block with a minimum of one ...


 

-to-wood connectors can be directly embedded into a grouted block wall. It can also ... ITTM installed into grouted block wall: embed into block with a minimum of one course ...


 

be installed into the top flange and embedded into the grouted wall. Verify that the ... 12 and :12 use 85% of the table loads. Embed WM into block with a minimum of one ...


 

be installed into the top flange and embedded into the grouted wall. Verify that the ... fasteners specified in the table. Embed WM into block with a minimum of one ... Dia. (in) Drill Bit Dia. (in) Embed. Depth (in) 131 Code Ref. 1.These loads ... also apply to masonry. 1" embed. table loads apply to masonry ...


 

aligned at joint. Hammer the plate to embed the prongs. CODES: See page 12 for Code ...


 