Catalog: Wood Construction Connectors 2006 Catalog
Company/Brand: Simpson Strong-Tie
glulam beams connectors in Wood Construction Connectors 2006 Catalog by Simpson Strong-Tie
5 Wood Construction Connectors INTRODUCTION SIMPSONS QUALITY POLICY ... -20 Fasteners Quik Drive 21-28 Concrete Connectors 29-45 Anchors 46-55 Caps Bases 56-67 ... Shearwall 68-87 Solid Sawn Connectors 88-118 Engineered Wood Structural ... Composite Lumber Connectors 119-124 Glulam Beam Connectors 125-146 Plated Truss ... Connectors 147-154 Masonry Connectors 155-171 Straps Ties 172-182 ... wood-to-wood and wood-to-concrete connectors since 1956. Since then, Simpson Strong- ... largest manufacturer of construction connectors and to expand to include a complete ... listings. Largest number of patented connectors in the industry. European locations ... and manufacturing No Equal structural connectors and other related products that meet or ...

6 Wood Construction Connectors TABLE OF CONTENTS CORROSION INFORMATION ... 18, 19 CONCRETE CONNECTORS Anchor Adhesives ... 62-67 SOLID SAWN CONNECTORS Adjustable Hangers ... Mount Hangers ........ 76 Sloped/Skewed Connectors ................ 82, 86 Top Flange ... WOOD STRUCTURAL COMPOSITE LUMBER CONNECTORS Adjustable Hangers ... 118 Sloped/Skewed Connectors ............ 114, 117 Top Flange ... ......................... .. 97-113 GLULAM BEAM CONNECTORS Concealed Joist Tie ... ....................... 119, 120 Hinge Connectors............... ..................... 161 Top Flange ... 121-123 PLATED TRUSS CONNECTORS Adjustable Hangers ... 137, 138 MASONRY CONNECTORS Brick Ties ... 182 Hurricane Connectors ...................... 149-154 Straps ... 183 Deck Connectors ......................... ............ ...

14 Wood Construction Connectors IMPORTANT INFORMATION GENERAL NOTES a. ... Fir are the same as LVL, LSL, PSL, Glulams and Southern Pine, since the specific ... 425 psi 0.42 Hem Fir (HF) 405 psi 0.43 Glulam 560 psi 0.50 LVL (DF/SP) 750 psi 0.50 ... . Unless otherwise noted Simpson connectors cannot be welded. g. Pneumatic or ... nail tools may be used to install connectors, provided the correct quantity and type ...
PW PT Masonry @ 195 psi Wood F c on Glulam Width 5 3 6 8 10 HGLBA 3 to 9 5 10 ... in masonry or concrete are limiting. 4. Beams must fully bear on base plate. 5. The ... . 28 GLB/HGLB/GLBT Beam Seats Concrete Connectors ...
This product is preferable to similar connectors because of a) easier installation, b) ... using Fc^ equal to: 560 psi for glulam sizes and 625 psi for all others; ...
column caps by using a combination of connectors. Here are some examples. Designer must ... using Fc^ equal to: 560 psi for glulam sizes and CC86, CC88 and CC106; 750 psi ... and H3 6 is a CC66 column cap with 5 beams on each side with all beam seats flush ...
using Fc^ equal to: 560 psi for glulam sizes; 750 psi for 7 size; 625 psi for ... column caps by using a combination of connectors. Here are some examples. Designer must ...
119 Glulam Beam Connectors FACE MOUNT HANGERS HU/HGUS Glulam Beam ... 100) Snow (115) Roof Code Ref. (125) 3 GLULAM 3 GLULAM HU212-2 (Min) 14 3 10 2 2 ... HGUS3.25/12 3 10 4 56-16d 20-16d 5 GLULAM HU5.125/12 HU310-2 14 5 10 2 22-16d ... HGUS5.25/12 5 10 4 56-16d 20-16d 6 GLULAM HGUS6.88/10 12 6 8 4 46-16d 16-16d ... HGUS6.88/14 6 12 4 66-16d 22-16d 5 GLULAM 7 GLULAM See HHUS and HGUS in 7" ...
120 Glulam Beam Connectors LGU/MGU/HGU/HHGU High Capacity Girder ...
. See Hanger Options, page 188. 121 Glulam Beam Connectors TOP FLANGE HANGERS HHB/ ...
122 Glulam Beam Connectors TOP FLANGE HANGERS GLS/HGLS/GLT/HGLT ... Beam Glulam Saddle Hangers See table on page 123. ... structural requirements for timber and glulam beams. GLT top flange depth allows ... flanges allow easy installation of beams. GLS and HGLS are heavy glulam saddle ... TOP FLANGE HANGERS LEG/MEG/EG Beam Glulam Hangers GLST Installed with Glulam ... Beams (HGLST similar) When H dimension is ...
123 Glulam Beam Connectors TOP FLANGE HANGERS GLULAM BEAM Joist or ... H is 28 or less. 5. Allowable loads for glulam sizes are based on 560 psi wood bearing ...
. Specify the H dimension. For dapped beams, reduce the H dimension by the PT ... Horizontal loads are for Doug Fir-larch glulams minimum W 3 ". For other wood types, ... with Beam Top Non-Dapped 124 Glulam Beam Connectors HCA Hinge Connectors ...
loading and apply only to continuous beams; reduce for other loading conditions in ... not exceed those in the roof column. 3. Glulam beam sizes are available. Add an X to ...
other loads govern. 2. See page 50 for glulam beam sizes. Add PC to the model, i.e. ... minimum height listed in the table. 3. Glulam widths listed in table. To specify ... an X to the name and specify. 4. See Glulam Connectors section of this catalog for ... limiting. 4. See pages 54 and 55 for glulam beam sizes and end conditions. Add PC ...
4x12 10 8 12 6 3535 3990 3990 GLULAM BEAM CJT3 3 x7 5 4 6 1240 1240 ... not be noticeable and may reduce the connectors load carrying capacity. SDS x3 U.S. ...