Page 100 of 195 ![]() |
![]() View extracted text
Page 100 of Wood Construction Connectors 2006 Catalog by Simpson Strong-Tie101 Engineered Wood Structural Composite Lumber Connectors TOP FLANGE HANGERS W/WP/WPU/WM/WMU/HW/HWI/HWU I-Joist Structural Composite Lumber Hangers 2 " WP/WPI NAILER TABLE Model Nailer Top Flange Nailing Allowable Loads DF/SP SPF W 2x 2-10dx1 1600 1600 3x 2-16dx2 1765 1740 2-2x 2-10d 1665 1665 4x 2-10d 2200 2200 WP 2x 2-10dx1 2525 2500 3x 2-16dx2 3000 2510 2-2x 2-10d 3255 3255 4x 2-10d 3255 3255 HW/HWI 4x 4-16d 5285 HWU 2-2x 8-16dx2 5630 LSL 3375 Model Joist Fasteners Allowable Loads Header Type Width Depth Top Face Joist Uplift (133 160) DF/SP LVL 4 PSL LSL DF/SP SPF DF/SCL I-Joist 5 Code Ref. Masonry W 1 to 4 3 to 30 2-10dx1 2-10dx1 1635 1740 1600 1415 170 26, 83 170 26, 83 (widths greater than 2") 26, 124 (widths up to 3 ") 26 124 26, 83 1, 84 1 to 4 3 to 30 2-10d 2-10dx1 2150 2020 2200 1435 1 to 4 3 to 30 2-16d 2-10dx1 2335 1950 2335 1765 1435 WM 1 to 4 3 to 30 2-16d DPLX 2-10dx1 4175 WMU 1 to 7 9 to 28 6-10dx1 545 3380 1 to 7 9 to 28 2-16d DPLX 4- x1 Titens 4- x1 Titens 2- x1 Titens 6-10dx1 625 4175 1 to 7 3 to 30 3-10dx1 2-10dx1 2865 3250 2500 2000 2030 1 to 7 3 to 30 3-10d 2-10dx1 2525 3250 3650 3255 2525 1 to 7 3 to 30 3-16d 2-10dx1 3635 3320 3650 3255 2600 WPU 1 to 5 7 to 18 3-16d 4-16d 6-10dx1 775 4700 4880 3650 4165 4165 1 to 5 18 to 22 3-16d 4-16d 6-10dx1 485 4700 4880 3650 4165 4165 1 to 5 23 to 28 3-16d 4-16d 6-10dx1 315 4700 4880 3650 4165 4165 HW/HWI 1 to 7 3 to 32 4-10d 2-10dx1 3100 4000 5285 3100 1 to 7 3 to 32 4-16d 2-10dx1 5100 4000 4500 5285 3665 HWU 1 to 3 9 to 18 4-16d 4-16d 6-10dx1 810 6335 5500 5535 6335 5415 1 to 3 18 to 22 4-16d 4-16d 6-10dx1 765 6335 5500 5535 6335 5415 1 to 3 23 to 28 4-16d 4-16d 6-10dx1 635 6335 5500 5535 6335 5415 1 to 3 28 to 32 4-16d 4-16d 8-10dx1 1005 6335 5500 5535 6335 5415 4 to 7 9 to 18 4-16d 4-16d 6-10dx1 810 6000 5500 5535 6000 5415 4 to 7 18 to 22 4-16d 4-16d 6-10dx1 765 6000 5500 5535 6000 5415 4 to 7 23 to 28 4-16d 4-16d 6-10dx1 635 6000 5500 5535 6000 5415 4 to 7 28 to 32 4-16d 4-16d 8-10dx1 1005 6000 5500 5535 6000 5415 WP 1 to 4 3 to 30 2- x1 Titens 2-10dx1 3380 MID-WALL INSTALLATION 8 MID-WALL INSTALLATION 8 TOP OF WALL INSTALLATION TOP OF WALL INSTALLATION The table indicates the maximum allowable loads for W, WP and HW hangers used on wood nailers. Nailers are wood members attached to the top of a steel I-beam, concrete or masonry wall. This table also applies to sloped-seat hangers. HW/HWI (HWU similar) Correct Nailer Attachment 2 " 2 " W/WI 1. 16d sinkers (9 ga x 3²) may be used where 10d commons are called out with no load reduction. 2. Uplift loads are based on Doug Fir, and have been increased 33% and 60% for wind or earthquake loading; no further increase allowed. Divide by 1.33 and 1.60 for normal loading like cantilever construction. 3. SCL, structural composite lumber, is laminated veneer lumber, Parallam PSL and TimberStrand LSL. 4.Applies to LVL headers made primarily from Douglas Fir or Southern Pine. For LVL made primarily from Spruce Pine Fir or similar less dense veneers, use the values found in the SPF column. 5.I-joist header with SPF flanges will support 2030 lbs. 6. WP/WPI quantity of nail holes in top flange varies. 7. NAILS: 16d and 16d DPLX 0.162" dia. x 3 long, 10d 0.148" dia. x 3" long, 10dx1 0.148" dia. x 1 long. See page 16-17 for other nail sizes and information. 8. Mid-wall installation requires minimum of one grouted course above and below the hanger. Parallam and TimberStrand are registered trademarks of Trus Joist, a Weyerhaeuser company. Some model configurations may differ from those shown. Contact factory for details. W SERIES WITH VARIOUS HEADER APPLICATIONS WM/WMI (WMU similar) WPU Typical WM Installation with Alternate Nailing Pattern (ANP) The W, WP, WPU, HWU and HW series purlin hangers offer the greatest design flexibility and versatility. WMs are designed for use on standard 8" grouted masonry block wall construction. MATERIAL: See tables on pages 104 to 113; W, WI 12 ga. top flange and stirrup; WM, WMI, WMU 12 ga. top flange and stirrup; WPU, WP 7 ga. top flange, 12 ga. stirrup; HW, HWI 3 ga. top flange, 11 ga. stirrup; HWU 3 ga. top flange, 10 ga, stirrup. FINISH: Simpson gray paint; hot-dipped galvanized available: specify HDG. ALLOWABLE LOADS: For hanger heights exceeding the joist height, the allowable load is 0.50 of the table load. INSTALLATION: Use all specified fasteners. WM two 16d duplex nails must be installed into the top flange and embedded into the grouted wall. Verify that the header can take the required fasteners specified in the table. Hangers may be welded to steel headers with for W, WI, for WP, WPU WPI, and for HW, HWI, HWU by 1 fillet welds located at each end of the top flange, see page 14 for weld information. Weld-on applications produce maximum allowable load listed. Uplift loads do not apply to this application. Hangers can support multi-ply carried members; the individual members must be secured together to work as a single unit before installation into the hanger. Hangers can support joists sloped up to :12 using table loads. For joists sloping between :12 and :12 use 85% of the table loads. Embed WM into block with a minimum of one course above and one course below the top flange with one #5 vertical rebar minimum 24" long in each cell. Minimum grout strength is 2000 psi. Web stiffeners are required for standard joist nailing configuration with these hangers. OPTIONS: Specify alternate nailing pattern when web stiffeners are not being used (up to 16" in depth). Add X ANP after model number for nailing into the flange, available for 90 applications only. Uplift loads do not apply to this application. See Hanger Options, page 188 for hanger modifications and associated load reductions. CODES: See page 12 for Code Listing Key Chart.[close] |
Page 100 of 195 ![]() |
All copyrights remain by their owners. Who-sells-it.com is not an official partner of Simpson Strong-Tie. |