Page 102 of Wood Construction Connectors 2006 Catalog by Simpson Strong-Tie
103
Engineered Wood Structural Composite Lumber Connectors
LGU/MGU/HGU/HHGU High Capacity Girder Hangers
CSC Ceiling Support Clip /FSS Furring Stabilizer Strap
Provides 1" separation between the furring channel and joist to
allow for the use of Thermafiber insulation and the attachment of
the furring channel to all joists. Provides an efficient sound barrier,
and a one hour U.L. listed fire rating.
Field-form the FSS with the CSC to prevent furring channel
rotation during installation. Furring channel must match dimensions
shown to fit the CSC properly. U.L. listed. See Underwriters
Laboratories, Inc, Design No. L530 for USG and TJI
â
I-joists, and
No. L531 for USG and Willamette I-joists.
MATERIAL: 24 gauge (minimum).
FINISH: Galvanized
INSTALLATION: Use 1-8d x 1 nail.
Typical CSC and FSS Installation
Furring Channel
Detail
Thermafiber and TJI are
registered trademarks of
US Gypsum Company and
Trus Joist, a company of
Weyerhaeuser, respectively.
NEW! The GU hangers are a high-capacity girder
hangers designed for situations where the header and
joist are flush at top. This part can be used for retrofit on
the framing members after they are temporarily placed
in position. It uses Simpson Strong-Drive screws (SDS)
to make installation fast and easy, with no pre-drilling
required.
MATERIAL: See table.
FINISH: Galvanized.
INSTALLATION:
Use all specified fasteners. See General Notes.
Install with Simpsons SDS x2 screws, which
are provided with the GUs. (Note: lag screws
will not achieve the same loads.)
All multiple members must be fastened together to
act as a single unit.
Multiple member headers may require additional
fasteners at the hanger locations. The quantity
and location of the additional fasteners must be
determined by the Designer.
OPTIONS: Not available.
CODES: See page 12 for Code Listing Key Chart.
MGU
Typical MGU Installation
Ga
Model
No.
Fasteners
Dimensions
Min.
Header
Depth 3
ha
Allowable Loads
SPF/HF
DF/SP
Face
LGU3.62
10
16-SDS x2
MGU3.62
10
24-SDS x2
Joist
12-SDS x2
16-SDS x2
W
H 2
(min)
3
3
7
8
MGU5.50
10
24-SDS x2
16-SDS x2
5
8
Code
Ref.
Uplift 1
Download 3
Download 3
5380
6595
6595
HGU5.50
7
36-SDS x2
24-SDS x2
6440
9145
9145
14060
160
5
B
4
4
4
5
10
9895
HGU7.25
7
36-SDS x2
24-SDS x2
14060
7
5
10
9895
HHGU7.25
3
44-SDS x2
28-SDS x2
16700
7
5
7
8
8
10
10
12
12
13985
Uplift 1
133/160
133/160
115/125
6400
9145
9145
14060
14060
16700
100
4515
5540
5540
8310
8310
11745
5410
7685
7685
11810
11810
14030
115/125
5375
7685
7685
11810
11810
14030
100
1. Uplift loads have been increased for earthquake and wind loading, with no further increase allowed.
2. Specify H dimension. The Designer should check the shear capacity of the carried member to make sure it matches the hangers capacity. Maximum H 30".
3. Minimum header is based on the size necessary to fit screw pattern. Use the next size up that meets the minimum depth requirement.
[close]