Page 115 of Wood Construction Connectors 2006 Catalog by Simpson Strong-Tie
Typical SUL
Installation with
Bevel Cut Joist
(HSUL similar)
Typical SUR
Installation with
Square Cut Joist
(HSUR similar)
116
Engineered Wood Structural Composite Lumber Connectors
HRC Hip Ridge Connectors
For complementary top plate connection, see page 115
SUR/SUL/HSUR/HSUL Skewed 45 Hangers for I-Joist and SCL
HSUR
SUL2.56/11
MATERIAL: 16 gauge.
FINISH: Galvanized
INSTALLATION:
Use all specified fasteners. See General Notes.
On end of ridge-use optional diamond holes to secure the HRC.
Bend face flanges back flush with ridge, and complete nailing.
On face of ridge-adjust to correct height and install nails.
Double bevel-cut hip members to achieve full bearing capacity.
The HRC may be sloped to 45 with no reduction in loads.
CODES: See page 12 for Code Listing Key Chart.
Model
No.
Member Size
Fasteners
Doug Fir Larch/So. Pine
Allowable Loads
Spruce-Pine-Fir
Allowable Loads
W
Ridge
Carrying
Member
Each
Hip
Uplift
(133)
Uplift
(160)
Floor
(100)
Snow
(115)
Uplift
(133)
Uplift
(160)
Floor
(100)
Snow
(115)
HRC1.81
1
2x or
1 wide
16-10dx1
2-10dx1
240
290
720
830
210
250
625
720
Roof
(125)
900
Roof
Code
Ref.
(125)
780
160
1. Allowable loads shown are for each hip. Total load carried by the connector is double this number.
2. Uplift loads include a 33% and 60% increase for earthquake or wind loading; no further increase allowed; reduce where other loads govern.
3. Roof loads are 125% of floor loads unless limited by other criteria.
4. NAILS: 10dx1 0.148" dia. x 1 long. See page 16-17 for other nail sizes and information.
HRC1.81
U.S. Patent
5,380,116
Typical HRCInstallation
on the End of a Ridge
Optional
HRC1.81 Installation
The SUR/L1.81, 2.56 and New HSUR/L4.12, 4.75 and 5.12 are improved 45
skewed hangers designed specifically to ease the installation of single and double
I-Joists. In addition to Positive Angle Nailing these hangers encapsulate the top
flange of the I-Joist, so no web stiffeners are required for standard installation.
The full range of 45 skewed hangers feature obround nail holes on the acute
side allowing nails to be easily installed parallel to the header and joist. Installation
is further simplified with no required bevel cuts.
MATERIAL: See table. FINISH: Galvanized. Some products available in Z-MAX;
see Corrosion-Resistance, page 6-7.
INSTALLATION: Use all specified fasteners. See General Notes.
Illustrations show left and right skews SUR/L
(SUR=skewed right; SUL=skewed left).
The joist end may be square cut or bevel cut.
Web stiffeners are required for I-Joist applications except for the
SUR/L1.81, 2.56, HSUR/L4.12, 4.75 and 5.12.
Fill all round and obround nail holes with specified fasteners to achieve
table loads. Where noted,triangle holes in the joist flange may be filled for
additional uplift capacity (see Footnote 3).
OPTIONS: These hangers will accommodate a 40 to 50 skew.
Available with the A2 flange turned in on 2-2x and 4x models only (see illustration).
For example, specify HSURC410, HSULC410, SURC210-2, or SULC210-2.
CODES: See page 12 for Code Listing Key Chart.
This product is preferable to similar connectors because of a) easier installation,
b) higher loads, c) lower installed cost, or a combination of these features.
[close]