Page 118 of 195 ![]() |
![]() View extracted text
Page 118 of Wood Construction Connectors 2006 Catalog by Simpson Strong-Tie119 Glulam Beam Connectors FACE MOUNT HANGERS HU/HGUS Glulam Beam Double Shear Joist Hangers Carried Member Width Model No. Ga Dimensions Fasteners Allowable Loads Uplift (133) Uplift (160) DF/SP Species Header SPF Species Header W H B Face Joist Floor (100) Snow (115) Roof (125) Floor (100) Snow (115) Roof Code Ref. (125) 3 GLULAM 3 GLULAM HU212-2 (Min) 14 3 10 2 2 16-16d 6-10d 905 1085 2145 2465 2680 1855 2135 2320 HU212-2 (Max) HU210-2 (Min) HU210-2 (Max) 3 10 2 22-16d 10-10d 1505 1810 2950 3390 3685 2550 2935 3190 HU3.25/10.5 3 10 2 22-16d 10-10d 1505 1810 2950 3390 3685 2550 2935 3190 HU3.25/12 3 11 2 24-16d 12-10d 1810 2015 3215 3700 4020 2785 3200 3480 HU216-2 (Min) 3 13 2 20-16d 8-10d 1205 1445 2680 3080 3350 2320 2670 2900 HU216-2 (Max) 3 13 2 26-16d 12-10d 1810 2015 3485 4005 4355 3015 3470 3770 HGUS3.25/10 12 3 8 4 46-16d 16-16d HGUS3.25/12 3 10 4 56-16d 20-16d 5 GLULAM HU5.125/12 HU310-2 14 5 10 2 22-16d 8-16d 1430 1715 2950 3390 3685 2550 2935 3190 HU5.125/13.5 5 13 2 26-16d 12-16d 2145 2575 3485 4005 4355 3015 3470 3770 HU5.125/16 5 13 2 26-16d 12-16d 2145 2575 3485 4005 4355 3015 3470 3770 HGUS5.25/10 12 5 9 4 46-16d 16-16d HGUS5.25/12 5 10 4 56-16d 20-16d 6 GLULAM HGUS6.88/10 12 6 8 4 46-16d 16-16d HGUS6.88/12 6 10 4 54-16d 20-16d HGUS6.88/14 6 12 4 66-16d 22-16d 5 GLULAM 7 GLULAM See HHUS and HGUS in 7" Structural Composite Lumber section, page 96. See HHUS and HGUS in 5 Structural Composite Lumber section, page 96. For HUCQ's see page 91. See HHUS and HGUS in 3 Structural Composite Lumber section, page 95-96. For HUCQ's see page 91. 3 8 14-16d 6-10d 905 1085 1875 2155 2345 1625 1870 2030 2 3 8 18-16d 10-10d 1505 1810 2410 2775 3015 2090 2400 2610 3630 3630 8780 8940 8940 6725 6935 7080 4055 4055 9155 9155 9155 7080 7345 7520 26, 83, 124 26, 83, 124 160 124 26, 83, 124 124 133 160 133 133 3630 3630 8780 8940 8940 7510 7510 7510 4055 4055 9155 9155 9155 7690 7690 7690 3630 3630 8780 9625 9625 7595 8085 8085 4055 4055 9835 9835 9835 8260 8260 8260 5380 5380 11110 11110 11110 9330 5 8 2 14-16d 6-10d 905 1085 1875 2155 2345 1625 1870 2030 9330 9330 1. 10d commons or 16d sinkers may be used instead of the specified 16d at 0.85 of the table load value. 2. 16d sinkers may be used instead of the specified 10d commons with no load reduction. 3. Uplift loads based on Douglas Fir have been increased 33% and 60% for earthquake or wind loading with no further increase allowed. Divide by 1.33 and 1.60 for normal loading such as in cantilever construction. 4. MIN nailing quantity and load values fill all round holes; MAX nailing quantity and load values fill all round and triangle holes. 5.NAILS: 16d 0.162" dia. x 3 long, 10d 0.148" dia. x 3" long. See page 16-17 for other nail sizes and information. See Hanger Options on page 188 for hanger modifications, which may result in reduced loads. HU Most models have triangle and round holes. To achieve maximum loads, fill both round and triangle holes with common nails. HGUS hangers have the highest loads of any face mount hangers! All hangers in this series have double shear nailing. This patented innovation distributes the load through two points on each joist nail for greater strength. It also allows the use of fewer nails, faster installation, and the use of common nails for all connections. (Do not bend or remove tabs) MATERIAL: See tables. FINISH: Galvanized. Some products available in Z-MAX; see Corrosion-Resistance, page 6-7. INSTALLATION: Use all specified fasteners. See General Notes. HU can be installed filling round holes only, or filling round and triangle holes for maximum values. HGUS Nails must be driven at an angle through the joist or truss into the header to achieve the table loads. Not designed for nailer applications. With 3x carrying members, use 16dx2 (0.162" dia. x 2 long) nails into the header and 16d commons into the joist with no load reduction. With 2x carrying members, use 10dx1 (0.148" dia. x 1 long) nails into the header and 10d commons into the joist, and reduce the load to 0.64 of the table value. OPTIONS: HU hangers available with the header flanges turned in for 2 and larger widths, with no load reduction order HUC hanger. See Hanger Options on page 188, for sloped and/or skewed HU models, and HUC (concealed flange) models. Concealed flanges are not available for HGUS. Other sizes available; consult Simpson. See also HUS series. CODES: See page 12 for Code Listing Key Chart. Projection seat on most models for maximum bearing and section economy. Typical HU Installation Model configurations may differ from those shown. Some HU models do not have triangle holes. Consult factory for details. HGUS3.25/12 HU210-2 HU5.125/12 HUC210-2 Concealed Flanges Double Shear Nailing Top View Dome Double Shear Nailing Side View (available on some models) U.S. Patent 5,603,580 Double Shear Nailing Side View Do not bend tab[close] |
Page 118 of 195 ![]() |
All Copyrights are and remain property of Simpson Strong-Tie. Who-sells-it.com is not an official partner of Simpson Strong-Tie. |