Page 119 of 195 ![]() |
![]() View extracted text
Page 119 of Wood Construction Connectors 2006 Catalog by Simpson Strong-Tie120 Glulam Beam Connectors LGU/MGU/HGU/HHGU High Capacity Girder Hangers NEW! The GU hangers are a high-capacity girder hangers designed for situations where the header and joist are flush at top. This part can be used for retrofit on the framing members after they are temporarily placed in position. It uses Simpson Strong-Drive screws (SDS) to make installation fast and easy, with no pre-drilling required. MATERIAL: See table. FINISH: Galvanized. INSTALLATION: Use all specified fasteners. See General Notes. Install with Simpsons SDS x2 screws, which are provided with the GUs. (Note: lag screws will not achieve the same loads.) All multiple members must be fastened together to act as a single unit. Multiple member headers may require additional fasteners at the hanger locations. The quantity and location of the additional fasteners must be determined by the Designer. OPTIONS: Not available. CODES: See page 12 for Code Listing Key Chart. MGU Typical MGU Installation Ga Model No. Fasteners Dimensions Min. Header Depth 3 ha Allowable Loads Face LGU3.25 10 16-SDS x2 LGU5.25 10 16-SDS x2 Joist 12-SDS x2 12-SDS x2 W H 2 (min) 3 5 7 7 MGU5.25 10 24-SDS x2 16-SDS x2 5 8 Code Ref. SPF/HF DF/SP Uplift 1 Download 3 Uplift 1 Download 3 133/160 133/160 115/125 5380 5380 6595 MGU5.50 10 24-SDS x2 16-SDS x2 4515 4515 5540 5540 160 5 B 4 4 4 4 8 6595 MGU7.00 10 24-SDS x2 16-SDS x2 5540 7 4 8 6595 HGU5.25 7 36-SDS x2 24-SDS x2 8310 5 5 7 7 8 8 8 10 10 9895 HGU5.50 7 36-SDS x2 HGU7.00 7 36-SDS x2 24-SDS x2 24-SDS x2 5 7 10 10 HGU9.00 7 36-SDS x2 24-SDS x2 9 10 9895 9895 9895 HHGU5.50 3 44-SDS x2 28-SDS x2 8310 8310 8310 11745 5 5 5 5 5 12 13985 HHGU7.00 3 44-SDS x2 28-SDS x2 11745 7 5 12 13985 HHGU9.00 3 44-SDS x2 28-SDS x2 11745 6440 6440 9145 9145 9145 14060 14060 14060 14060 16700 16700 16700 100 6400 6400 9145 9145 9145 14060 14060 14060 14060 16700 16700 16700 9 5 10 10 10 12 12 12 12 13985 115/125 5410 5410 7685 7685 7685 11810 11810 11810 11810 14030 14030 14030 100 5375 5375 7685 7685 7685 11810 11810 11810 11810 14030 14030 14030 1. Uplift loads have been increased for earthquake and wind loading, with no further increase allowed. 2. Specify H dimension. The Designer should check the shear capacity of the carried member to make sure it matches the hangers capacity. Maximum H 30". 3. Minimum header is based on the size necessary to fit screw pattern. Use the next size up that meets the minimum depth requirement.[close] |
Page 119 of 195 ![]() |