Page 120 of Wood Construction Connectors 2006 Catalog by Simpson Strong-Tie
2 "
WNP2.6 and
WNP3.3
WPU
Model
Nailer
Top
Flange
Nailing
Allowable Loads
DF/SP
SPF
WNP/
WP
HW
2x
2-10dx1
2525
2500
3x
2-16dx2
3000
2510
2-2x
2-10d
3255
3255
4x
2-10d
3255
3255
4x
4-16d
5285
LSL
3375
The WPU, HWU and HW series purlin hangers offer the greatest design flexibility
and versatility.
MATERIAL: WNP/WPI/WPU 7 ga. top flange, 12 ga. stirrup; HW 3 ga. top flange,
11 ga. stirrup; HWU 3 ga. top flange, 10 ga, stirrup.
FINISH: Simpson gray paint; hot-dipped galvanized available: specify HDG.
ALLOWABLE LOADS: For hanger heights exceeding the joist height, the
allowable load is 0.50 of the table load.
INSTALLATION: Hangers may be welded to steel headers with for WPU/WNP/
WP/WPI, and for HW/HWU, by 1 fillet welds located at each end
of the top flange. Weld-on applications produce maximum allowable load listed.
See page 14 for weld information. Uplift loads do not apply to this application.
Hangers can support multi-ply carried members; the individual members must
be secured together to work as a single unit before installation into the hanger.
OPTIONS: See Hanger Options, page 188, for hanger modifications
and associated load reductions.
CODES: See page 12 for Code Listing Key Chart.
NAILER TABLE
HW
(HWU similar)
1. 16d sinkers (0.148" dia. x 3 long) may be used where 10d commons are called out with no load reduction.
2. Uplift loads are based on Doug Fir and have been increased 33% and 60% for earthquake or wind loading;
no further increase allowed. Divide by 1.33 and 1.60 for normal loading like cantilever construction.
3.NAILS: 16d 0.162" dia. x 3 long, 10d 0.148" dia. x 3" long,
10dx1 0.148" dia. x 1 long.
See page 16-17 for other nail sizes and information.
Some model configurations may differ from those shown.
Contact factory for details.
Model
Joist
Fasteners
Allowable Loads Header Type
Width
Depth
Top
Face
Joist
Uplift
(133
160)
LVL
PSL
LSL
DF/SP
SPF
I-Joist Masonry
Code
Ref.
1 to 7
3 to 30
3-10dx1
2-10dx1
2865
3250
2500
2000
2030
1 to 7
3 to 30
3-10d
2-10dx1
2525
3250
3650
3255
2525
1 to 7
3 to 30
3-16d
2-10dx1
3635
3320
3650
3255
2600
WPU
1 to 5
7 to 18
3-16d
4-16d
6-10dx1
775
4700
4880
3650
4165
4165
1 to 5
18 to 22
3-16d
4-16d
6-10dx1
485
4700
4880
3650
4165
4165
1 to 5
23 to 28
3-16d
4-16d
6-10dx1
315
4700
4880
3650
4165
4165
HW
1 to 7
3 to 32
4-10d
2-10dx1
3100
4000
5285
3100
1 to 7
3 to 32
4-16d
2-10dx1
5100
4000
4500
5285
3665
HWU
1 to 3
9 to 18
4-16d
4-16d
6-10dx1
810
6335
5500
5535
6335
5415
1 to 3
18 to 22
4-16d
4-16d
6-10dx1
765
6335
5500
5535
6335
5415
1 to 3
23 to 28
4-16d
4-16d
6-10dx1
635
6335
5500
5535
6335
5415
1 to 3
28 to 32
4-16d
4-16d
8-10dx1
1005
6335
5500
5535
6335
5415
4 to 7
9 to 18
4-16d
4-16d
6-10dx1
810
6000
5500
5535
6000
5415
4 to 7
18 to 22
4-16d
4-16d
6-10dx1
765
6000
5500
5535
6000
5415
4 to 7
23 to 28
4-16d
4-16d
6-10dx1
635
6000
5500
5535
6000
5415
4 to 7
28 to 32
4-16d
4-16d
8-10dx1
1005
6000
5500
5535
6000
5415
WNP/
WP
124
26, 124
26, 83,
124, 140
The table indicates the maximum
allowable loads for WNP hanger
used on wood nailers. Nailers are
wood members attached to the
top of a steel I-beam, concrete or
masonry wall. This table also
applies to sloped-seat hangers.
Typical HHB,
GB and HGB
Saddle
Installation
HHB, GB and
HGB are
acceptable
for weld-on
applications.
See Installation
Information.
TOP FLANGE HANGERS WPU/WNP/HW/HWU
See table on page 123. See Hanger Options on page 188 for hanger modifications,
which may result in reduced loads.
Precision forming with manufacturing quality control provides dimensional accuracy and
helps ensure proper bearing area and connection.
MATERIAL: See table on page 123.
FINISH: HHB, GB, HGB, all saddle hangers and all welded sloped and special hangers
Simpson gray paint. HHB may be ordered hot-dip galvanized; specify HDG.
INSTALLATION: Use specified fasteners. See General Notes.
HHB, GB and HGB may be used for weld-on applications. The minimum required weld to the
top flanges is x 2" fillet weld to each side of each top flange tab for 14 and 12 gauge and x 2" fillet weld to each side of each top flange tab for 7 gauge. Distribute the weld equally
on both top flanges. Welding cancels the top and face nailing requirements. Consult the code
for special considerations when welding galvanized steel. The area should be well-ventilated.
See page 14 for weld information. Weld on applications produce the maximum allowable load
listed. Uplift loads do not apply to welded applications.
Ledgers must be evaluated for each application separately. Check TF dimension, nail length
and nail location on ledger.
OPTIONS: HHB-other widths are available; specify W dimension (the minimum W dimension is 2 ").
Saddle hangers are made to order; add D to model (e.g. HHBD3); specify S (for saddle)
dimension. They may be used for most conditions except at end wall locations, and are
preferred for nailer applications.
The finish on special B hangers will depend on the manufacturing process used. Check
with your Simpson representative for details. Hot-dipped galvanized available: specify HDG.
B dimensions may be increased on some models. See Hanger Options, page 188.
121
Glulam Beam Connectors
TOP FLANGE HANGERS HHB/GB/HGB Beam Purlin Hangers
[close]