Page 127 of Wood Construction Connectors 2006 Catalog by Simpson Strong-Tie
128
Plated Truss Connectors
HTU Face Mount Truss Hangers
Standard Allowable Loads Maximum Hanger Gap)
The new HTU face mount truss hangers have nail
patterns designed specifically for shallow heel heights,
so that full allowable loads (with minimum nailing)
apply to heel heights as low as 3 ". Minimum and
maximum nailing options provide solutions for varying
heel heights and end conditions.
Alternate allowable loads are provided for gaps
between the end of the truss and the carrying member
greater than (maximum gap for standard allowable
loads is per ASTM D-1761).
MATERIAL: 16 gauge
FINISH: Galvanized
INSTALLATION:
Use all specified fasteners. See General Notes.
Can be installed filling round holes only, or filling
round and triangle holes for maximum values. For single 2x carrying members, use N10
(10dx1 nails into the header and reduce the
allowable download to 0.70 of the table value.
The allowable uplift is 100% of the table load.
See alternate installation for applications
using the HTU28 or HTU210 on a 2x6 carrying
member for additional uplift capacity.
CODES: See page 12 for Code Listing Key Chart.
1. See table footnotes above.
2. Maximum hanger gap for the alternate installation is ".
3. NAILS: 16d 0.162" dia. x 3 long, 10dx1 0.148" dia. x 1 long.
See page 16-17 for other nail sizes and information.
1. The maximum hanger gap is measured between the joist (or truss) end and the carrying member.
2. Minimum heel heights required for full table loads are based on a minimum 2:12 pitch.
3. Allowable load calculations are based on the 2001 NDS.
4. Uplift has been increased 33% and 60% for earthquake or wind loading with no further
increase allowed; reduce where other loads govern.
5. Wind (133) is a download rating.
6. For hanger gaps between and use the Alternate Allowable Loads.
7. Truss chord cross-grain tension may limit allowable loads. Refer to
Technical Bulletins T-ANSITPISPF, T-ANSITPISP and T-ANSITPIDF for
allowable loads that consider ANSI/TPI 1-2002 wood member design criteria.
8. Loads shown are based on truss or joist with 3 minimum heel height.
9. NAILS: 16d 0.162" dia. x 3 long, 10d 0.148" dia. x 3" long,
10dx1 0.148" dia. x 1 long. See page 16-17 for other nail sizes
and information.
HTU26
HTU Installation for Standard Allowable Loads
(For maximum gap,
use Alternate Allowable Loads.)
Fasteners
Model
No.
Carrying
Member
Carried
Member
Floor
(100)
Snow
(115)
Roof
(125)
Wind
(133)
Uplift
(133/
160)
Floor
(100)
Snow
(115)
Roof
(125)
Wind
(133)
Uplift
(133/
160)
Doug Fir-Larch/Southern Pine
Allowable Loads
Spruce-Pine-Fir/Hem Fir
Allowable Loads
Min.
Heel
Height
(in.)
Code
Ref.
HTU26 (Min)
10-16d
14-10dx1
925
1440
1660
1800
1915
HTU26 (Max)
10-16d
20-10dx1
1310
1440
1660
1800
1915
HTU28 (Max)
20-16d
26-10dx1
2205
2880
3310
3600
3840
HTU210 (Max)
20-16d
32-10dx1
3155
2880
3310
3600
3840
3
5
7
9
Minimum
Carrying
Member
2-2x4
2-2x4
2-2x6
2-2x6
795
1245
1430
1555
1655
1125
1245
1430
1555
1655
133
1895
2480
2850
2925
2925
2715
2480
2850
2925
2925
Alternate Installation -
HTU28 installed on
2x6 carrying member
(HTU210 similar)
Dimensions
Fasteners
SINGLE 2x SIZES
DOUBLE 2x SIZES
Model
No.
Carrying
Member
Carried
Member
Floor
(100)
Snow
(115)
Roof
(125)
Wind
(133)
Uplift
(133/
160)
Floor
(100)
Snow
(115)
Roof
(125)
Wind
(133)
Uplift
(133/
160)
Doug Fir-Larch/Southern Pine
Allowable Loads
Spruce-Pine-Fir/Hem Fir
Allowable Loads
Min.
Heel
Height
W
H
B
Code
Ref.
HTU26 (Min)
20-16d
14-10dx1
1250
2880
3200
3200
3200
HTU26 (Max)
20-16d
20-10dx1
1555
2880
3310
3600
3840
HTU28 (Min)
26-16d
14-10dx1
1235
3745
3895
3895
3895
HTU28 (Max)
26-16d
26-10dx1
2140
3745
4305
4680
4990
HTU210 (Min)
32-16d
14-10dx1
1330
4355
4355
4355
4355
HTU210 (Max)
32-16d
32-10dx1
3315
4610
5300
5760
5995
HTU26-2 (Min)
20-16d
14-10d
1515
2880
3310
3600
3840
HTU26-2 (Max)
20-16d
20-10d
2175
2880
3310
3600
3840
HTU28-2 (Min)
26-16d
14-10d
1530
3745
4305
4305
4305
HTU28-2 (Max)
26-16d
26-10d
3485
3745
4305
4680
4990
HTU210-2 (Min)
32-16d
14-10d
4610
4815
4815
4815
HTU210-2 (Max)
32-16d
3
3
3
3
3
3
3
3
3
3
3
3
5
5
7
7
9
9
5
5
7
7
9
9
1
1
1
1
1
1
3
3
3
3
3
3
32-10d
4110
4610
5300
5760
6145
3
5
3
7
3
9
3
5
3
7
3
9
1075
2015
2015
2015
2015
HTU26 8
20-16d
11-10dx1
730
2880
3045
3045
3045
3
5
1
3
630
1815
1920
1920
1920
1335
2480
2850
3120
3320
1060
2920
2920
2920
2920
133
133
1840
3225
3710
4055
4315
1145
3265
3265
3265
3265
2850
3970
4565
4990
5155
1305
2465
2465
2465
2465
1870
2480
2825
3120
3310
1315
3225
3235
3235
3235
2995
3225
3710
4055
4315
3610
3610
3610
3610
3535
3970
4565
4990
5310
1540
1325
Alternate Installation Table for 2x4 and 2x6 Carrying Member
Typical HTU26
Minimum Nailing
Installation
[close]