TRUSS HIP/JACK
GIRDERS
Model
No.
Header
Fasteners
Doug-Fir-Larch/So. Pine Allowable Loads
Carrying
Member
Hips (total)
Jack
Uplift (133 160)
Floor (100)
Snow (115)
Roof (125/133/160)
Hip
Jack
Total
Hip
Jack
Total
Hip
Jack
Total
Hip
Jack
Total
Code
Ref.
MTHM
2 ply 2x4
22-16d
16-10dx1
4-10dx1
715
360
1790
1215
605
3035
1395
700
3490
1520
760
3800
140
140
2 ply 2x6
34-16d
16-10dx1
4-10dx1
715
360
1790
1860
930
4650
1860
930
4650
1860
930
4650
2 ply 2x8
42-16d
16-10dx1
4-10dx1
715
360
1790
2010
1005
5025
2010
1005
5025
2010
1005
5025
MTHM-2
2 ply 2x6
39-16d
16-10dx1
4-10dx1
745
370
1860
1955
980
4890
1955
980
4890
1955
980
4890
2 ply 2x8
47-16d
16-10dx1
4-10dx1
745
370
1860
2470
1235
6175
2470
1235
6175
2470
1235
6175
Model
No.
Header
Fasteners
Spruce-Pine-Fir Allowable Loads
Carrying
Member
Hips (total)
Jack
Uplift (133 160)
Floor (100)
Snow (115)
Roof (125/133/160)
Hip
Jack
Total
Hip
Jack
Total
Hip
Jack
Total
Hip
Jack
Total
MTHM
2 ply 2x4
22-16d
16-10dx1
4-10dx1
580
290
1450
1055
530
2640
1215
605
3035
1320
660
3300
2 ply 2x6
34-16d
16-10dx1
4-10dx1
580
290
1450
1600
800
4000
1600
800
4000
1600
800
4000
2 ply 2x8
42-16d
16-10dx1
4-10dx1
580
290
1450
1730
865
4325
1730
865
4325
1730
865
4325
MTHM-2
2 ply 2x6
39-16d
16-10dx1
4-10dx1
600
300
1500
1680
840
4200
1680
840
4200
1680
840
4200
2 ply 2x8
47-16d
16-10dx1
4-10dx1
600
300
1500
2125
1060
5310
2125
1060
5310
2125
1060
5310
Code
Ref.
MTHM
Top View
Left Hand Hip
Installation
Model
No.
Header
Fasteners
Doug-Fir-Larch/So. Pine Allowable Loads
Carrying
Member
Hip
Jack
Uplift (133 160)
Floor (100)
Snow (115)
Roof (125/133/160)
Hip
Jack
Total
Hip
Jack
Total
Hip
Jack
Total
Hip
Jack
Total
MTHM
2 ply 2x4
22-16d
8-10dx1
4-10dx1
805
270
1075
2185
730
2915
2185
730
2915
2185
730
2915
2 ply 2x6
34-16d
8-10dx1
4-10dx1
805
270
1075
2630
875
3505
2630
875
3505
2630
875
3505
2 ply 2x8
42-16d
8-10dx1
4-10dx1
805
270
1075
3250
1085
4335
3250
1085
4335
3250
1085
4335
MTHM-2
2 ply 2x6
39-16d
8-10dx1
4-10dx1
835
280
1115
2800
935
3735
2800
935
3735
2800
935
3735
2 ply 2x8
47-16d
8-10dx1
4-10dx1
835
280
1115
3375
1125
4500
3375
1125
4500
3375
1125
4500
Model
No.
Header
Fasteners
Spruce-Pine-Fir Allowable Loads
Carrying
Member
Hip
Jack
Uplift (133 160)
Floor (100)
Snow (115)
Roof (125/133/160)
Hip
Jack
Total
Hip
Jack
Total
Hip
Jack
Total
Hip
Jack
Total
MTHM
2 ply 2x4
22-16d
8-10dx1
4-10dx1
655
220
875
1880
625
2505
1880
625
2505
1880
625
2505
2 ply 2x6
34-16d
8-10dx1
4-10dx1
655
220
875
2260
755
3015
2260
755
3015
2260
755
3015
2 ply 2x8
42-16d
8-10dx1
4-10dx1
655
220
875
2795
930
3725
2795
930
3725
2795
930
3725
MTHM-2
2 ply 2x6
39-16d
8-10dx1
4-10dx1
680
225
905
2510
835
3345
2510
835
3345
2510
835
3345
2 ply 2x8
47-16d
8-10dx1
4-10dx1
680
225
905
2905
970
3875
2905
970
3875
2905
970
3875
Code
Ref.
140
Code
Ref.
140
Right or Left Hand Hip Installation (Two Member Connection)
Terminal Type Installation (Three Member Connection)
MTHM
Top View
Installation
MTHM
Top View
Right Hand Hip
Installation
MTHM Top View
Terminal Installation
Without Center
Common Jack
MTHM
(MTHM-2 similar)
U.S. Patent 5,253,465
Typical MTHM Installation
(2 Hips and a Jack to Girder Truss)
Medium to high load capacity single-piece connectors designed
to carry multiple truss members. Can be used for both terminal and
right or left hand hip applications.
MATERIAL: 12 gauge. FINISH: Galvanized
INSTALLATION: Use all specified fasteners. See General Notes.
All multiple members must be fastened together to act as
a single unit.
Should be attached to a double girder truss to allow for
required minimum nail penetration.
With single 2x carrying members, use 10dx1 nails with
0.67 of the table values.
For terminal installation, distribute 40% of total load to
each hip member and 20% to the jack.
For left or right hand hip installation, distribute 65% to 85%
of total load to the hip member.
CODES: See page 12 for Code Listing Key Chart.
1. Allowable loads have been increased 33% and 60% for earthquake or wind
loading with no further increase allowed; reduce where other loads govern.
2. Hip loads are for each hip.
3. Wind (133) is a download rating.
4. Other hip/jack load distributions are allowed if the sum of all three carried
members does not exceed the total load and the hip members are equally loaded.
5. Combine hip and jack loads for total capacity. For terminal hips divide the total allowable load by 2
to determine the allowable load for each hip.
6. Truss chord cross-grain tension may limit allowable loads. Refer to Technical Bulletins T-ANSITPISPF,
T-ANSITPISP and T-ANSITPIDF for allowable loads that consider ANSI/TPI 1-2002 wood member design criteria.
7. NAILS: 16d 0.162" dia. x 3 long, 10dx1 0.148" dia. x 1 long.
See page 16-17 for other nail sizes and information.
MTHM-2
Top View
Installation
135
Plated Truss Connectors
MTHM/MTHM-2 Multiple Truss Hangers