Page 142 of Wood Construction Connectors 2006 Catalog by Simpson Strong-Tie
143
Plated Truss Connectors
TBE Truss Bearing Enhancers
TC Truss Connectors
ALTERNATE INSTALLATION
(See illustrations at right)
Pre-sheathed shearwall.
Bend tab along slot and nail
one leg to top of the plate.
See table footnotes on opposite page.
Model
No.
Alternate Installation Allowable Loads 5,6
Doug-Fir-Larch/So. Pine
Spruce-Pine-Fir
(133/160)
(133/160)
F2
F3
F2
F3
TBE4
1000
300
860
260
TBE6
TBE6 Installed
on Double 2x8 Top Plate
Model
No.
Fasteners
Doug-Fir-Larch/So. Pine
Allowable Loads
Spruce-Pine-Fir
Allowable Loads
Truss
Plate
Uplift
(133)
Uplift
(160)
Uplift
(133)
Uplift
(160)
TC24
4-10d
4-10d
500
600
410
410
TC26
5-10d
6-10d
625
750
540
550
39, 140
3, 39,
121, 140
TC28
5-10d
6-10d
625
750
540
550
Code
Ref.
See footnotes below.
TC24
U.S. Patent 4,932,173
TC26
(TC28 similar)
Typical TC24 Installation
Optional TC26 Installation for Grouted
Concrete Block using a Wood Nailer
(8², 10², 12² Wall Installation similar)
Optional TC26 Installation for Grouted
Concrete Block using Titen Screws
Model
No.
Fasteners
Doug-Fir-Larch/
So. Pine
Allowable Loads
Spruce-Pine-Fir
Allowable Loads
Masonry
Allowable Loads
Truss
Plate
Uplift
(133)
Uplift
(160)
Uplift
(133)
Uplift
(160)
Uplift
(133)
Uplift
(160)
TC26
5-10dx1
6-10dx1
360
430
310
350
5-10d
6-10d
375
450
325
390
5-10d
6- x2 Titen
195
195
121
Code
Ref.
1. Loads have been increased 33% and 60% for earthquake or wind loading;
no further increase allowed; reduce where other loads govern.
2. Grout strength is 2000 psi minimum.
3. Nail values based on single 2x truss.
4. Optional TC26 installation with 10d nails requires minimum 3² top plate thickness.
5. NAILS: 10d 0.148" dia. x 3" long, 10dx1 0.148" dia. x 1 long.
See page 16-17 for other nail sizes and information.
OPTIONAL TC INSTALLATION TABLE
Alternate Installation Allowable Down Loads are
0.80 of the TBE only table loads on page 142.
The TC truss connector is an ideal connector for scissor
trusses and can allow horizontal movement up to 1 ". The
TC also attaches plated trusses to top plates or sill plates to
resist uplift forces. Typically used on one or both ends of
truss as determined by the Designer.
MATERIAL: 16 gauge
FINISH: Galvanized
INSTALLATION:
Use all specified fasteners. See General Notes.
Drive 10d nails into the truss at the inside end of the
slotted holes (inside end is towards the center of the
truss). Do not seat these nails into the truss-allow
room under the nail head for movement of the truss
with respect to the wall.
After installation of roofing materials nails may be
required to be fully seated into the truss.
(As required by the Designer or Truss Designer.)
Optional TC Installation
Bend one flange up 90 . Drive specified nails into the
top and face of the top plates or install Titen screws
into the top and face of masonry wall. See optional
load tables and installation details.
CODES: See page 12 for Code Listing Key Chart.
[close]