MATERIAL: 18 gauge
FINISH: Galvanized
INSTALLATION: Use all specified fasteners; see General Notes.
The HTC has a 2 slot to accommodate truss movement
The S/HTC is available for steel truss applications.
This connector has high lateral capacity.
CODES: See page 12 for Code Listing Key Chart.
1. Loads may not be increased for short-term loading.
2. Truss or rafter must be bearing on top plate to achieve the allowable loads
under WITHOUT GAP.
3. When installed with maximum 1 space between rafter or truss and top
plate use loads under WITH 1 GAP. Where loads are not required,
space is not limited to 1 ".
4. NAILS: 10d 0.148" dia. x 3" long.
See page 16-17 for other nail sizes and information.
Model
No.
Dimensions
Fasteners
Allowable Loads 1 (133 160)
Top Plate
Base
Slot
Without Gap 2
With 1 Gap 3
F1
F2
F1
F2
2x6 Plate
2x4 Plate
6-10d
390
305
85
280
160
6-10d
3-10d
3-10d
485
280
155
280
HTC4
Code
Ref.
Nails should not be driven
completely flush against
the connector, to allow
vertical truss movement.
Allow
gap between
nailhead and
truss clip to
help prevent
squeaking
HTC4
Typical HTC4 Installation
on a 2x4 Plate
Typical HTC4 Installation
on a 2x6 Plate
STC/STCT/DTC Roof Truss Clips
STC
DTC
STCT
Typical STC Installation with DS
Nails should not be
driven completely
flush against the
connector, to allow
vertical truss
movement.
Model
No.
Fasteners
Allowable Loads 1 (133 160)
Base
Slot
Without Gap 2
With Gap 3
F1
F2
F1
F2
STC
2-8d
1-8d
85
50
35
35
170
STCT
2-8d
1-8d
DTC
4-8d
2-8d
125
210
85
135
Code
Ref.
For alignment control between a roof truss and nonbearing
walls; the 1 slot permits vertical truss chord movement when
loads are applied.
MATERIAL: 18 gauge
FINISH: Galvanized
INSTALLATION: Use all specified fasteners; see General Notes.
Use STC or DTC depending on required loads. STC,
installed with Drywall Stop (DS), helps prevent fasteners
tearing through the ceiling sheetrock (see illustration).
Use STCT where truss or rafter is separated from the top
plate of the nonbearing wall.
Install slot nails in the middle of the slot.
CODES: See page 12 for Code Listing Key Chart.
1. Loads may not be increased for short-term loading.
2. Truss or rafter must be bearing on top plate to achieve the
allowable loads under WITHOUT GAP.
3. When installed with maximum space between rafter or truss
and top plate, use loads listed under WITH GAP. Where loads
are not required, space is not limited to ".
4. NAILS: 8d 0.131" dia. x 2 long.
See page 16-17 for other nail sizes and information.