Wood Construction Connectors 2006 Catalog [Entire catalog in thumbnail view]Wood Construction Connectors 2006 Catalog [6 pages in thumbnail view]Wood Construction Connectors 2006 Catalog [Page in normal view]Wood Construction Connectors 2006 Catalog [Page in fullsize view]            Wood Construction Connectors 2006 Catalog [First page]    Wood Construction Connectors 2006 Catalog [Previous page]    Page 149 of 195    Wood Construction Connectors 2006 Catalog [Next page]    Wood Construction Connectors 2006 Catalog [Last page]            Wood Construction Connectors 2006 Catalog catalog view Downloadable PDF catalog Wood Construction Connectors 2006 Catalog Flash page flip catalog Wood Construction Connectors 2006 Catalog Visitor statistics of Wood Construction Connectors 2006 Catalog

Zoom in
View extracted text

Page 149 of Wood Construction Connectors 2006 Catalog by Simpson Strong-Tie

The embedded truss anchor series provides an engineered method to properly attach roof trusses to concrete and masonry walls. The products are designed with staggered nail patterns for greater uplift resistance. Information regarding the use of two anchors on single- and multi-ply trusses is included. The TSS, a companion product of the META, provides a moisture barrier between the concrete and truss. The preassembled unit is riveted with no height adjustment. MATERIAL: HHETA-14 gauge; HETA-16 gauge; HETAL-strap 16 gauge, truss seat 18 gauge; META-18 gauge; TSS-22 gauge. FINISH: Galvanized. Some products available in Z-MAX; see Corrosion Resistance, page 6-7. INSTALLATION: Use all specified fasteners. See General Notes. The META, HETA and HHETA are embedded 4" into a concrete beam or grouted block wall; HETAL is embedded 5 ". Do not drive nails through the truss plate on the opposite side of the truss, which could force the plate off the truss. The TSS moisture barrier may be preattached to the truss using 6d commons. CODES: See page 12 for Code Listing Key Chart. Model No. H Uplift Load 133 Load Duration Increase Uplift Load 160 Load Duration Increase Code Ref. META16 META18 META20 6 META22 META24 META40 HETA16 12 HETA20 6 16 HETA24 20 HETA40 36 HHETA16 12 HHETA20 6 16 HHETA24 20 HHETA40 36 HETAL12 7 HETAL16 11 HETAL20 15 12 14 16 18 20 36 META12 META14 HETA12 128 8, 62, 121, 128 8 10 8 128 8, 62, 121, 128 128 HHETA12 8 Lateral Loads (133 160) 10dx1 Quantity Load Quantity Load Quantity Load Quantity Load 16d 10dx1 16d F1 F2 335 4 635 4 335 4 635 4 335 4 635 4 335 4 635 4 335 4 635 4 335 4 635 4 335 4 730 4 335 4 730 4 335 4 730 4 335 4 730 4 335 4 730 4 65 85 335 4 730 4 335 4 730 4 335 4 730 4 415 1100 415 1100 415 1100 65 85 65 85 65 85 7 7 7 7 7 7 9 9 9 10 7 9 7 7 10 10 10 11 14 14 1450 1450 1450 1450 1450 1450 1810 1810 1810 1810 2235 2235 2235 2235 1515 1810 1810 1450 1450 1520 1450 1450 1450 1450 1450 1450 1810 1810 1810 1810 2235 2235 2235 2235 1770 1810 1810 1450 1450 1780 6 6 6 6 6 6 8 8 8 8 9 9 9 9 11 12 12 6 6 7 7 1565 1820 7 9 9 9 9 9 9 10 10 10 12 7 10 7 9 12 12 12 11 15 15 1450 1450 1450 1450 1450 1450 1805 1805 1805 1805 2235 2235 2235 2235 1265 1810 1810 1450 1240 1265 1450 1450 1450 1450 1450 1450 1810 1810 1810 1810 2235 2235 2235 2235 1475 1810 1810 1450 1450 1475 7 7 7 7 7 7 9 9 9 9 11 7 1305 1520 7 11 11 11 11 13 13 7 7 7 1.Loads include a 33% or 60% load duration increase on the fasteners for seismic or wind loading, but do not include a 33% stress increase on the steel capacity. Refer to page 13 for further explanation. 2.Five nails must be installed into the truss seat of the HETAL. 3.Parallel-to-plate load towards face of HETAL is 1975 lbs. 4.Lateral loads for products noted in the table are based on a minimum installation of 12 nails and the strap wrapped over the heel. 5.Minimum f'c is 2,000psi. HETA20 (HHETA similar) HETAL Typical HETA20 with TSS Installation 6. On the META20, HETA20 and HHETA20, it is acceptable to use a reduced number of fasteners provided that there is a reduction in uplift load capacity. See example on page 158. Lateral loads do not apply for reduced nailing. 7. Minimum spacing is 2 times the embedment depth for full load. 8. See instruction to the Designer page 15 for loads in multiple directions. 9. Single ply trusses may use either 10dx1 (0.148 dia. x 1 or 16d (0.162 dia. x 3 nails. 2 or 3 ply trusses shall use 16d (0.162 dia. x 3 nails. 10. NAILS: 16d 0.162" dia. x 3 long, 10dx1 0.148" dia. x 1 long. See page 16-17 for other nail sizes and information. Available with additional corrosion protection. Check with factory. Model No. W TSS2 1 TSS2-2 3 TSS4 3 Moisture barrier not shown (Typ.) META with TSS 150 Masonry Connectors META/HETA/HHETA/HETAL/TSS Embedded Truss Anchors and Truss Seat Snap-In

[close]
Wood Construction Connectors 2006 Catalog [Entire catalog in thumbnail view]Wood Construction Connectors 2006 Catalog [6 pages in thumbnail view]Wood Construction Connectors 2006 Catalog [Page in normal view]Wood Construction Connectors 2006 Catalog [Page in fullsize view]            Wood Construction Connectors 2006 Catalog [First page]    Wood Construction Connectors 2006 Catalog [Previous page]    Page 149 of 195    Wood Construction Connectors 2006 Catalog [Next page]    Wood Construction Connectors 2006 Catalog [Last page]            Wood Construction Connectors 2006 Catalog catalog view Downloadable PDF catalog Wood Construction Connectors 2006 Catalog Flash page flip catalog Wood Construction Connectors 2006 Catalog Visitor statistics of Wood Construction Connectors 2006 Catalog



All Copyrights are and remain property of Simpson Strong-Tie. Who-sells-it.com is not an official partner of Simpson Strong-Tie.


Home | Latest catalogs | Contact

© 2006-2008 by who-sells-it.com