Page 150 of Wood Construction Connectors 2006 Catalog by Simpson Strong-Tie
151
Masonry Connectors
META/HETA/HHETA/HETAL/TSS Embedded Truss Anchors and Truss Seat Snap-In
1. For concrete tie beam applications for 2 or 3 ply trusses,
increase the META load 35% and the HETA load 8%.
2. Divide total number of fasteners equally between both straps.
3. Minimum fc is 2,500 psi.
4. See instruction to the Designer page 15 for loads in
multiple directions.
5. Lateral loads are based on a minimum installation of 12 nails
and the strap wrapped over the heel.
6. Loads include a 33% or 60% load duration increase on the
fasteners for seismic or wind loading, but do not include a
33% stress increase on the steel capacity. Refer to page 13
for further explanation.
7. NAILS: 16d 0.162" dia. x 3 long,
10dx1 0.148" dia. x 1 long.
See page 16-17 for other nail sizes and information.
Typical META
Installed with TSS
Typical Installation
with two METAs
Model
No.
Double Embedded Anchor Installation Into Grouted CMU Bond Beam
Uplift (133)
Uplift (160)
Code
Ref.
META
HETA
128
121, 128
10-10dx1
10-10dx1
2035
1985
2500
1900
12-16d
14-16d
12-10dx1
12-10dx1
2035
1985
2500
1900
14-16d
14-16d
Lateral Loads
(133 160)
SP
1 Ply So. Pine Truss
Fasteners
Load
Fasteners
Load
Fasteners
Load
Fasteners
Load
2 or 3 Ply So. Pine Truss
1 Ply So. Pine Truss
2 or 3 Ply So. Pine Truss
F1
F2
1000
1305
1040
1055
MSTAM and MSTCM models are designed
for wood to masonry applications.
The MSTC series has countersunk nail slots
for a lower nailing profile. Coined edges ensure
safer handling.
FINISH: Galvanized.
Some products are available in stainless
steel or Z-MAX; see Corrosion-Resistance,
page 6-7.
INSTALLATION:
Use all specified fasteners.
See General Notes.
Attach to grouted concrete block.
CODES: See page 12 for Code Listing Key Chart.
Model
No.
Ga
Dimensions
Fasteners (Total)
Allowable Tension Loads
W
L
Nails
CMU
Concrete
(133)
(160)
DF/SP
SPF/HF
MSTAM24
18
1
24
9-10d
5- x2 Titen
1465
1500
MSTAM36
16
1
36
13-10d
8- x2 Titen
1870
1870
MSTCM40
16
3
40
26-16d sinkers
14- x2 Titen
5- x1 Titen
8- x1 Titen
14- x1 Titen
4250
4250
(133)
(160)
1270
1500
1870
1870
3745
4250
Code
Ref.
128
151
Masonry Application
1.Loads include a 33% or 60% load duration increase on the fasteners for earthquake or wind loading, but DO NOT include a
33% stress increase on the steel capacity. Refer to page 13 for further explanation.
2.Minimum edge distance 1 using Titen screws.
3. NAILS: 16d Sinker 0.148" dia. x 3 long, 10d 0.148" dia. x 3" long.
See page 16-17 for other nail sizes and information.
1. NAILS: 16d Sinker 0.148" dia. x 3 long, 10d 0.148" dia. x 3" long.
See page 16-17 for other nail sizes and information.
Typical
MSTAM36
Installation
MSTCM40
Model
No.
Clear
Span
Fasteners (Total)
Allowable Tension Loads
Nails
CMU
(133)
(160)
MSTAM36
16 or 18
8-10d
4- x2 Titen
1335
1600
MSTCM40
16 or 18
14-16d Sinkers
10- x 2 Titen
2335
2800
(133)
(160)
1150
1380
2015
2420
Code
Ref.
128
151
Concrete
4- x1 Titen
10- x1 Titen
(DF/SP)
SPF/HF
MSTAM36
Floor-to-Floor Clear Span Table
Available with additional corrosion protection. Check with factory.
MSTAM/MSTCM Straps Ties