Page 152 of Wood Construction Connectors 2006 Catalog by Simpson Strong-Tie
LGT2
Model
No.
W
O.C.
Dim
Between
Anchors
Fasteners
DF/SP
Allowable
Uplift Loads
(133/160)
SPF
Allowable
Uplift Loads
(133/160)
Anchor Dia.
Girder
Concrete
HGT-2
3
3
5
16-10d
10980
6485
MGT
22-10d
LGT2
3
16-16d Sinker
12-SDS x2
7- x1 Titen
7- x2 Titen
4- x5 Titen HD
4- x5 Titen HD
2150
1850
3685
3170
3965
3330
HGT-3
4
7
16-10d
10530
9035
HGT-4
6
9
16-10d
9250
9250
Model
No.
W
O.C.
Dim
Between
Anchors
Fasteners
DF/SP
Allowable
Uplift Loads
(133/160)
SPF
Allowable
Uplift Loads
(133/160)
Girder
CMU
Concrete
Code
Ref.
Code
Ref.
Masonry Application
1-
2-
2-
2-
125
160
LGT3-SDS2.5
5
125
6, 62,
121
Typical HGT-2 Installation
into Concrete
Typical MGT Installation
Typical LGT2
Installation into Masonry
NEW! LGT3-SDS2.5 is a heavy girder truss tiedown for
3-ply Girder Trusses. Featuring SDS screws into the truss
for higher load capacity.
The LGT2 and MGT provide lighter load alternatives for
girder tiedowns. The HGT-4 is sized for 4-2x widths. This
series provides high uplift resistance for wood frame and
concrete block construction. The HGT can be installed on
trusses and beams with top chord slopes from 3:12 to 8:12.
Available in 2-ply, 3-ply and 4-ply widths.
MATERIAL: LGT2 14 ga; LGT3, MGT 12 ga; HGT 7 ga.
FINISH: HGT Simpson gray paint;
LGT, MGT galvanized
INSTALLATION: When the HGT-3 is used with a 2-ply girder or beam,
shimming is required. Fasten to act as one unit.
Attach to grouted concrete block with a minimum
one #5 rebar horizontal in the top lintel block.
Minimum f I
c
= 2500 psi maximum aggregate ".
See page 167 for wood applications.
CODES: See page 12 for Code Listing Key Chart.
1. Attached members must be designed to resist applied loads.
2. To achieve the loads listed, anchorage into a concrete block bond beam shall be designed by the Designer.
3. To achieve the loads listed for the MGT and HGT, anchorage into a 8" wide concrete tie-beam or grouted and
reinforced CMU tie-beam can be made using Simpson SET epoxy with a diameter anchor and a minimum
embedment depth of 12". Vertical reinforcement may be required to transfer the loads per Designer.
4. Allowable loads have been increased for earthquake or wind loading; no further increase allowed;
reduce where other loads govern.
5. LGT2: F1 load 700, F2 load 170.
6. LGT3-SDS2.5: F1 load 795, F2 load 410 (DF/SP).
7. See page 147 for Titen screw information.
8. The MGT can be installed with straps vertical for full table load provided all specified nails are
installed to either a solid header or minimum double 2x6 web.
9. Table allowable loads were determined using test ultimate/3 or nail calculation values.
10. NAILS: 16d Sinker 0.148" dia. x 3 long, 10d 0.148" dia. x 3" long.
See page 16-17 for other nail sizes and information.
HGT-2
(HGT-3 and HGT-4 similar)
MGT
LGT3-SDS2.5
153
Masonry Connectors
LGT3-SDS2.5/LGT2/MGT/HGT Heavy Girder Tiedowns