Page 157 of Wood Construction Connectors 2006 Catalog by Simpson Strong-Tie
TS Twist Straps
39"
Clear Span 78"
86-16d
45"
Clear span 90"
100-16d
9235
1 "
45"
Clear Span 90"
100-10d
51"
Clear span 102"
114-10d
9235
1 "
76"
Clear Span 152"
86-16d
89"
Clear span 178"
100-16d
9235
3 "
89"
Clear Span 178"
100-10d
101"
Clear span 202"
114-10d
9235
3 "
30"
Clear Span 60"
66-16d
35"
Clear span 70"
76-16d
6490
1 "
34"
Clear Span 68"
76-10d
40"
Clear span 80"
88-10d
6490
1 "
59"
Clear Span 118"
66-16d
68"
Clear span 136"
76-16d
6490
3 "
68"
Clear Span 136"
76-10d
78"
Clear span 156"
88-10d
6490
3 "
23"
Clear Span 46"
56-16d sinkers
27"
Clear span 54"
66-16d sinkers
4585
1 "
45"
Clear Span 90"
56-16d sinkers
52"
Clear span 104" 66-16d sinkers
4585
3"
CS14
100'
16"
Clear Span 32"
30-10d
19"
Clear span 38"
34-10d
2490
CS14-R
25'
16"
Clear Span 32"
30-10d
19"
Clear span 38"
34-10d
2490
CS16
150'
14"
Clear Span 28"
26-8d
17"
Clear span 34"
30-8d
1705
CS16-R
25'
12"
Clear Span 24"
22-10d
15"
Clear span 30"
26-10d
1705
CS18S
100'
12"
Clear Span 24"
22-8d
15"
Clear span 30"
26-8d
1370
CS18
200'
10"
Clear Span 20"
18-10d
12"
Clear span 24"
20-10d
1370
CS18-R
25'
10"
Clear Span 20"
18-10d
12"
Clear span 24"
20-10d
1370
CS20
250'
10"
Clear Span 20"
18-8d
12"
Clear span 24"
20-8d
1030
CS20-R
25'
8"
Clear Span 16"
14-10d
10"
Clear span 20"
16-10d
1030
CS22
300'
8"
Clear Span 16"
14-8d
10"
Clear span 20"
16-8d
845
CS22-R
25'
7"
Clear Span 14"
12-10d
9"
Clear span 18"
14-10d
845
Nail
Spacing
o.c.
(in a row)
Code
Ref.
52 '
54'
CMSTC16
CMST12
CMST14
Model
No.
Total
L
Ga
40'
14
2 "
2 "
Allowable
Tension
Loads (133)
12
14
16
16
18
20
22
End L
Cut Length
DF/SP
SPF/HF
End L
Cut Length
Fasteners
Fasteners
3, 28,
39, 97,
104,
121,
128
170
128
3, 9,
39, 62,
104,
128
1.Loads include a 33% or 60% load duration increase on the fasteners for seismic or wind loading, but
DO NOT include a 33% stress increase on the steel capacity. Refer to page 13 for further explanation.
2.Use half of the required nails in each member being connected to achieve the listed loads.
3.Calculate the connector value for a reduced number of nails as follows:
4. NAILS: 16d 0.162" dia. x 3 long, 16d Sinker 0.148" dia. x 3 long, 10d 0.148" dia. x 3" long.
See page 16-17 for other nail sizes and information.
Typical CS Installation
as a Floor-to-Floor Tie
(CMST requires
minimum 2-2x studs)
Nails not
required in
clear span
CS16 Hole Pattern
(all other CS straps similar)
CMST14 Hole Pattern
(CMST12 similar)
CMSTC16 Hole Pattern
No. of Nails Used
Allowable Load =
x Table Load
No. of Nails in Table
Gauge stamped on part for
easy identification
CMSTC provides nail slots for easy installation and coined edges for safe handling; it can
be cut to length. CS are continuous utility straps which can be cut to length on the job site.
Packaged in lightweight (about 40 pounds) cartons.
FINISH: Galvanized. Some products available in Z-MAX; see Corrosion-Resistance, page 6-7.
INSTALLATION: Use all specified fasteners. See General Notes.
Wood shrinkage after strap installation across horizontal wood members may cause strap
to buckle outward. Refer to the applicable code for minimum nail penetration and minimum wood edge and
end distances.
The table shows the maximum allowable loads and the nails required to obtain them.
Fewer nails may be used; reduce the allowable load as shown in footnote #3.
CMST only-Use every other round hole if the wood tends to split. Use round and triangle
holes for comparable MST loads, providing wood does not tend to split.
For lap slice and alternate nailing information, request Technical Bulletin T-CMST.
CODES: See page 12 for Code Listing Key Chart.
48 Nails (Used)
x 4585 lbs 3930 lbs
Allowable Load
Example: CMSTC16 in DF/SP with 48 nails total.
(Half of the nails in each member being connected)
56 Nails (Table)
Available with additional corrosion protection. Check with factory.
Twist straps provide a tension connection between two wood members.
An equal number of right and left hand units are supplied in each carton.
MATERIAL: 16 gauge. FINISH: Galvanized. See Corrosion-Resistance, page 6-7.
INSTALLATION: Use all specified fasteners. See General Notes.
TS should be installed in pairs to reduce eccentricity.
CODES: See page 12 for Code Listing Key Chart.
Model
No.
L
Fasteners
(Total)
Allowable
Loads
(133 160)
TS9
9
8-16d
530
TS12
11
10-16d
665
TS18
17
14-16d
930
TS22
21
18-16d
1215
Code
Ref
170
1.Install half of the fasteners on each end of the
strap to achieve full loads.
2.Loads have been increased for earthquake or wind
loading; no further increase allowed; reduce where
other loads govern.
3.16d sinkers (0.148" dia.x3 may be substituted for
the specified 16d commons at 0.84 of the table loads.
4. Loads are for a single TS.
5. NAILS: 16d 0.162" dia. x 3 long,
See page 16-17 for other nail sizes and information.
TS
Typical TS Installation
158
Straps Ties
CS/CMST Coiled Straps
[close]