Wood Construction Connectors 2006 Catalog [Entire catalog in thumbnail view]Wood Construction Connectors 2006 Catalog [6 pages in thumbnail view]Wood Construction Connectors 2006 Catalog [Page in normal view]Wood Construction Connectors 2006 Catalog [Page in fullsize view]            Wood Construction Connectors 2006 Catalog [First page]    Wood Construction Connectors 2006 Catalog [Previous page]    Page 40 of 195    Wood Construction Connectors 2006 Catalog [Next page]    Wood Construction Connectors 2006 Catalog [Last page]            Wood Construction Connectors 2006 Catalog catalog view Downloadable PDF catalog Wood Construction Connectors 2006 Catalog Flash page flip catalog Wood Construction Connectors 2006 Catalog Visitor statistics of Wood Construction Connectors 2006 Catalog
Zoom in
View extracted text

Page 40 of Wood Construction Connectors 2006 Catalog by Simpson Strong-Tie

41 Anchors PA/HPA Purlin Anchors Wood-to-concrete and -concrete block connectors that satisfy code requirements. The PAs Dual Embedment Line allows installation in concrete or concrete block. MATERIAL: PA 12 gauge; HPA 10 gauge. FINISH: Galvanized. PAs available HDG or Z-MAX. INSTALLATION: Minimum concrete strength is 2000 psi. Use all specified fasteners; some models have extra fastener holes. See General Notes. Purlin Anchor must hook around rebar. Wood splitting may occur when anchor is nailed to wood less than 3 wide. For widths less than 3 ", see PAHD Holdowns for alternate nailing configurations, or PAI. EDGE DISTANCE Minimum concrete edge distance is 5". Minimum concrete block left-to-right edge distance is 20". CONCRETE BLOCK WALL The masonry embedment line on the PA allows for 4" of grout embedment in a standard 8" concrete masonry unit. The minimum wall specifications are: A One #4 vertical rebar, 32" long, 16" each side of anchor; B Two courses of grout filled block above and below the anchor (no cold joints allowed); C A horizontal bond beam with two #4 rebars, 40" long, a maximum of two courses above or below the anchor. All cells grouted with 2000 psi aggregate grout. Grout shall be vibrated per the Code. Rebar quantities, sizes and lengths are minimum requirements and may be increased per any additional wall design requirements. OPTIONS: See LTT and HTT Tension Ties. CODES: See page 12 for Code Listing Key Chart. PA/HPA Purlin to Concrete Wall For I-Joist applications see page 118. Model No. L Fasteners Allowable Tension Loads Masonry Concrete Masonry Concrete (133) (160) (133) (160) Maximum Capacity PA18 18 10-16d 12-16d 1880 2255 2255 2705 PA23 23 16-16d 18-16d 2815 2815 3385 3480 PA28 29 18-16d 20-16d 2815 2815 3590 3590 PA35 35 18-16d 20-16d 2815 2815 3590 3590 2, 40, 121 HPA28 32 24-16d 4845 4845 HPA35 38 27-16d 5420 5420 1 LVL and 3x Ledger PA18 18 10-16d 12-16d 1880 2255 2255 2705 PA23 23 15-16d 18-16d 2815 2815 3385 3480 PA28 29 15-16d 20-16d 2815 2815 3590 3590 PA35 35 15-16d 20-16d 2815 2815 3590 3590 2, 40, 121 HPA28 32 24-16d 4845 4845 HPA35 38 27-16d 5420 5420 4x Ledger PA18 18 8-16d 11-16d 1505 1805 2070 2480 PA23 23 15-16d 17-16d 2815 2815 3195 3480 PA28 29 15-16d 20-16d 2815 2815 3590 3590 PA35 35 15-16d 20-16d 2815 2815 3590 3590 2, 40, 121 HPA28 32 27-16d 4845 4845 HPA35 38 27-16d 5420 5420 Code Ref. The UBC Section 1633.2.8 and IBC 1620.2.1 state: ... Diaphragm to wall anchorage using embedded straps shall have the straps attached to or hooked around the reinforcing steel, or otherwise terminated to effectively transfer forces to the reinforcing steel. Available with additional corrosion protection. Check with factory. 1. Allowable loads are for a horizontal installation into the side of a concrete or masonry wall. 2. Minimum penetration for 16d commons is 1 ". 3. 16d sinkers (0.148" dia. x 3 long) or 10d commons may be substituted for the specified 16d commons at 0.85 of the table loads. 4. Allowable loads have been increased for earthquake or wind load durations with no further increase allowed; reduce where other load durations govern. 5. NAILS: 16d 0.162" dia. x 3 long. See page 16-17 for other nail sizes and information. PA HPA35 PA/HPA Purlin to Concrete Block Wall

[close]
Wood Construction Connectors 2006 Catalog [Entire catalog in thumbnail view]Wood Construction Connectors 2006 Catalog [6 pages in thumbnail view]Wood Construction Connectors 2006 Catalog [Page in normal view]Wood Construction Connectors 2006 Catalog [Page in fullsize view]            Wood Construction Connectors 2006 Catalog [First page]    Wood Construction Connectors 2006 Catalog [Previous page]    Page 40 of 195    Wood Construction Connectors 2006 Catalog [Next page]    Wood Construction Connectors 2006 Catalog [Last page]            Wood Construction Connectors 2006 Catalog catalog view Downloadable PDF catalog Wood Construction Connectors 2006 Catalog Flash page flip catalog Wood Construction Connectors 2006 Catalog Visitor statistics of Wood Construction Connectors 2006 Catalog



All copyrights remain by their owners. Who-sells-it.com is not an official partner of Simpson Strong-Tie.


Home | Latest catalogs | Contact

© 2006-2009 by who-sells-it.com