Page 45 of Wood Construction Connectors 2006 Catalog by Simpson Strong-Tie
46
Caps Bases
AB/ABA/ABE/ABU Adjustable and Standoff Post Bases
Model
No.
Nominal
Post
Size
Material
Dimensions
Fasteners
Allowable Loads (DF/SP)
Base
(Ga)
Strap
(Ga)
W
L
H
HB 6
Anch.
Dia
Post
Uplift (133)
Uplift (160)
Down
(100)
Nails
Nails
Bolts
Nails
Bolts
Qty
Dia
ABA44
4x4
16
16
3
3
6-10d
555
555
6000
5, 41, 121
5, 41, 121
6, 86, 121
8, 36, 91, 121
8, 36, 91, 121
5, 41, 121
9, 121
8, 36, 91, 127
ABE44
4x4
16
16
3
3
6-10d
520
520
6665
ABU44
4x4
16
12
3
3
1
12-16d
2
2200
1800
2200
2160
6665
ABA44R
RGH 4x4
16
16
4
3
6-10d
555
555
8000
ABE44R
RGH 4x4
16
16
4
3
6-10d
400
400
6665
ABE46
4x6
12
16
3
5
8-16d
810
810
7335
ABA46
4x6
14
14
3
5
8-16d
700
700
9435
ABU46
4x6
12
12
3
5
2
12-16d
2
2255
2300
2300
2300
10335
ABE46R
RGH 4x6
12
16
4
5
8-16d
810
810
7335
ABA46R
RGH 4x6
14
14
4
5
8-16d
700
700
12000
ABA66
6x6
14
14
5
5
8-16d
720
720
10665
ABE66
6x6
12
14
5
5
8-16d
900
900
12000
ABU66
6x6
12
10
5
5
1
12-16d
2
2300
2300
2300
2300
12000
ABA66R
RGH 6x6
14
14
6
5
8-16d
720
720
12665
ABE66R
RGH 6x6
12
14
6
5
8-16d
900
900
12000
ABU88R
8x8
14
12
7
2- 7
18-16d
2320
2320
24335
ABU88 4
4
8x8
14
12
7
7
3
2
5
2
2
4
3
7
3
2
3
3
6
2
2
7
7
2- 7
18-16d
2320
2320
24335
RGH
8
Machine
Bolts
Code
Ref.
5, 41, 121
6, 86
9
9
8, 36
8, 36, 127
9, 121
5, 41, 121
1. Uplift loads have been increased for earthquake or wind load durations with
no further increase allowed; reduce where other load durations govern.
2. Downloads may not be increased for short-term loading.
3. Specifier to design concrete for shear capacity.
4. ABU88 and ABU88R may be installed with 8-SDS X3 wood screws for
the same table load.
5. For higher downloads, solidly pack grout under
1" standoff plate before installing into concrete.
Base download on column or concrete,
according to the code.
6. HB dimension is the distance from the bottom
of the post up to the first bolt hole.
7. NAILS: 16d 0.162" dia. x 3 long,
10d 0.148" dia. x 3" long.
See page 16-17 for other nail sizes and
information.
Model
No.
Dimensions
Allowable
Download
(100)
Anchor
Dia.
Fasteners
W
H
AB44
3
2
4065
AB44R
4
2
4065
AB46R
4
2
4165
AB66
5
3
5335
AB66R
6
2
5335
A
8-10d
8-10d
8-10d
8-10d
8-10d
8-10d
B46
3
3
L
3
4
6
5
6
5
4165
2, 40,
82, 121
Code
Ref.
1. Loads may not be increased for short-term loading.
ABE44
Typical ABE46R Installation for
rough lumber (ABE similar)
ABE46,46R,66 and 66R
supplied with washer.
ABA44
(other sizes
similar)
U.S. Patent
5,333,435
Typical AB Installation
ABU88
The AB is an adjustable post base which offers moisture
protection and finished hardware appearance.
Post Bases provide tested capacity. They feature 1" standoff
height above concrete floors, code-required when supporting
permanent structures that are exposed to the weather or water
splash, or in basements. They reduce the potential for decay at
post and column ends.
MATERIAL: AB 12 ga plates; 16 ga base cover;
all others see table.
FINISH: Galvanized. Some products available in Z-MAX;
see Corrosion-Resistance, page 6-7.
INSTALLATION: Use all specified fasteners. See General Notes.
Post bases do not provide adequate resistance to prevent
members from rotating about the base and therefore are
not recommended for non top-supported installations
(such as fences or unbraced carports).
AB supplied as shown; position the post, secure the
easy-access nut, then bend up the fourth side. AB, ABA, ABE and ABU for pre-pour installed anchors.
For epoxy or wedge anchors, select and install according
to anchor manufacturer's recommendations; anchor
diameter shown in table. Install required washer, which
is not included for ABAs.
See Simpson Anchor Systems for tested, load-rated
anchors and request T-ANCHORSPEC for more
information.
CODES: See page 12 for Code Listing Key Chart.
AB
ABU44
(other sizes similar)
Additional standoff bases are on page 187.
Anchor Bolt
per Designer,
or consult
T-ANCHORSPEC
catalog
Available with additional corrosion protection. Check with factory.
[close]