Page 51 of Wood Construction Connectors 2006 Catalog by Simpson Strong-Tie
LPC
AC
52
Caps Bases
AC/LPC/LCE Post Caps
PC/EPC Post Caps
PC
Typical PC
Post Cap
Installation
Typical EPC
End Post Cap
Installation
A custom connection for post-beam combinations at medium
design loads.
MATERIAL: PC 12 gauge; PC-16 16 gauge
FINISH: Galvanized. Some products available in Z-MAX;
see Corrosion-Resistance, page 6-7.
INSTALLATION: Use all specified fasteners; see General Notes.
If pilot holes are bolted, no additional load is achieved.
OPTIONS: For end conditions, specify EPC post caps, providing
dimensions are in accordance with table; see illustration.
Some PC and EPC models are available in rough sizes.
For heavy duty applications, see CC and CCQ series.
CODES: See page 12 for Code Listing Key Chart.
Model
No.
Post
Size
Dimensions
Fasteners Each Side
Allowable Loads
W1
W2
L1
L2
L3
Surfaces
Uplift PC/EPC
Lateral 2
Post
Beam
PC
Beam
EPC
(133)
(160)
PC
(133/160)
EPC
(133/160)
PC44-16
4x 4
3
3
2
7
4-16d 6-16d 4-16d
1000
1000
925
1000
PC44
4x 4
3
3
2
7
4-16d 6-16d 4-16d
1470
1700
925
1070
PC46-16
4x 6
3
5
2
9
4-16d 6-16d 4-16d
1000
1000
925
1000
PC46
4x 6
3
5
2
9
4-16d 6-16d 4-16d
1470
1700
925
1070
PC48-16
4x 8
3
7
2
11
4-16d 8-16d 6-16d
1000
1000
1475
1285
PC48
4x 8
3
7
2
11
4-16d 8-16d 6-16d
1470
1700
2075
1610
PC64-16
4x 6
5
3
4
7
4-16d 6-16d 4-16d
1000
1000
925
1000
PC64
4x 6
5
3
4
7
4-16d 6-16d 4-16d
1470
1700
925
1070
PC66-16
6x 6
5
5
4
9
4-16d 6-16d 6-16d
1000
1000
925
1285
PC66
6x 6
5
5
4
9
4-16d 6-16d 6-16d
1470
1700
925
1610
PC68
6x 8
5
7
4
11
4-16d 8-16d 6-16d
1470
1700
2075
1610
PC84
4x 8
7
3
6
7
4-16d 6-16d 6-16d
1470
1700
925
1610
PC86
6x 8
7
5
6
9
4-16d 6-16d 6-16d
1470
1700
925
1610
PC88
8x 8
7
7
6
11
11
13
13
15
15
11
11
13
13
15
11
13
15
11
4-16d 8-16d 6-16d
1470
1700
2075
1610
Min
Code
Ref.
7, 90,
121
1. Allowable loads have been increased for
earthquake or wind load durations with no
further increase allowed; reduce where other
load durations govern.
2. Lateral loads are in the direction parallel to
the beam.
3. Allowable loads are for nails only.
4.Uplift loads do not apply to splice conditions.
5.Spliced conditions must be detailed by
the Designer to transfer tension loads
between spliced members by means other
than the post cap.
4. NAILS: 16d 0.162" dia. x 3 long,
See page 16-17 for other nail sizes and
information.
Model
No.
Dimensions
Fasteners
Allowable Loads
(133 160) 1
W
L
Beam
Post
Uplift
Lateral
AC4 (Min)
3
6
12-16d
8-16d
1430
715
AC4 (Max)
3
6
14-16d
14-16d
2500
1070
AC4R (Min)
4
7
12-16d
8-16d
1430
715
AC4R (Max)
4
7
14-16d
14-16d
2500
1070
ACE4 (Min)
4
8-16d
6-16d
1070
715
ACE4 (Max)
4
10-16d
10-16d
1785
1070
AC6 (Min)
5
8
12-16d
8-16d
8-16d
1430
715
AC6 (Max)
5
8
14-16d
14-16d
2500
1070
AC6R (Min)
6
9
12-16d
1430
715
AC6R (Max)
6
9
14-16d
14-16d
2500
1070
ACE6 (Min)
6
8-16d
6-16d
1070
715
ACE6 (Max)
6
10-16d
10-16d
1785
1070
LPC4
3
3
8-10d
8-10d
760
325
LPC6
5
5
8-10d
8-10d
915
490
Code
Ref.
LCE4
5
14-16d
10-16d
1880
1425
N
Total
o.
4, 37, 87, 121
37
4, 37, 87, 121
160
4, 37, 87, 121
37
4, 37, 87, 121
7, 121
8, 36, 121
1. Allowable loads have been increased for earthquake
or wind load durations with no further increase
allowed; reduce where other load durations govern.
2. Loads apply only when used in pairs.
Typical ACE
Installation
Typical LCE4 Installation
(For 4x or 6x lumber)
The LCE4s universal design provides high capacity while eliminating the need for rights and
lefts. For use with 4x or 6x lumber. LPC Adjustable design allows greater connection versatility.
MATERIAL: LCE4 20 ga; AC, ACE, LPC4 18 ga; LPC6 16 ga
FINISH: Galvanized. Some products available in Z-MAX and stainless steel;
see Corrosion-Resistance, page 6-7.
INSTALLATION: Use all specified fasteners. See General Notes.
Install all models in pairs. LPC 2 beams may be used if 10dx1 nails are
substituted for 10d commons.
CODES: See page 12 for Code Listing Key Chart.
3. LPC lateral load is in the direction parallel to the beam.
4.MIN nailing quantity and load values fill all round holes;
MAX nailing quantities and load values fill round and triangle holes.
5.Uplift loads do not apply to splice conditions.
6. Spliced conditions must be detailed by the
Designer to transfer tension loads between
spliced members by means other than the post cap.
7. NAILS: 16d 0.162" dia. x 3 long,
10d 0.148" dia. x 3" long. See page 16-17 for
other nail sizes and information.
Available with additional corrosion protection. Check with factory.
Available with additional corrosion protection. Check with factory.
[close]