Page 62 of Wood Construction Connectors 2006 Catalog by Simpson Strong-Tie
63
Shearwall
STRONG-WALL SHEARWALL
RAISED FLOOR (-RF)
Raised Floor walls are designed and tested for installation on top of raised
wood floor systems. All 2nd Floor Applications must use the Raised Floor
Models. Raised Floor walls are compatible with both solid sawn lumber
and I-joist floor systems. Simpson SDS screws pre-installed in both the
top and bottom of the wall allow for fast installation to the top plate and
floor framing elements.
When framing conditions necessitate this application,
only the HUSC46 may be used with the Strong-Wall
Shearwall for light duty door and window headers. With
face nailing closer to the center of the carrying member
and the double shear nailing feature, an HUSC46 hanger
will achieve the loads listed in the Face Mount Hanger
tables. Application is limited to the HUSC46.
See page 69 for details.
NOTE: When nailing into the carrying members end
grain, the allowable load is 0.67 of the table load.
CODE REF.: 1, 84, 121, 140
CODES: See page 12 for Code Listing Key Chart.
The building designer shall verify that these details are consistent with the complete load path requirements of the structure.
HUSC46
Typical Installation of HUSC46
Naming Scheme:
SW24x8-RF
Strong-Wall
Raised Floor
Width
(in.)
Nominal
Height
(ft.)
NOTE: The Engineer of Record is responsible for concrete design.
Additional 2x4 King Studs
may be required for
compression force from
Strong-Wall above.
See Structural Details
available on our website.
NOTE:
Cut out subfloor for
end post bearing plates.
Additional bearing
plates available for
1 subfloor.
SW-TUD1KT
STRONG-WALL SHEARWALL FOR
2nd FLOOR APPLICATIONS!
Raised Floor (-RF) walls are code listed for use on the second floor of
two-story wood light-frame construction. Simpson Strong-Tie recommends
the Simpson Takeup Device, (SW-TUD1KT), be used at the 2nd floor to
compensate for wood shrinkage and settlement due to dead load.
NOTE FOR
STANDARD AND
RAISED FLOOR
WALLS:
Walls may also
be used in 2x6
wall framing.
Install sheathing
side at exterior
wall line and add
furring to interior
framing side.
HUSC Concealed Flange Face Mount Hanger
[close]