Page 65 of Wood Construction Connectors 2006 Catalog by Simpson Strong-Tie
66
Shearwall
STRONG-WALL SHEARWALL
The building designer shall verify that these details are consistent with the complete load path requirements of the structure.
GARAGE PORTAL SYSTEMS
1. The height of the garage curb above the
garage slab is critical for rough header
opening on portal walls.
2. One 1/2" shim is provided with Garage
Portal walls.
22" Garage Portal
Model No.
W
(in)
H
(in)
T
(in)
Number of
Fasteners
in Top
of Wall
Allow.
Shear V
Load (lb)
for Portal
System 5
Drift at
Allow.
Shear V
(in)
Allow.
Shear V
Load
(lb/ft)
Number
of
Mudsill
Anchors 6
Holdown 2
Anchor
Bolts
Wall
Weight
(lbs)
Code
Ref.
34, 101
34, 101
34, 60,101,137
34, 60,101,137
SW16x7x4
SW16x7x6
SW16x8x4
SW16x8x6
SW22x7x4
SW22x7x6
SW22x8x4
SW22x8x6
16
16
16
16
22
22
22
22
4
5
4
5
4
5
4
5
2-
2-
2-
2-
2-
2-
2-
2-
2800
2800
2490
2490
4820
4820
3990
3990
1050
1050
935
935
1315
1315
1090
1090
90
112
95
120
95
117
105
130
.367
.367
.420
.420
.369
.369
.446
.446
8-SDS x6
8-SDS x6
8-SDS x6
8-SDS x6
10-SDS x6
10-SDS x6
10-SDS x6
10-SDS x6
2-SSTB28
2-SSTB28
2-SSTB28
2-SSTB28
2-SSTB28
2-SSTB28
2-SSTB28
2-SSTB28
78
78
90
90
78
78
90
90
1. For plywood shear panel, add P to model name
(e.g. SW24x8P), and multiply the table loads by 0.88.
2. For two-pour bolted applications, use the SSTB34.
3. Recommended header moisture content is 19% or less at
time of installation.
4. A double wall garage portal system consists of 2 walls with a
header spanning over the top and connected as shown.
5. SW16 and SW22 walls may be combined. The capacity of
the combined system shall be the sum of the Single Wall
Garage Portal capacities.
6. Recommended minimum 5/8"x12" mudsill anchor.
7. The minimum header sizes listed are the minimum required
for lateral rigidity of the portal system. Larger headers
may be required due to vertical loading.
8. Portal walls may be installed with sheathing facing
inside or outside.
9. Maximum shim height between Strong-Wall Portal
Walls and header is ". Shims of greater thickness
will result in load reductions.
10. See allowable vertical load table on page 64 for
Strong-Wall maximum compression and tension
capacities.
11.Capacities must be reduced as limited by anchor bolt
capacities for installations on CMU.
DOUBLE WALL GARAGE PORTAL 4
16" Garage Portal
Alternate Exterior Installation
For easy electrical installation
position wall with sheathing inside garage.
Garage Portal systems provide increased lateral resistance over site-built shearwalls in locations
where space is at a premium. Portal walls shall be installed with a minimum 12" nominal deep
header for adequate shear nailing. Because the portal walls and header are tested as a system,
the resulting portal frame offers superior engineered performance over site-built walls.
CODES: See page 12 for Code Listing Key Chart.
Model
No.
H
Curb
Without
Shim
With
Shim
SW16x7x4
6"
7'
7'- "
SW22x7x4
SW16x7x6
7'-1"
7'-1 "
SW22x7x6
7"
SW16x8x4
6"
8'
8'- "
SW22x8x4
SW16x8x6
8'-1"
8'-1 "
SW22x8x6
7"
GARAGE HEADER
ROUGH OPENING HEIGHT
Header shall be a single member with width
matching wall thickness x 12" min. nominal depth.
*
NOTE: The
Engineer of
Record is
responsible
for concrete
design.
Naming Scheme:
SW16x7x4
Strong-Wall
Width
(in.)
Nominal
Height
(ft.)
Nominal Wall
Thickness
(in.)
NOTE FOR GARAGE PORTAL WALLS:
Cripple walls over the garage header shall be designed by Engineer of Record.
Drilling or cutting
holes in Strong-Wall
Shearwalls is not
allowed except as
shown in the
Allowable Hole Chart
attached to each wall.
[close]