Page 65 of 195 ![]() |
![]() View extracted text
Page 65 of Wood Construction Connectors 2006 Catalog by Simpson Strong-Tie66 Shearwall STRONG-WALL SHEARWALL The building designer shall verify that these details are consistent with the complete load path requirements of the structure. GARAGE PORTAL SYSTEMS 1. The height of the garage curb above the garage slab is critical for rough header opening on portal walls. 2. One 1/2" shim is provided with Garage Portal walls. 22" Garage Portal Model No. W (in) H (in) T (in) Number of Fasteners in Top of Wall Allow. Shear V Load (lb) for Portal System 5 Drift at Allow. Shear V (in) Allow. Shear V Load (lb/ft) Number of Mudsill Anchors 6 Holdown 2 Anchor Bolts Wall Weight (lbs) Code Ref. 34, 101 34, 101 34, 60,101,137 34, 60,101,137 SW16x7x4 SW16x7x6 SW16x8x4 SW16x8x6 SW22x7x4 SW22x7x6 SW22x8x4 SW22x8x6 16 16 16 16 22 22 22 22 4 5 4 5 4 5 4 5 2- 2- 2- 2- 2- 2- 2- 2- 2800 2800 2490 2490 4820 4820 3990 3990 1050 1050 935 935 1315 1315 1090 1090 90 112 95 120 95 117 105 130 .367 .367 .420 .420 .369 .369 .446 .446 8-SDS x6 8-SDS x6 8-SDS x6 8-SDS x6 10-SDS x6 10-SDS x6 10-SDS x6 10-SDS x6 2-SSTB28 2-SSTB28 2-SSTB28 2-SSTB28 2-SSTB28 2-SSTB28 2-SSTB28 2-SSTB28 78 78 90 90 78 78 90 90 1. For plywood shear panel, add P to model name (e.g. SW24x8P), and multiply the table loads by 0.88. 2. For two-pour bolted applications, use the SSTB34. 3. Recommended header moisture content is 19% or less at time of installation. 4. A double wall garage portal system consists of 2 walls with a header spanning over the top and connected as shown. 5. SW16 and SW22 walls may be combined. The capacity of the combined system shall be the sum of the Single Wall Garage Portal capacities. 6. Recommended minimum 5/8"x12" mudsill anchor. 7. The minimum header sizes listed are the minimum required for lateral rigidity of the portal system. Larger headers may be required due to vertical loading. 8. Portal walls may be installed with sheathing facing inside or outside. 9. Maximum shim height between Strong-Wall Portal Walls and header is ". Shims of greater thickness will result in load reductions. 10. See allowable vertical load table on page 64 for Strong-Wall maximum compression and tension capacities. 11.Capacities must be reduced as limited by anchor bolt capacities for installations on CMU. DOUBLE WALL GARAGE PORTAL 4 16" Garage Portal Alternate Exterior Installation For easy electrical installation position wall with sheathing inside garage. Garage Portal systems provide increased lateral resistance over site-built shearwalls in locations where space is at a premium. Portal walls shall be installed with a minimum 12" nominal deep header for adequate shear nailing. Because the portal walls and header are tested as a system, the resulting portal frame offers superior engineered performance over site-built walls. CODES: See page 12 for Code Listing Key Chart. Model No. H Curb Without Shim With Shim SW16x7x4 6" 7' 7'- " SW22x7x4 SW16x7x6 7'-1" 7'-1 " SW22x7x6 7" SW16x8x4 6" 8' 8'- " SW22x8x4 SW16x8x6 8'-1" 8'-1 " SW22x8x6 7" GARAGE HEADER ROUGH OPENING HEIGHT Header shall be a single member with width matching wall thickness x 12" min. nominal depth. * NOTE: The Engineer of Record is responsible for concrete design. Naming Scheme: SW16x7x4 Strong-Wall Width (in.) Nominal Height (ft.) Nominal Wall Thickness (in.) NOTE FOR GARAGE PORTAL WALLS: Cripple walls over the garage header shall be designed by Engineer of Record. Drilling or cutting holes in Strong-Wall Shearwalls is not allowed except as shown in the Allowable Hole Chart attached to each wall.[close] |
Page 65 of 195 ![]() |
All Copyrights are and remain property of Simpson Strong-Tie. Who-sells-it.com is not an official partner of Simpson Strong-Tie. |